TELTONIKA FMC13A Advanced LTE Terminal User Manual

June 9, 2024
teltonika

FMC13A
ADVANCED LTE TERMINAL WITH
FLEXIBLE INPUTS CONFIGURATION

KNOW YOUR DEVICE

TELTONIKA FMC13A Advanced LTE Terminal - TDEVICE

PINOUT

Pin number Pin name Description
1 VCC (10-30)V DC (+) Power supply (10-30 V DC)
2 DOUT 3 Digital output, channel

3. Open collector output. Max. 0,5 A DC
3| DIN 3 / AIN 2| Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3
4| DIN 2-N / AIN 1| Digital input, channel 2, Negative input (ground sense), Analog input, channel 1, Input range: 0-30 VDC
5| DIN 1| Digital input, channel 1
6| INPUT 6| TX EXT (LVCAN – TX)
7| GND (-)| Ground pin. (10-30) V DC(—)
8| DOUT 1| Digital output, channel
1. Open collector output. Max. 0,5 A DC
9| DOUT 2| Digital output, channel
2. Open collector output. Max. 0,5 A DC
10| 1WIRE POWER| +3,8 V output for 1-Wire devices
11| 1 WIRE DATA| Data for 1-Wire devices
12| INPUT 5V| RX EXT (LVCAN – RX)

TELTONIKA FMC13A Advanced LTE Terminal - DEVICE1

WIRING SCHEME

TELTONIKA FMC13A Advanced LTE Terminal - SCHEME

SET UP YOUR DEVICE

HOW TO INSERT MICRO-SIM CARD AND CONNECT THE BATTERY

TELTONIKA FMC13A Advanced LTE Terminal - Setup

  1.  COVER REMOVAL
    You will receive your device partly closed. Gently remove top and bottom covers.

  2. MICRO-SIM CARD INSERT
    Insert SIM card as shown with PIN request disabled or read our Wiki1 how to enter it later in Teltonika Configurator 2  . Make sure that Micro-SIM card cut-off corner  is pointing outward from slot. SIM slot 1 is closer to PCB, SIM slot 2 is the top one.
    1 wiki.teltonika-gps.com/view/ 
    FMC13A_Security_info
    2  wiki.teltonika-gps.com/view/ 
    Teltonika_Configurator

  3. BATTERY CONNECTION
    Connect battery as shown to device. Position the battery in place where it does not obstruct other components.

  4. ATTACHING COVER BACK
    After configuration, see “PC Connection (Windows)”, attach device top and bottom cover back and press them twice to the full closure. Make sure that product casing is closed correctly.

PC CONNECTION (WINDOWS)

  1. Power-up FMC13A with DC voltage (10 – 30 V) power supply using supplied power cable. LED’s should start blinking, see “LED indications”.

  2. Connect device to computer using Micro-USB cable or Bluetooth connection:
    • Using Micro-USB cable
    • You will need to install USB drivers, see “How to install USB drivers (Windows)”
    • Using Bluetooth
    • FMC13A Bluetooth is enabled by default. Turn on Bluetooth on your PC, then select Add Bluetooth or other device > Bluetooth. Choose your device named – “FMC13A_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.

  3. You are now ready to use the device on your computer.

HOW TO INSTALL USB DRIVERS (WINDOWS)

  1. Please download COM port drivers from here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
  5.  Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

CONFIGURATION

At first FMC13A device will have default factory settings set. These settings should be changed according to the users needs. Main configuration can be performed via Teltonika Configurator¹ software. Get the latest Configurator version from here². Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.
1  wiki.teltonika-gps.com/view/Teltonika_Configurator
2  wiki.teltonika-gps.com/view/Teltonika_Configurator_versions

MS .Net requirements

Operating system MS .NET Framework version Version Links

Windows Vista
Windows 7
Windows 8.1
Windows 10| MS .NET Framework 4.6.2| 32 and 64 bit| www.microsoft.com¹

1  https://dotnet.microsoft.com/en-us/download/dotnet-framework/net462

TELTONIKA FMC13A Advanced LTE Terminal - App

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking in the right bottom corner.

TELTONIKA FMC13A Advanced LTE Terminal - icon1

Configuration process begins by pressing on connected device.

TELTONIKA FMC13A Advanced LTE Terminal - SCHEME1

After connection to Configurator Status window will be displayed.

Various Status window¹ tabs display information about GNSS², GSM³, I/O4, Maintenance5 and etc. FMC13A has one user editable profile, which can be loaded and saved to the device.
After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

| Load from device – loads configuration from device.
---|---
| Save to device – saves configuration to device.
| Load from file – loads configuration from file.
| Save to file – saves configuration to file.
| Update firmware – updates firmware on device.
| Read records – reads records from the device.
| Reboot device – restarts device.
| Reset configuration – sets device configuration to default.

Most important configurator section is GPRS – where all your server and GPRS settings6 can be configured and Data Acquisition7 – where data acquiring parameters can be
configured. More details about FMC13A configuration using Configurator can be found in our Wiki8.

  1. wiki.teltonika-gps.com/view/FMC13A_Status_info
  2. wiki.teltonika-gps.com/view/FMC13A_Status_info#GNSS_Info
  3. wiki.teltonika-gps.com/view/FMC13A_Status_info#GSM_Info
  4. wiki.teltonika-gps.com/view/FMC13A_Status_info#I.2FO_Info
  5. wiki.teltonika-gps.com/view/FMC13A_Status_info#Maintenance
  6. wiki.teltonika-gps.com/view/FMC13A_GPRS_settings
  7. wiki.teltonika-gps.com/view/FMC13A_Data_acquisition_settings
  8. wiki.teltonika-gps.com/view/FMC13A_Configurationn

QUICK SMS CONFIGURATION

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:

TELTONIKA FMC13A Advanced LTE Terminal - SMS
CONFIGURATION

Note: Before SMS text, two space symbols should be inserted.

GPRS SETTINGS:

  1. 2001 – APN
  2. 2002 – APN username (if there are no APN username, empty field should be left)
  3. 2003 – APN password (if there are no APN password, empty field should be left)TELTONIKA FMC13A Advanced LTE Terminal - SMS CONFIGURATION1 SERVER SETTINGS:
  4. 2004 – Domain
  5. 2005 – Port
  6. 2006 – Data sending protocol (0 – TCP, 1 – UDP)

DEFAULT CONFIGURATION SETTINGS

MOVEMENT AND IGNITION DETECTION:

| VEHICLE MOVEMENT
will be detected by accelerometer
---|---
| IGNITION WILL BE DETECTED
by vehicle power voltage between 13,2 – 30 V

DEVICE MAKES A RECORD ON MOVING IF ONE OF THESE EVENTS HAPPEN:

| 300
seconds passes
---|---
| VEHICLE TURNS10
degrees
| VEHICLE DRIVES
100 meters
| SPEED DIFFERENCE
between last coordinate and current position is greater than 10 km/h

DEVICE MAKES A RECORD ON STOP IF:

| 1 HOUR PASSES
while vehicle is stationary and ignition is off
---|---

RECORDS SENDING TO SERVER:

| IF DEVICE HAS MADE A RECORD
it is sent to the server every 120 seconds
---|---

After successful SMS configuration, FMC13A device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator1 or SMS parameters2.

  1. wiki.teltonika-gps.com/view/Teltonika_Configurator
  2. wiki.teltonika-gps.com/view/Template:FMB_Device_Family_Parameter_list

MOUNTING RECOMMENDATIONS

CONNECTING WIRES

  • Wires should be connected while the module is not plugged in.
  • Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
  • There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
  • If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
  • Wires cannot be connected to the board computers or control units.

CONNECTING POWER SOURCE

  • Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the
    car model, this may happen in 5 to 30 minutes period.

  • When the module is connected, measure the voltage again to make sure it did not decrease.

  • It is recommended to connect to the main power cable in the fuse box.

  • 3 A, 125 V external fuse shall be used.

CONNECTING IGNITION WIRE

  • Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
  • Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
  • Check if power is still available when you turn off any of vehicles devices.
  • Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on,
    may be chosen.

CONNECTING GROUND WIRE

  • Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
  • If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
  • For better contact scrub paint from the spot where loop is going to be connected.

LED INDICATIONS

NAVIGATION LED INDICATIONS

Behaviour Meaning
Permanently switched on GNSS signal is not received
Blinking every second Normal mode, GNSS is working
Off GNSS is turned off because:

Device is not working or Device is in sleep mode
Blinking fast constantly| Device firmware is being flashed

STATUS LED INDICATIONS

Behaviour Meaning
Blinking every second Normal mode
Blinking every two seconds Sleep mode
Blinking fast for a short time Modem activity
Off Device is not working or Device is in boot mode

BASIC CHARACTERISTICS

Module

Name| FMC13A-QBIB0: Quectel EG91-NA with Teltonika TM2500
Technology| LTE(CAT1)/UMTS/GNSS/BLUETOOTH
GNSS
GNSS| GPS, GLONASS, GALILEO, BEIDOU, QZSS, AGPS
Receiver| 33 channel
Tracking sensitivity| -165 dBM
Position Accuracy| < 2.5 CEP
Velocity Accuracy| < 0.1 m/s (within +/- 15% error)
Hot start| < 1 s
Warm start| < 25 s
Cold start| < 35 s
Celluar
Technology| LTE Cat 1, UMTS
3G bands| WCDMA: B2/B4/B5
4G bands| LTE FDD: B2/B4/B5/B12/B13
Data transfer| LTE: LTE FDD: Max 10Mbps (DL)/Max 5Mbps (UL)
UMTS: WCDMA: Max 384Kbps (DL)/Max 384 Kbps (UL)
Transmit power| Class 3 for LTE-FDD: 23±1dBm
Class 3 for WCDMA: 23.5±1dBm
Data support| SMS (text/data)
Power
Input voltage range| 10 – 30 V DC with overvoltage protection
Internal Back-up battery| 170 mAh Li-Po battery 3.7 V (0.63 Wh)
Internal fuse| 3 A, 125 V
Power Consumption| At 12V < 3 mA (Ultra Deep Sleep)
At 12V < 5 mA (Deep Sleep)
At 12V < 16 mA (Online Deep Sleep)
At 12V < 18 mA (GPS Sleep)
At 12V < 33 mA (nominal with no load)
At 12V < 250mA Max. (with full Load / Peak)
Bluetooth
Specification| 4.0 + LE
Supported peripherals| Temperature and Humidity sensor, OBDI dongle, Inateck Barcode Scanner, Universal BLE sensors support
Interface
Connection| 3
Negative Inputs| 1 (Digital Input 2)
Impulse Inputs| 2 (Digital Input 1, Digital Input 2)
Digital Outputs| 3
Analog Inputs| 2
CAN Adapter inputs| 1
1-Wire| 1
GNSS antenna| Internal High Gain
Cellular antenna USB| Internal High Gain
2.0 Micro-USB
LED indication| 2 status LED lights
SIM| Micro-SIM + eSIM
Memory| 128MB internal flash memory
Physical specification
Dimensions| 77 x 62 x 20 mm (L x W x H)
Operating Environment
Operating temperature (without battery)| -20 °C to +85°C
Storage temperature (without battery)| -20 °C to +85°C
Operating temperature (with battery)| 0 °C to +45 °C
Storage temperature (with battery)| -20 °C to +45 °C for 1 month
-20 °C to +35 °C for 6 months
Operating humidity| 5% to 95% non-condensing
Ingress Protection Rating| IP41
Battery charge temperature Battery discharge temperature| 0 °C to +45 °C
-20 °C to +60 °C
Battery storage temperature| -20 °C to +45 °C for 1 month
-20 °C to +35 °C for 6 months
Features
Sensors| Accelerometer
Scenarios| Green Driving, Over Speeding detection, GNSS Fuel Counter, DOUT Control Via Call, Excessive Idling detection, Immobilizer, iButton Read Notification, Unplug detection, Towing detection, Crash detection, Auto Geofence, Manual Geofence, Trip, Ground Sense
Sleep modes| GPS Sleep, Online Deep Sleep, Deep Sleep, Ultra Deep Sleep
Configuration and firmware update| FOTA Web, FOTA, Teltonika Configurator (USB, Bluetooth), FMBT mobile application (Configuration)
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control, Debug
Time Synchronization Fuel monitoring| GPS, NITZ, NTP
LLS (Analog), LV-CAN200, ALLCAN300, OBDII dongle, CANCONTROL
Ignition detection| Digital Input 1, Accelerometer, External Power Voltage, Engine RPM (CAN Adapters, OBDII dongle)

ELECTRICAL CHARACTERISTICS

Characteristic description Value
Supply voltage Min.
Supply Voltage (Recommended Operating Conditions) 10

Digital output (open drain grade)
Drain current (Digital Output OFF)| | | 120| μA
Drain current (Digital Output ON, Recommended
Operating Conditions)| | 0.1| 0.5| A
Static Drain-Source resistance (Digital Output ON)| | 400| 600| mΩ
Digital input
Input resistance (DIN1)| | 47| | kΩ
Input resistance (DIN2)| | 38.45| | kΩ
Input resistance (DIN3)| | 150| | kΩ
Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V
Input Voltage threshold (DIN1)| | 7.5| | V
Input Voltage threshold (DIN2)| | 2.5| | V
Input Voltage threshold (DIN3)| | 2.5| | V
Analog input
Input voltage (Recommended Operating Conditions), Range 1| 0| | | V
Input resistance, Range 1| | 38.45| | kΩ
Measurement error on 12V, Range 1| | 0.9| | %
Additional error on 12 V, Range 1| | 108| | mV
Measurement error on 30 V, Range 1| | 0.33| | %
Additional error on 30 V, Range 1| | 88| | mV
Input Voltage (Recommended Operating Conditions), Range 2| 0| | | V
Input resistance, Range 2| | 150| | kΩ
Measurement error on 12 V, Range 2| | 0.9| | %
Additional error on 12 V, Range 2| | 108| | mV
Measurement error on 30 V, Range 2| | 0.33| | %
Additional error on 30 V, Range 2| | 88| | mV
Output supply voltage 1-wire
Supply voltage| 4.5| | 4.7| V
Output inner resistance| | 7| | Ω
Output current (Uout  > 3.0 V)| | 30| | mA
Short circuit current (Uout= 0)| | 75| | mA
Negative input
Input resistance| 38.45| | | kΩ
Input voltage (Recommended Operating Conditions)| 0| | Supply voltage| V
Input voltage threshold| | 0.5| | V
Sink current| | | 180| nA

SAFETY INFORMATION

  • This message contains information on how to operate FMC13A safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!
  • The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10..+30 V DC.
  • To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
  • When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
  • Before unmounting the device from the vehicle, the 2×6 connector must be disconnected. The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard.
  • The device FMC13A is not designed as a navigational device for boats.
  • Before unmounting the device from vehicle, ignition MUST be OFF.

| Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or he isolation is damaged, DO NOT touch the device before unplugging the power supply.
---|---
| All wireless data transferring devices produce interference that may affect other devices which are laced nearby.
| The device must be connected only by qualified personnel.
| The device must be firmly fastened in a predefined location.
| The programming must be performed using a PC with autonomic power supply.
| Installation and/or handling during a lightning storm is prohibited.
| The device is susceptible to water and humidity.
| CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
****| Battery should not be disposed of with general household waste. Bring damaged or worn-out batteries to your local recycling center or dispose them to battery recycle bin found in stores.
| This sign on the package means that it is necessary to read the User ‘s Manual before your start using the device. Full User ‘s Manual version can be found in our Wiki1.

1  https://wiki.teltonika.lt/view/FMC13A_RoHS

This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste.

FCC ID:2A3HUFMC13A.

  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.
  • Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
  • This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. To comply with FCC RF Exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for the transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

IC NOTICE
This device complies with Industry Canada licenseexempt RSS standard(s).
Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.
    This Class B digital apparatus complies with Canadian ICES-003.

IC: 28804-FMC13A.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. To comply with RSS-102 RF Exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for the transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

CHECK ALL CERTIFICATES
All newest certificates may be found in our Wiki2.
2 wiki.teltonika-gps.com/view/FMC13ACertification%26_Approvals

WARRANTY

TELTONIKA guarantees its products to be free of any manufacturing defects for a period of 24 months. With additional agreement we can agree on a different warranty period, for more detailed information please contact our sales manager.
Contact us teltonika-iot-group.com/about-us/contacts/
All batteries carry a reduced 6 month warranty period.
If a product should fail within this specific warranty time, the product can be:

  • Repaired
  • Replaced with a new product
  • Replaced with an equivalent repaired product fulfilling the same functionality
  • TELTONIKA can also repair products that are out of warranty at an agreed cost.

WARRANTY DISCLAIMER

TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND EXPERIENCE. ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED.
ALSO EXCLUDED FROM THIS LIMITED WARRANTY ARE ANY AND ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR REVENUE, LOSS OF TIME, INCONVENIENCE OR ANY OTHER ECONOMIC LOSS.
More information can be found at teltonika-iot-group.com/about-us/policies- certificates/warranty-repair

Quick Manual v1.9 // FMC13A

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>