TESLA TSL-SEN-SMOKE Smart Sensor Smoke User Manual
- June 4, 2024
- Tesla
Table of Contents
- TESLA TSL-SEN-SMOKE Smart Sensor Smoke
- Packing List
- Product Description
- Indicator and Buzzer States
- Network Setting
- Installation Instructions
- Precautions
- Fire Alarm Function
- Alarm and Test
- Mute Function
- Routine Maintenance
- Troubleshooting
- Technical Parameters
- INFORMATION ABOUT DISPOSAL AND RECYCLING
- EU DECLARATION OF CONFORMITY
- Manufacturer
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESLA TSL-SEN-SMOKE Smart Sensor Smoke
Packing List
Please check if all accessories are included
Product Description
Please check if all accessories are included
Indicator and Buzzer States
Red indicator flashes. The buzzer beeps. The alarm is triggered. The red indicator flashes once every 50 seconds. The buzzer does not beep. The product works properly. The yellow indicator flashes once every 40 seconds. The buzzer beeps shortly. Battery power is low. Red indicator flashes. The buzzer beeps 4 times. The product is in a self-checking and alarm-simulating state. The Green indicator flashes quickly. The buzzer does not beep. The product is in network setting mode.
Network Setting
- Power on the product
- Rotate the mounting base anticlockwise to open.
- Remove the battery insulation film.
- Press the reset button for 5S and release, the green LED will flash for the network setting.
Network setting note
- Press the button for 5s-10s, the red LED is on, it will turn off after 5s. Then the green LED is on. Release the reset button, the green LED flashes for the network setting.
- The green LED will be on for 5s then turns off to indicate the network setting succeeds, the product is in networking detecting status. If the network setting fails in the 60s, the yellow LED is on for 5s then turns off, and the product is in standalone working status.
Installation Instructions
Installation methods
Using screws
- Use screws to fix the mounting base to the ceiling.
- Rotate the product clockwise into the mounting base.
Using a 3M sticker
- Remove the protective film from the 3M sticker and attach the sticker to the mounting base.
- Remove the protective film from the 3M sticker and attach the product to the ceiling.
Installation checking
Check if the product is installed properly.
- If the semicircle on the product is aligned with the line on the mounting base to form an arrow, the product is installed improperly.
- If the semicircles on the product and mounting base are aligned to form a circle, the product is installed properly.
Precautions
- Mount the product only on indoor ceilings.
- Install the product at least 50 cm away from lighting products.
- Do not install the product in bathrooms or other moist environments.
- Do not install the product in places with non-fire smoke or steam.
- Ensure that the temperature of the installation environment is within the range of-10°C to +55°C.
- If a cupboard is near the ceiling, install the product at least 60 cm away from the cupboard.
- Install the product at least 150 cm away from ventilators, air conditioners, and air vents.
- You are advised to use screws to install the product. If you use a 3M sticker to install it, any product damage] or safety accidents incurred therefrom will be your responsibility.
- If you choose to use a 3M sticker, affix the product to a smooth, even, dry, and clean surface.
- Regularly check whether the product is attached to the surface securely to prevent it from falling down.
- The product cannot be mounted to the mounting base unless the battery is installed.
- If you affix the product to a painted surface, peeling of the paint may cause the product to fall down. If this occurs, you are liable for any problems incurred therefrom.
Fire Alarm Function
- When the product detects smoke, it immediately sends audible and visual alarm signals.
- In case of fire, take proper measures immediately. For example, call the fire emergency number, or use a fire extinguisher to put out the fire.
- If there is no fire, press the mute/self-diagnostic button to mute the product. The product will be mute for 90s. During this period, the product will not generate any audible or visual alarm. After 90s, the product will be restored to the detection state.
The product will generate a fire alarm when the following items contact it directly:
- Mist sprayed from pesticides or cosmetics
- Smoke generated by cigarettes and incense sticks
- Smoke-type or thermal evaporation-type pesticides
- Cooking smoke or steam
- Condensation
Alarm and Test
-
Detection state: The status indicator blinks red at 50s intervals.
-
Self-checking state: When you press the mute/self-checking button, the status indicator will turn red. If you press and hold the mute/ self- diagnostic button for less than 5s, the product will enter the self-checking state, the status indicator will flash red, and the buzzer will beep (same as in the alarm state).
-
When the smoke density reaches the preset alarm threshold, the product generates an alarm.
-
During the self-checking test, keep away from the buzzer to avoid loud alarm sounds from damaging your hearing.
-
If the product generates an alarm when it is monitored, potential risks may exist. Do not ignore the alarm and try to locate the cause.
IMPORTANT: Ignoring the alarm could result in property damage, personal injury, or even death. If the product fails a test, see „Troubleshooting“ to rectify the fault. If the fault persists, replace the product immediately.
Mute Function
If the product generates an alarm, potential risks may exist. Before you mute, the product, ensure that there is no fire. Do not block the product or disable it in any way. If you do so, the product can no longer provide you with protection. If the product generates an alarm because it detects smoke in the kitchen but not a fire (for example, bacon frying), press the mute/self- diagnostic button on the panel to mute the product. When the product is muted, the status indicator will rapidly blink red. The product sensitivity will be restored automatically within the 90s.
Note: If the smoke density surrounding the product is still high, the product will generate an alarm again. Open the door and window to let out the smoke.
If you do not know the cause of the alarm, try to locate the source of the smoke, as ignoring the alarm could result in property damage, personal injury, or even death.
Routine Maintenance
The product has a maintenance-free design. You only need to perform the following routine operations to ensure that the product works properly.
- Suggest testing the product at least once every week. For details on how to test the product, see „Alarm and Test“.
- Keep the product clean and remove dust from it with a vacuum cleaner and soft brush at least once every year.
Use a cotton cloth or sponge to clean the product. Do not use solvents or detergents, which may enter the product and cause damage to the sensor or circuit.
Note: Do not paint your product. The paint may block the smoke the intake vents of the product, causing the product to malfunction.
Troubleshooting
If the product malfunctions, its battery may have reached its] valid lifespan, or the product may be affected by dust, smoke residue, or other dirt. If this is the case, refer to „Routine Maintenance“ for instructions on cleaning the product. If the fault persists, perform the following operations:
- If the product does not respond, check whether the product is correctly mounted to the mounting base.
- If the product intermittently beeps (at about 40s intervals), the battery level is low. Replace the battery within one week.
- If you often encounter a non-fire alarm, please try to relocate your smoke alarm.
- If the product generates alarms frequently when there is no fire or smoke, clean the product or reinstall the product in another position.
IMPORTANT: If the fault persists after you perform the preceding operations, contact the local vendor. Do not disassemble the product yourself, or the warranty service for the product will become invalid.
Technical Parameters
Wireless Technology | ZigBee |
---|---|
Transmission Frequency | 2.4 GHz |
Working Voltage | DC 3 V CR123A battery |
Low power indication | Supported |
Working Temperature | -10°C to +55°C |
Detector Type | Independent smoke detector |
Alarm Sound Pressure | ≥ 80 dB (3 m in front of the smoke detector) |
Installation Position | Ceiling |
Battery Lifespan | More than 3 years (20 times/day) |
Dimensions | 90 mm x 37 mm |
INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for separate collection. The product must be disposed of in accordance] with the regulations for disposal of electrical and electronic] equipment (Directive 2012/19/EU on waste electrical] and electronic equipment). Disposal together with regular municipal waste is prohibited. Dispose of all electrical and electronic products in accordance with all local and European regulations at the designated collection points which hold the appropriate authorisation and certification in line with the local and legislative regulations. Correct disposal and recycling help to minimise impacts on the environment and human health. Further information regarding disposal can be obtained from the vendor, authorised service centre or local authorities.
EU DECLARATION OF CONFORMITY
Hereby, Witty, s.r.o declares that the radio equipment type TSL-SEN-SMOKE is in compliance with EU directives. The full text of the EU declaration of conformity is available at the following internet address: teslasmart.com/declaration
- Connectivity: Wi-Fi 2,4 GHz IEEE 802.11b/g/n
- Frequency band: 2.412 – 2.472 MHz
- Max. radio-frequency power (EIRP): < 20 dBm
Manufacturer
Tesla Global Limited
- Gee Chang Industrial Building,
- 121 Des Voeux Road Central
- 852 00 Hong Kong
- www.teslasmart.com
References
Read User Manual Online (PDF format)