VOLTCRAFT DLP-3303 Laboratory Power Supply Instruction Manual

June 9, 2024
VOLTCRAFT

Safety Instructions
DLP-3303 Laboratory power supply
Item no: 2619139
Instruction Manual

Intended use

The power supply is used as a potential-free DC mains supply to operate low- voltage devices. It is connected via 4 mm safety sockets. The output voltage and current can be adjusted. The DC output is electrically isolated and features protective isolation towards the mains voltage.
The device should be connected to and operated with an earthed socket of the public mains supply only. The socket should be within easy reach of the user, or the device should be operated via an all-pole cut-off device (central cut- off).
The product is designed for private and commercial use.
In commercial institutions, the accident prevention regulations of the Employer’s Liability Insurance Association for Electrical Systems and Operating Materials are to be observed.
The product can be used in schools and training centres. The use must be supervised by trained personnel.
The product is intended for indoor use only. Do not use it outdoors.
Contact with moisture must be avoided under all circumstances.
If you use the product for purposes other than those described, the product may be damaged.
Improper use can result in short circuits, fires, electric shocks or other hazards.
The product complies with the statutory national and European requirements.
For safety and approval purposes, you must not rebuild and/or modify the product.
Read the safety instructions and any accompanying instructions carefully and store them in a safe place. Make this product available to third parties only together with the safety instructions and any accompanying instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.

Latest product information

Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

Description of symbols

The following symbols are on the product/appliance or are used in the text:

| The symbol warns of hazards that can lead to personal injury.
---|---
| The symbol warns of dangerous voltage that can lead to personal injury by electric shock.
| Fuse location
| Protective conductor connection. Do not detach.
| Safety transformer

Safety instructions

Read this document and the accompanying operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.

4.1 General

  • The product is not a toy. Keep it out of the reach of children and pets.
  • Do not leave packaging material lying around carelessly. This may become dangerous playing material for children.
  • If you have questions which remain unanswered by this information product, contact our technical support service or other technical personnel.
  • Maintenance, modifications and repairs must only be completed by a technician or an authorised repair centre.

4.2 Handling

  • Handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.

4.3 Operating environment

  • In commercial institutions, the accident prevention regulations of the employer’s liability insurance association for electrical systems and operating facilities are to be observed.

  • Do not place the product under any mechanical stress.

  • Protect the appliance from extreme temperatures, strong jolts, flammable gases, steam and solvents.

  • Protect the product from high humidity and moisture.

  • Protect the product from direct sunlight.

  • Do not switch the product on after it has been taken from a cold to a warm environment.
    The condensation that forms might destroy the product. Allow the product to reach room temperature before you use it.

  • Do not operate the product in explosive atmospheres, such as in the presence of flammable liquids, gases or dust.

4.4 Operation

  • Only connect the product to a normal mains socket connected to the public supply. Before plugging in, check whether the voltage stated on the rating plate complies with the voltage of your electricity supplier.
  • Consult an expert when in doubt about the operation, safety or connection of the product.
  • Do not use the device shortly before or after a thunderstorm (lightning/high-power surges). Make sure that your hands, shoes, clothing, the floor, the measuring device/test leads, circuits and circuit components are dry.
  • Take particular care when dealing with voltages exceeding 25 V/AC or 35 V/DC. Touching electrical conductors with these voltages may cause a fatal electric shock.
  • The product will heat up during operation; ensure appropriate ventilation. Do not cover the ventilation openings on the device!
  • Do not leave the product and connected consumers in operation unattended.
  • Do not disassemble the product! An electric shock can be life-threatening! Capacitors in- side the device may still be charged, even if the device has been disconnected from all voltage sources.
  • The product is not designed for use on humans or animals.
  • Only use fuses of the specified type and rated current. Repaired fuses must not be used.
  • Do not use bare wires for connections. There is a risk of short-circuit and fire.
  • Use test leads that meets the voltage and current specifications of this device. There is a risk of fire due to overvoltage.
  • If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. DO NOT attempt to repair the product yourself. Safe operation can no longer be guaranteed if the product:
    – is visibly damaged,
    – is no longer working properly,
    – has been stored for extended periods in poor ambient conditions or
    – has been subjected to any serious transport-related stresses.

4.5 Mains cable
Do not modify or repair mains supply components including mains plugs, mains cables, and power supplies. Do not use damaged components. Risk of death by electric shock!

  • The mains outlet must be located near to the device and be easily accessible.

  • Never plug in or unplug the mains plug when your hands are wet.

  • Never pull the mains plug from the socket by pulling at the cable. Always pull it from the mains socket using the intended grips.

  • Unplug the mains plug from the mains socket if you do not use the device for an extended period of time.

  • Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety.

  • Make sure that the mains cable is not squeezed, bent, damaged by sharp edges or put under mechanical stress.

  • Avoid excessive thermal stress on the mains cable from extreme heat or cold.

  • Do not modify the mains cable. Otherwise the mains cable may be damaged. A damaged mains cable can cause a deadly electric shock.

  • Do not touch the mains cable if it is damaged.
    – First, power down the respective mains socket (e.g. via the respective circuit breaker) and then carefully pull the mains plug from the mains socket.
    – Never use the product if the mains cable is damaged.

  • A damaged mains cable may only be replaced by the manufacturer, a workshop com- missioned by the manufacturer or a similarly qualified person, so as to prevent any danger.

  • Ensure that cables are not pinched, kinked or damaged by sharp edges.

  • Always lay cables so that nobody can trip over or become entangled in them. This poses a risk of injury.

4.6 Connected devices

  • Also observe the safety and operating instructions of any other devices which are connected to the product.

Cleaning

Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.

  1. Disconnect the product from the power supply.
  2. Let the product cool down to ambient temperature.
  3. Clean the product with a dry, fibre-free cloth.

Disposal

This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free takeback of waste. Conrad provides the following return options free of charge (more details on our website):

  • in our Conrad offices
  • at the Conrad collection points
  • at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG End users are responsible for deleting personal data from the WEEE to be disposed of.
    It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.

Technical data

Input voltage ……………………………. 220 – 240 V/AC
Input AC frequency …………………… 50/60 Hz
Fuse………………………………………… 250V, 3A
Output voltage …………………………. 0 – 30 V/DC
Output current ………………………….. 0 – 3 A
Output power …………………………… 198 W
Operating temperature ……………… 0 to +40 °C
Operating humidity …………………… ≤ 90 % RH (non-condensing)
Storage temperature …………………. -20 to +60 °C
Storage humidity ………………………. ≤ 90 % RH (non-condensing)
Weight (approx.) ………………………. 9.8 kg

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2619139_V2_0223_jh_ss_en 18014399227323403-2 I3/O2 en

www.conrad.com/downloads

Documents / Resources

| VOLTCRAFT DLP-3303 Laboratory Power Supply [pdf] Instruction Manual
DLP-3303 Laboratory Power Supply, DLP-3303, Laboratory Power Supply, Power Supply, Supply
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals