CentoLight Scenic C1012 12x10W RGBW 4 In 1 LED PAR Light with 25 Degree Beam for Indoor Use User Manual
- June 9, 2024
- CentoLight
Table of Contents
- CentoLight Scenic C1012 12x10W RGBW 4 In 1 LED PAR Light with 25 Degree
- BEFORE YOU BEGIN
- SAFETY INSTRUCTIONS
- MOUNTING AND RIGGING
- INTRODUCTION
- Product Setup
- Menu Operation
- Troubleshooting
- Specification
- Warranty And Service
- Warning
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CentoLight Scenic C1012 12x10W RGBW 4 In 1 LED PAR Light with 25 Degree
Beam for Indoor Use
Scenic C1012
12x10W RGBW 4in1 LED PAR with 25° beam for indoor use PAR per uso interno
con 12 LED da 10W RGBW 4in1 e apertura del fascio a 25°Carefully read this
manual and properly take care of it
Dear customer,
First of all thanks for purchasing a CENTOLIGHT® product. Our mission is to
satisfy all possible needs of light designers and professionals of
entertainment lighting, by offering a wide range of products based on the
latest technologies. We hope you will be satisfied with this fixture and, if
you want to collaborate, we are looking for feedback from you about product
operation and possible improvements to be introduced in the next future. Go to
our website www.centolight. com and send an e-mail
with your opinion; this will help us to build equipment ever closer to the
professional’s real requirements.
BEFORE YOU BEGIN
Thank you for purchasing SCENIC C1012. Enjoy your new equipment and make sure to read this manual carefully before operation! This user manual is made to provide both an overview of controls, as well as information on how to use them.
What is included
Package include:
- 1x CENTOLIGHT SCENIC C1012 PAR light
- 1x 1m (40in ca.) Powercon to Europlug power cable
- 1X 2m (79in ca.) DMX Cable 3-pin XLR-M to 3-pin XLR-F
- This User Manual
ATTENTION: Packaging bag is not a toy! Keep out of reach of children!!! Keep in a safe place the original packaging material for future use.
Unpacking Instructions
Carefully unpack the product immediately and check the content to make sure
all the parts are in the package and are in good condition. If the box or the
contents (the product and included accessories) appear damaged from shipping,
or show signs of mishandling, notify the carrier or dealer/seller imme-
diately. In addition, keep the box and contents for inspection. If the fixture
must be returned to the manufacturer, it is important that it is returned in
the original manufacturer box and packing. Please do not take any action
without first contacting your dealer or getting in touch with our after-sales
support service (visit www.centolight.com for details).
Accessories
CENTOLIGHT can supply a wide range of quality accessories that you can use
with your SCENIC Series equipment, like Cables, Splitters, DMX controllers,
Consumables, and a wide range of other fixtures. All products in our catalogue
has been long tested with this device, so we recom-mend you to use Genuine
CENTOLIGHT Accessories and Parts. Ask your CENTOLIGHT dealer or check out our
website www.centolight.com for any accessories
you could need to ensure best performance of the product.
Disclaimer
The information and specifications contained in this User Manual are subject to
change without notice. CENTOLIGHT assumes no responsibility or liability for
any errors or omissions and reserves the right to revise or to create this
manual at any time.
Copyright© 2021 CENTOLIGHT. All rights reserved.
SAFETY INSTRUCTIONS
- Read these instructions
- Keep these instructions
- Heed all warning
- Follow all instructions
Symbols Meaning
- The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even under the normal operating conditions, which may be sufficient to constitute the risk of electric shock or death.
- The symbol is used to describe important installation or configuration problems. Not following advice and information on how to avoid such problems may lead to product malfunction.
- This symbol indicates a protective grounding terminal.
WARNING: Describes precautions that should be observed to prevent the danger of injury or death to the operator.
- To protect the environment, please try to recycle packing material and exhausted consumables as much as possible.
- This symbol indicates that the fixture is intended to indoor use only. Keep the machine dry and do not expose to rain and moisture.
- Don’t throw this product away just as general trash, please deal with the product follow the abandon electronic product regulation in your country.
MOUNTING AND RIGGING
Pay attention to safety! Please respectively consider the EN 60598-2-17 and the national standard during the installation. Only authorized technicians can carry out the installation.
Rigging
- The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming demolition. The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
- When rigging, de-rigging or servicing the fixture staying in the area below the installation place, on bridges, under high working places and other endangered areas is forbidden. The operator has to make sure that the safety measure and the machine’s technical installation is approved by an expert before taking into operation for the first time and after changes before taking into operation an-ther time. He has also to make sure that an expert approves safety measure and the machine’s technical installation once a years.
IMPORTANT: Overhead rigging requires extensive experience, including (but not limited to) calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury or property loss.
- If the fixture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The fixture must never be fixed swinging freely in the room.
CAUTION: Use appropriate clamps to rig the fixture on the truss. Make sure that the device is fixed properly! Ensure that the structure (truss) to which you are attaching the fixtures is secure.
Water / Moisture
- The product is for indoor use. In order to prevent risk of fire or electric shock, do not expose to rain or moisture
- The unit can not be used near water; for example near a bathtub, a kitchen sink, a swimming pool, etc.
Heat
- Do not use in a confined space. Always install the product in a location with adequate ventilation, at least 20in (50 cm) from adjacent surfaces. Be sure that no ventilation slots on the product’s housing are blocked.
- The apparatus should be located away from heat sources such as radiators, stoves or other appliances that produce heat.
- Don not use it when maximum ambient temperature is higher than 50°C. Work temperature ranges from -20°C to 50°C (-4°F to 122°F).
Servicing
- Do not implement any servicing other than those means described in the manual. Refer all servicing to qualified service personnel only. The internal components of the equipment must be purchased from the manufacturer. Only use accessories/attachments or parts recommended by the manufacturer.
INTRODUCTION
SCENIC C1012 is a compact and lightweight LED Par designed for live events,
club installations and all those indoor applications where colored lights with
narrow beam (25°) are required. The light source features 12x10W RGBW 4in1
LEDs, de-signed to create bright and intense colors. Its main strengths are
reliability and flexibility. The first is based on quality and selection of LED
chips, the quality of optical lenses and the use of digital processor
technology for LED chip temperature and fan speed control in order to preserve
LED life and color brilliance. The second point, flexibility, means that users
can choose to turn off the fan by renouncing part of luminance and make the
fixture totally silent. This could be very useful to rental companies and
professionals in all those “on the fly” situations, where total silence is
needed (houses of worship, theaters, confer-ence halls, etc.) and do not have
silent multicolor fixtures enough or simply because the installation requires
more fixtures than those available.
SCENIC C1012 is color at hand, without hassles in any venue.
Features
- High brightness / long lifespan LED chips with high-quality lens
- RGBW 4in1 color mixing
- Flicker-free LED emission for broadcast applications
- 6/9CH DMX-512 control with RDM
- 25° beam angle with an advanced dimmer system and strobe effects
- The intelligent fan speed and control with low-noise fan
- Lightweight aluminum housing with an all-directional ventilation system
Product Dimensions and Overview
Product Setup
Rear Panel Description
The operation panel includes the LED display and control button operation
area.
4 Digit LED Display
It shows the operating mode and other system information.
Control Buttons
- MENU Button – Short-press it to switch the setting pages.
- UP Button – It scrolls up individual items in the selection menu and sub-menus for system settings (DMX address, Operation Mode, etc.), and increases values/settings of parameters.
- DOWN Button – It scrolls down individual items in the selection menu and submenus for system settings (DMX address, Operation Mode, etc.), and increases values/settings of parameters.
- ENTER Button – Press ENTER to access menu levels and confirm parameter value changes.
Power Input/Output Sockets
Plug the power-cord included with SCENIC C1012 into an AC socket properly
configured for this fixture. Please read “5.2. About Power Connection” on page
10 for details. This fixture is also equipped with an output power connector
to be used as power mains source in case of cascade connection up to a maximum
of 5 fixtures.
DMX Input/Output Sockets
DMX Input is a 3-pin male XLR socket for connection to a DMX control device.
DMX output is a3-pin female socket for sending the DMX control signal to other
units.
About Power Connection
- Always make sure that the voltage of the outlet you are connecting the product to is within the range stated in paragraph “8 – Specification” on page 16 or rear panel of the product (AC110V-240V 50/60Hz).
- Make sure the power cord is not crimped or damaged. Never connect this product to a dimmer pack or rheostat.
- Never disconnect the product from power cord by pulling or tugging on the cord.
- To avoid electric shock, all fixtures must be connected to circuits with a suitable ground and circuit breaker.
- Wire correspondence is as follows:
Cable (EU)| Pin| International
---|---|---
Brown| Live| L
Blue| Neutral| N
Yellow/Green| Earth|- Earth must be connected! Always pay attention to safety! Before taking into operation for the first time, the installation has to be approved by an expert.
About Dmx Connection
When use a DMX controller, please make sure that there is no interference
sources (e.g. intercom, high frequency radio waves and radiation source). DMX
machines are designed to receive data through a serial Daisy Chain. A Daisy
Chain connection is where the DATA OUT of one fixture connects to the DATA IN
of the next fixture. The order in which the machines are connected is not
important and has no effect on how a controller communicates to each of them.
Use an order that provides for the easiest and most direct cabling
.
Connect machines using shielded 2-conductor twisted pair cable with 3-pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-), and pin 3 is Data positive (S+).
CAUTION: Wires must not come into contact with each other; otherwise the fixtures will not work at all, or will not work properly.
DMX Terminator
DMX is a resilient communication protocol, however errors still occasionally
occur. In order to prevent electrical noise from disturbing and corrupting the
DMX control signals, a good habit is to connect DMX output of last fixture in
the chain to a DMX terminator, especially over long signal cable runs. The DMX
terminator is simply an XLR connector with a 120Ω (ohm), 1/4 Watt resistor
connected across Signal (-) and Signal (+), respectively, pins 2 and 3, which
is then plugged into the output socket on last projector in the chain. The
connections are illustrated below.
- Complimentary signal cable can transmits signals to 20 unit fixtures at most. Signal amplifier is a must to connect more fixtures.
3-Pin vs 5-Pin DMX cables
DMX connection protocols used by controllers and fixtures manufacturers are
not standardized around the world. However, two are the most common standards:
5-Pin XLR and 3-Pin XLR system. If you wish to connect this fixture to a 5-Pin
XLR input fixture, you need to use an adapter-cable or make it by yourself.
Below you can see the wiring correspondence between 3-Pin and 5-Pin plug and
socket standards
Menu Operation
By pressing MENU button, the display will cycle through 12 different menus. Press ENTER button to enter the corresponding menu, press UP or DOWN to modify current parameter value. Then, press ENTER button again to save current value
No. | Menu | Function |
---|---|---|
1 | d— | DMX512 address code setting: 001-512. When there is an incoming DMX |
signal, the
lower right corner indicator lights up
2| r—| Red brightness adjustment: 0-255
3| G—| Green brightness adjustment: 0-255
4| b—| Blue brightness adjustment: 0-255
5| n—| White brightness adjustment: 0-255
6
|
F—
| Stroboscopic/speed adjustment: 0 = N/C
1-84 = lightning strobo 85-169 = random strobo
170-255 = standard stroboscopic
7
|
Pr–
(Internal Preset)
| PR01 red PR02 green PR03 blue PR04 white
PR05 red + green
PR06 red + blue
| PR07 green + blue
PR08 red + green + blue + white PR09 hopping
PR10 gradient PR11 strobe
PR12 combined effect
8| SP–| Built-in program speed setting: SP01-16
9| AU–| Auto/Audi: Auto/Sound control
10| FAN-
(*)
| FAN0: Fan works only when LED temperature is above 40°C FAN1: Silent mode
FAN2: Fan always working
11| dp–| dp0/1: 30s instant blackout and light on
12| CH–| CH9/CH6 Model selection
- Read “6.3. Fan Noise & LED Temperature Control” on page 14 for further details.
Set DMX Address
When selecting a starting DMX address, always consider the number of DMX
channels. If you choose a starting address that is too high, you could
restrict the access to some of the product’s channels. SCENIC C1012 uses 6 DMX
channels or 9 DMX channel (according to the DMX mode chosen), which defines
the highest configurable address to 505 or 496 to have all channels
controllable. Set the SCENIC C1012 starting address in the 001 – 505 DMX range
to enable control of up to 85 products in the 6-channel control mode. Set the
SCENIC C1012 starting address in the 001 – 496 DMX range to enable control of
up to 56 products in the 9-channel control mode. To choose between 6 or 9
channel operation, press MENU till you reach “CH–” page and press ENTER; you
then see current CH9 or CH6 current mode. Press UP or DOWN to select desired
value. Then press ENTER to confirm, and press MENU to return to menu main
page. To change DMX address, press MENU till you reach “d—” page and press
ENTER; you then see current DMX channel. Press UP or DOWN to select desired
value according to previous instructions. Then press ENTER to confirm, and
press MENU to return to menu main page.
DMX Channel Assignments and Values
When use DMX control , the system takes 6 or 9 channels (depending on selected
DMX mode. Below you can see the channel assignments for both modes.
9-ch DMX512 Channel Chart
| |
---|---|---
CHANNEL| FUNCTION| DESCRIPTION
Channel 1| Total Dimming| 0-255: Total dimming linear dimming , from Dark to
Bright.
Channel 2| Red| 0-255: Red linear dimming, from Dark to Bright.
Channel 3| Green| 0-255: Green linear dimming, from Dark to Bright.
Channel 4| Blue| 0-255: Blue linear dimming, from Dark to Bright.
Channel 5| White| 0-255: White linear dimming, from Dark to Bright.
Channel 6
|
Strobe
| 0: N/C
1-84: Conventional Strobo
85-169: Random Strobo
170-255: Lightning Strobo
Channel 7
|
Color Preset
| 0: N/C
1-30 Red
31-61 Green
62-92 Blue
93-123 White
| 124-154 Red+Green
155-185 Red+Blue 186-216 Green + Blue 217-255 Full Light
Channel 8
|
Static Mixing + Auto
| 0-20: N/C
21-38 Red
39-57 Green
58-76 Blue
77-95 White
96-114 Red+Green
115-133 Red+Blue
| 134-152 Green+Blue
153-171 Full Bright
172-190 Gradient
191-209 Jump
210-228 Strobe
229-255 Complete Effect
---|---|---|---
6-ch DMX512 Channel Chart
| |
---|---|---
CHANNEL| FUNCTION| DESCRIPTION
Channel 1| Total dimming| 0-255 : Total Linear Dimming , from Dark to Bright.
Channel 2| Red| 0-255 : Red Linear Dimming, from Dark to Bright.
Channel 3| green| 0-255 : Green Linear Dimming, from Dark to Bright.
Channel 4| blue| 0-255 : Blue Linear Dimming, from Dark to Bright.
Channel 5| white| 0-255 : White Linear Dimming, from Dark to Bright.
Channel 6| Strobe| 0: N/C
1-84: Conventional Strobo
| 85-169: Random Strobo
170-255: Lightning Strobo
Fan Noise & LED Temperature Control
SCENIC C1012 is equipped with a digital processor that controls fan speed
and LED temperature. Users can choose among 3 operative modes from FAN0 to
FAN2 as explained in “6 – Menu Operation” on page 12. Users can select the
desired mode by pressing MENU button until they reach the “FAN-” page. Press
ENTER; you see the current value. Then press UP or DOWN to choose from FAN0 to
FAN2. Press ENTER to confirm and MENU to go back to the selection of menu
pages. FAN0 keeps the fan off when LED temperature is below 40°C (104°F). It
comes intooperation form 41°C (105°F ca.), and the DSP increases fan speed
according to LED board temperature. Heat protection limit is fixed at 90°C; in
normal conditions, this limit is never exceeded, as fan would act to cool the
chip. Maximum noise @ 1m (max. fan speed) is 43dBA ca. FAN1 (Silent Mode)
always switches the fan off. Internal DSP controls the LED temperature and
adjusts its brightness to keep the chip always cooled. Brightness reduction
starts from 41°C (0% reduction) to 87°C (40% reduction ca.). Fan noise is
0dBA. FAN2 preset keeps the fan always working, so the LED board temperature
will always be kept cooled. Fan noise @ 1m is 43dBA ca.
Master/Slave Mode
In case you need to control more SCENIC C1012 simultaneously (all fixtures
operate exactly the same way) without the use of a DMX controller, you can use
the Master/ Slave function. There is no specific function to be activated on
the display; simply the master unit must be connected first, all the others in
daisy-chain through the DMX IN-OUT connections. All units (master and slaves)
should be in DMX Channel 001 only, and have same Channel Mode (all 6CH or
9CH).
Troubleshooting
Problem | Probable Cause(s) | Remedy |
---|
No response from fixture
when power is applies
| No power to fixture| Check power cables
Check mains plug
Fixture does not reset
correctly
| Electronic failure| Contact service technician*
No light, LED cuts out intermittently, or burns out too quickly
| LED missing or blown| Disconnect fixture and replace
the LED
Fixture or LED is too hot
| Allow fixture to cool. If prob- lem persists, contact service
technician*
Fixture resets but does not respond correctly to controller (DMX mode operation)
| Controller not connected| Connect controller
Incorrect addressing of the
fixtures
| Check address setting on fixture
and controller
Bad data link connection
| Inspect cables and correct poor connections and/or broken
cables.
Conflict between tracking
and vector control
| Eliminate scene cross-fade on
controller
Data link not terminated| Insert termination plug in output
of last fixture**
Defective fixture on 2 devices transmitting on link
| Bypass fixtures one at a time until normal operation is regained: unplug both connec- tors and connect them directly
together
- To contact CentoLight service, see “9 – Warranty And Service” on page 17 or visit www.centolight.com
- For instruction on how to install a DMX terminator, see “5.4. DMX Terminator” on page 11.
Specification
Light Source | 12 x 10W LED |
---|---|
Color System | RGBW 4in1 |
LED Control | Flicker-free |
Optical System | 25° lens |
Light Source Life-Cycle | > 50.000 h |
Dimmer | 0-100% linear dimming with Sinusoidal Smooth Subdivision |
Technology
DMX Control Mode| DMX512 6CH/9CH with RDM
Operating Modes| Master/Slave, Sound Active, Manual
Strobe| 0-30Hz
Cooling System
| All-Direction Ventilating System with DSP control (fan is stopped when LED board temperature is under 40°C; it runs
when it is over)
Fan Noise| 0dB (temp under 40°C); 43.0 dBA @ 0.5m (temp. above 41°C);
46.1 dBA close to fixture
IP Rate| IP20
Working Temperature| Room Temperature between -20°C and 50°C (-4°F to 122°F)
Housing| Aluminum with fine sand wear-resistant spray paint
Operating Voltage| 110V-240V / 50-60Hz
Power Consumption| 140W max.
Fixture Size (LxD)| Min. Ø228 x 138.5 mm (Ø8.98 x 5.45 in); Max. – bracket
includ-
ed – Ø282 x 253 mm (Ø11.10 x 9.96 in)
Fixture Weight| 2,7 kg (5.95 lbs.)
Carton Size (LxHxD)| 290 x 290 x 290 mm (11.42 x 11.42 x 11.42 in)
Carton Weight| 3,75 kg (8.27 lbs.)
Note: Our products are subject to a process of continual further development. Therefore modifications to the technical features remain subject to change without further notice.
Warranty And Service
All CENTOLIGHT products feature a limited two-year warranty. This two-year warranty starts from the date of purchase, as shown on your purchase receipt. The following cases/components are not covered by this warranty:
- Any accessories supplied with the product
- Improper use
- Fault due to wear and tear
- Any modification of the product effected by the user or a third party
CENTOLIGHT shall satisfy the warranty obligations by remedying any material or manufacturing faults free of charge at CENTOLIGHT’s discretion either by repairing or exchanging individual parts or the entire appliance. Any defective parts removed from a product during the course of a warranty claim shall become the property of CENTOLIGHT.While under warranty, defective products may be returned to your local CENTOLIGHT dealer together with the original proof of purchase. To avoid any damages in transit, please use the original packaging if available. Alternatively, you can send the product to CENTOLIGHT SERVICE CENTER – Via Enzo Ferrari, 10 – 62017 Porto Recanati – Italy. In order to send a product to service center, you need an RMA number. Shipping charges have to be covered by the owner of the product. For further information please visit www.centolight.com
Warning
PLEASE READ CAREFULLY – EU and EEA (Norway, Iceland and Liechtenstein) only This symbol indicates that this product is not to be disposed of with your household waste, according to the WEEE Directive (2012/19/UE) and your national law. This product should be handed over to a designated collection point, e.g., on an authorized one-for-one basis when you buy a new similar product or to an authorized collection site for recycling waste electrical and electronic equipment (WEEE). Improper handling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, waste authority, approved WEEE scheme or your household waste disposal service.