Altronix eBridge100ST EoC Hardened Mini-Transceiver Installation Guide
- June 3, 2024
- Altronix
Table of Contents
Altronix eBridge100ST EoC Hardened Mini-Transceiver Installation Guide
Overview
Altronix eBridge100ST EoC hardened transceiver transmits data at 100Mbps, Full Duplex over Coax cable to a paired eBridge receiver and provides power in a PoE/PoE+ compliant format to an enabled device/camera. The eBridge receiver is available in various options and is powered by an external midspan or endspan. The receiver passes PoE/PoE+ power over the same coax cable to the eBridge100ST transceiver, which, in turn, passes this power to an enabled IP camera/device. These plug and play units facilitate a cost-effective, simple way to replace legacy analog products with new IP devices over existing coax up to 300m.
Features
Agency Listings:
- UL/cUL Listed for Information Technology Equipment (UL 60950-1).
- CE European Conformity.
Compatible Receivers:
- eBridge100RM, eBridge400PCRM, eBridge800PCRM, and eBridge1600PCRM.
- eBridge800E Visit www.altronix.com for the latest compatibility list.
Input:
- Operating power provided by PSE (power sourcing equipment).
- Current draw: 1.5W
- PoE compliant to IEEE 802.3af (15W) and PoE+ compliant to IEEE 802.3at (30W) from eBridge receivers.*
Coax link:
- Throughput is rated to pass 100Mbps of data at distances up to 300m. (Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 4) for power delivery.
- Connectivity: BNC, RG-59/U or similar.
Ethernet:
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair CAT5.
- Distance: up to 100m.
- Speed: 10/100BaseT, half/full duplex, auto negotiation.
LED Indicators:
- Green – PoE ON (by respective RJ45 jack).
- Yellow and Green LED (RJ45) IP Link status, 10/100Base-T/active.
- Blue: Coax Link is active.
Environmental:
-
Operating Temperature:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W: – 40ºC to 60ºC (– 40ºF to 140ºF). -
Storage Temperature:
– 40ºC to 75ºC (– 40ºF to 167ºF). -
Humidity: 20 to 85%, non-condensing.
Functions:
- Auto detection and protection of legacy non-PoE cameras/devices.
Applications:
- Retrofit digital IP cameras in an analog CCTV installation.
- Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 2).
- Extend Network link distance in an industrial environment over 610m .
- Upgrade deployed CCTV Coax to a digital network in Retail, Casinos, Airports, Schools, Hospitals, etc.
Mechanical:
- Dimensions (W x L x H approx.): 2.27” x 2.645” x 1.12” (57.7mm x 67.2mm x 28.4mm).
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. eBridge100ST is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. eBridge100ST is intended for indoor use only.
- Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole (Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.
- Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2 and 3, pg. 3).
- Connect Coax from eBridge receiver (eBridge100RM, eBridge400PCRM, eBridge800PCRM, eBridge1600PCRM or eBridge800E) cable to BNC tether cable marked [Coax] (Fig. 2 and 3, pg. 3).
Note: This unit is designed to accommodate Megapixel, HD720, HD1080, and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card, to present a quality image. If the headend processing equipment’s speed is insufficient, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Technical Specifications
Parameter | Description |
---|---|
Connections | BNC for Coax link, RJ45 for camera/device. |
Input power requirements | PoE compliant to IEEE 802.3af (15W) and PoE+ |
compliant to IEEE 802.3at (30W) from eBridge100RM, eBridge400/800/1600PCRM or
eBridge800E.
Indicators| Yellow (RJ45 connector): On – Link, Off – No Link, Blinking –
Activity.
Green (RJ45 connector): On – 100Base-TX, Off – 10Base-T.
Green: PoE Active.
Blue: Coax Link is active.
Environmental Conditions| Operating Ambient Temperature (UL60950-1):
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF). For 30W: – 40ºC to 60ºC (– 40ºF to
140ºF).
Storage Temperature: – 40ºC to 75ºC (– 40ºF to 167ºF).
Relative humidity: 85% +/– 5%
Operating Altitude: – 304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology Equipment (UL
60950-1). CE European Conformity.
Weights (approx.)| Product: 0.22 lbs (0.1 kg) | Shipping: 0.4 lb. (0.18 kg)
Single PoE Camera Connection
*Note: Caution: once PoE connection is established between eBridge100RM and eBridge100ST, disconnection from eBridge100ST will not disable the PoE output voltage on the eBridge100RM. Although the eBridge100ST can be reconnected, caution should be taken not to connect coax wiring from eBridge100RM to any non-PoE device.
Typical Application
Maximum Length of Coax Type vs. Camera Power/PoE Class
Camera Power/PoE Class| RG59/U – 23AWG| RG59/U – 22AWG|
RG59/U – 20AWG| RG59/U – 18AWG| RG6/U – 18AWG
---|---|---|---|---|---
Max. Length (meters)
13W/0| 261| 336| 500| 500| 500
4W/1| 500| 500| 500| 500| 500
6.5W/2| 500| 500| 500| 500| 500
13W/3| 261| 336| 500| 500| 500
19W| 153| 198| 316| 500| 500
25W| 119| 151| 240| 366| 366
Support
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA |
718-567-8181 | fax:
718-567-9056
website: www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty
IIeBridge100ST Rev. 111714
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>