SDT Ultra Checker Ultrasound Detection Kit User Manual
- June 9, 2024
- SDT
Table of Contents
SDT Ultra Checker Ultrasound Detection Kit
Instruction
Powering your equipment:
Open up the battery compartment using the supplied screwdriver. Correctly
insert two AA alkaline or rechargeable batteries. The remaining battery level
is displayed in the right-hand top corner 1 .
A full green battery in the right-hand top corner means that the battery is
fully charged. The equipment’s autonomy when fully charged will be around 7
hours.
The device can be powered through its USB port 2 with an external battery
pack.
Important: The ULTRA Checker turns off automatically when the battery power is insufficient to ensure proper operation, or after 10 minutes of inactivity.
Connecting the sensor cable :
Connect the cable of the sensor to the device by lining up the red dot on the
plug with the red mark on the connector 9 and then inserting the plug into the
connector.
To unplug them, move-up the knurled barrel of the plug without any rotating
movement.
Proceed in the same way to connect and unplug the cable on the side of the
flexible extension. The ‘Sensor ?’ messages 10 indicate that no or an
incompatible sensor is connected.
The “x”- “sensor” indication will only disappear when the ULTRA Checker is
correctly wired up and connected to the correct sensor.
Using the ULTRA Checker:
When pressing the on/off switch 4, the equipment will switch on immediately.
To switch off, the on/off button needs to be pressed for approx. 2 seconds.
To take a correct measurement, the amplification needs to be adjusted for
every reading. This is done by using the up and down arrows 5 and following
the triangular amplification guidance icons 5 in the top left hand corner of
the display.
The current amplification setting is displayed here7 .
Once the correct amplification level is reached, the reading (measurement)
will be displayed in green and a “smiley” J will appear in the place where
previously the triangular amplification guidance icon was shown. When the
reading (measurement) is displayed in red, the amplification is too high and
will need to be reduced by pressing the “arrow down” button. When ‘’-.-‘’ is
displayed on the screen, the amplification is too low and will require
increasing by pressing the “arrow up” button. In both cases, i.e. when the
amplification is too low or too high, the amplification should be adjusted
until the reading(measurement) is displayed in green and the smiley appears in
the left hand top corner.
Using the headphones:
To enhance the hearing experience, the audio volume of the headset can be
adjusted by pressing the left and right arrows 5 until the sound level is
comfortable.
Avoid setting the sound too low as otherwise some signals may not be heard and
possible leaky spots overlooked. Connect the headphones here 3. Set the volume
to a safe level to protect yourself from permanent hearing loss. The current
volume setting is displayed 8 only when a headset is connected.
Specifications
General| Mechanical|
---|---|---
Function| Ultrasound measurement device| Housing material| ABS|
Operable with
| SDT FlexID2, SDT LUBESense1, SDT RS2
Threaded/Needle, SDT AIRSense, SDT ULTRASense, SDT PARADish2 (since v3.1.535)|
Dimensions housing| 158x59x38.5 mm 6.22”x2.32”x1.51”|
Weight| 164g | 5.78oz|
Measurement
interface
| 1 channel via a 7 pole LEMO connector|
Power|
Display| 160×128 pixels Color OLED| Battery| 2 AA batteries|
Keyboard| 5 function keys| Autonomy| 7 hours|
Measuring range| -6 to 99.9 dBµV (ref 0 dB = 1 µV)|
Audio|
Resolution| 0.1 digits|
Operable with| Provided Headphones|
Environmental|
Attenuation| 25 dB NRR|
Operating tempera- ture range| -10 to +50 °C |14 to 122°F non- condensing|
Headset| 25dB NRR Peltor HQ headset|
IP rating| IP42|