Welcome to the world of KENT, leader of water purification industry in India. With a KENT product you have all the reasons to smile, since at KENT, we take pride in the quality and laboratory-tested performance of our products.
We are confident that your decision to own KENT Gold Star UF Membrane Storage Water Purifier will go a long way in serving you with safe and clean drinking water – thus keeping you and your family in good health. We assure you that you will be satisfied with its performance and quality, which comes without any compromise.
This manual is an effort towards familiarizing you with the operation and maintenance of KENT Gold Star. Before operating the unit, please read it thoroughly and retain it for future reference. Should you need further assistance or information, do not hesitate to contact your nearest KENT dealer or branch.
Best Wishes,
KENT RO SYSTEMS LTD.

Introduction
Presenting the all new KENT Gold Star UF Membrane Storage Water Purifier, which gives you truly purer water and protects your family against waterborne diseases. With innovative KENT Gold Star, dependence on electricity and usage of chemicalsto obtain purer drinkingwater are now problems of thepast.
At the heart of KENT Gold Star is a state-of-the-art Hollow Fiber UF (Ultra Filtration) Membrane. The pores of this UF Membrane are so fine that they do not allow any Bacteria (Tested by Toray, Japan) to pass through. This makes drinking water purer without use of any chemicals like Chlorine, Bromine or Iodine.

Items in the box

Please verify the following items in the packaged box:

  1. Bottom Tank 1 No.
  2. Top Tank with Fitting 1 No.
  3. Middle Partition 1 No.
  4. Top Cover 1 No.
  5. Top Lid 1 No.
  6. Carbon Assembly with Inlet Funnel 1 Set
  7. Hollow Fiber UF Membrane Cartridge 1 No.
  8. Spare Sediment Filter 1 Set
  9. 50ml Cleaning Syringe 1 No.
  10. Y-Fork 1 No.
  11. Tap 1 No.
  12. Center Drill Sticker 1 No.
  13. Screws & Plastic Inserts 2 Nos. each
  14. Instruction Manual 1 No.

Salient Features

  • Ideal for Tap water or Municipal Corporation water supply.
  • Use of Hollow Fiber UF Membrane reduces Bacteria (Tested by Toray, Japan).
  • No use of chemicals such as Chlorine, Bromine or Iodine for purification. Thereby, providing healthy & tasty drinking water.
  • Use of Activated Carbon Filter for better disinfection of water.
  • Designed for wall mounting also so no binding to place it on the table/slab.
  • Very high storage capacity of 22 litres (14 litres in the Bottom Tank and 8 litres in the Top Tank), which makes purified water available on demand.
  • Food grade plastic construction for trouble free maintenance and long life.

Technical Specifications

table 1

WQA Performance Data:
This system has been tested according to NSF/ANSl-42 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limitforwater leaving the system, as specified in NSF/ ANSl-42.

“Gold filters are certified by WQA to NSF/ANSl-42 for the reduction of chlorine, foul taste and odour, as verified and substantiated by test data.” (Though testing was performed under standard laboratory conditions, actual performance may vary.)

Know your KENT Gold Star

image 1

Exploded view of KENT Gold Star

image 2

NOTE: ITEM NO. 3, 5 & 11 COMES IN A KIT (20062)

Important Instructions

  1. Avoid exposure to direct sunlight as overheating can damage the purifier’s plastic body.
  2. Do not confine the purifier in a cabinet.
  3. Keep both the storage tanks clean. They should be washed and properly rinsed with pure water once in a week.
  4. The Sediment and Carbon filters should be cleaned at least once in a month. or earlier, as per the quality of tap water (May be weekly, if the water is dirty).
  5. The U F Membrane should be back-washed at least once in a month or earlier, as per the quality of tap water (May be weekly, if the water is dirty).
  6. Replace Sediment Filter after every 3 months of use.
  7. Replace Carbon Filter after every 6 months of use.
  8. Replace UF membrane after every 12 months of use.
  9. Do not fill the water in the Top Tank if the water level in the Bottom Tank is above the maximum permissible level mark, otherwise it will result in overflow.
  10. On the date of installation, note down the date of next change for Filters and Membrane (as advised in nos. 6, 7 & 8 above) on the sticker placed on the right side of the purifier. This will help you in remembering the dates of change for the respective parts.
  11. The system should be used only with cold water.
  12. Do not use water that is microbiological unsafe or of unknown quality without adequate disinfection before or after the system.
  13. The system and installation must comply with applicable state and local laws & regulation.
FiItration Process

Tap Water or Municipal Corporation Water is filled in the Top Tank, which has a capacity of 8 litres. Water on being filled up passes through the Sediment Filter which reduces the suspended impurities. It then passes through activated carbon granules, which reduces organic/chemical impurities such as chlorine, bad taste and odour.
The filtered water gets collected in the Top Tank, and then percolates down through the UF membrane into the Bottom Tank. During this process, most of the bacteria (Tested by Toray, Japan) are reduced and only clean & safe drinking water is allowed to pass through. This purified water collects in the Bottom Tank, ready to be dispensed when required.

Setting up your KENT Gold Star

Open the box and remove the parts. Tally the contents with the ‘Items in the Box’ list (page no. 1 ). Wash all the plastic parts with clean water and wipe dry with a clean cloth before assembling. image 3

  • Once assembled, fill the top tank with water. Wait till the filtration is complete.
  • Drain the water collected in the Bottom Tank, initially for the first time, this water should be drained (Even if all parts are washed thoroughly before installation).
  • Once the Top Tank is empty, fill it again but only after checking the level of water in the Bottom Tank.
  • If the water level in the Bottom Tank is above the maximum permitted level, please do not fill the Top Tank (However, you can completely fill the Top Tank if the level of water in the Bottom Tank is below the maximum level mark).
  • To refill the purifier, rotate the Top Lid and remove it. Pour the raw water slowly into the Inlet funnel, ensuring that water does not spill.
  • After filling the Top Tank, close the Top Lid.

Installation Instructions for Wall Mounting

KENT Gold Star UF Membrane Storage Water Purifier is designed to facilitate both wall mounting as well as counter-top usage.
The purifier is easy and convenient to install. Recommended Site Preparations:

  • For installation of wall mounted purifier please refer to wall hanging diagram on page no. 8.
  • Installation space as per dimensions of the purifier.
  • For wall mounting installation, makesurethatpurifieris mounted on a wall.
  • Forcounter top, place the purifier at the edge the counter.
Installation Procedure:
  1. Paste the Centre drill sticker on wall at (3.6 Feet to 4.0 Feet from the ground) as per your convenience.

  2. Ensure that sticker should be pasted horizontal to the ground on wall. Then drill holes as per the space provided on the sticker.

  3. Now, insert the puff up with (as provided in kit) the help of hammer in the wall.

  4. Screw in two 1 0x50 self taping screws, (as provided in kit) 5.5 inches (140 mm) apart horizontally (in case of wall mounting).

  5. Wall-mount the purifier with the help of slot holes given on back side.
    Note:

    • If the wall is not vertical to the ground or the screws are not properly drilled in parallel position, it may damage the purifier.
    • Keep the device away from heat or direct sunlight.image 4

Maintaining your KENT Gold Star

Part 1: Cleaning the UF Membraneimage 5

Frequency

  • The UF Membrane should be cleaned at least once a month. However, if the water flow from Toptank to the bottom Tank reduces markedly during this period, the Membrane can be cleaned even earlier.
  • It is important to change the UF Membrane once a year.
  • For kindly address all the contact given on replacement the authorised back of element dealers the of such booklet. as KENT RO Sediment Systems Filter, Ltd. Carbon Or Filter, Customer UF Care as Membrane per the etc.,

Part 2: Cleaning the Water Tanksimage 6

Frequency: Both the Water Tanks should be cleaned once in a week.

Part 3: Cleaning the Sediment & Carbon Filtersimage
7

Frequency: Both Sediment & Carbon Filters should be cleaned once in a month.

Part 4: Replacing the Sediment Filterimage 8

Frequency: The Sediment Filter should be changed after every 3 months.

Part 5: Replacing the Carbon Filterimage 9

Frequency: The Carbon Filter should be changed after every 6 months.

Part 6: Replacing the UF Membraneimage 10

Frequency: UF Membrane should be changed every year.

Part 7: Restoring your KENT Gold Star (when leaving for long vacations)image 11

Frequency: Purifier should be restored, when going on a vacation for more than 7 days.