scancool SD 1500 Series Esta Drinks Fridge User Manual
- June 9, 2024
- SCANCOOL
Table of Contents
- scancool SD 1500 Series Esta Drinks Fridge
- SAFETY PRECAUTIONS
- PRECAUTIONS FOR INSTALLATION
- PRECAUTIONS FOR USE
- HOW TO USE
- TEMPERATURE ADJUSTMENT
- Operation and display panel
- Specification
- Control output
- Wiring diagram
- INSTRUCTION MANUAL CLEANING
- IN CASE OF THE FOLLOWING
- BEFORE REQUESTING SERVICE
- REQUIRED INFORMATION
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
scancool SD 1500 Series Esta Drinks Fridge
SAFETY PRECAUTIONS
-
To ensure proper use, please thoroughly study these SAFETY PRECAUTIONS before operating the Unlt.
-
The purpose of the safety precautions in this manual is to ensure safe and correct use of the unit to minimize risks that could cause serious damage and injury to you or other persons. The safety precautions are divided into WARNINGS and CAUTIONS. Cases, where improper handling of the unit could lead to death or serious injury, are listed under the ‘WARNING” heading. However, the cases listed under the ACAUTION” heading could also lead to serious results. To ensure safety, adhere strictly to both types of safety precautions.
-
Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
-
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilifies, or lack of experience and knowledge, unless they have been given supervision or insfruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
-
Do not damage the refrigerant circult.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
-
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
-
When disposing of the appliance, do so only at an authorized waste disposal centre. Do not expose to flame.
-
Warning: The lamp must not be replaced by the user! If the lamp is damaged, contact the customer helpline for assistance.
-
The A-weighted emission sound pressure level is below 70 dB(A)
-
The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts.
WARNING Improper handling of the unit could lead to death or serious injury.
CAUTION Improper handling of the unit could lead to serious results depending on the circumstances. -
Text set off by the exclamation mark contains information that should be strictly adhered to.
-
After reading the instruction manual, store it an easily accessible place where the user(s) of this product can easily find it.
PRECAUTIONS FOR INSTALLATION
WARNING
Installation should be performed only by the dealer or a qualiied expert.
Attempting to install fhe unif yourself could result in water leakage,
refrigeranf leakage, electrical shock, or tire.
PRECAUTIONS FOR USE
HOW TO USE
BEFORE USE
- Remove the shipping package, face, etc, and leave doors open. Ventilate fora while.
- The unit is cleaned before shipment. However, clean the compartment interior after delivery.
- Please insert the power supply plug into the wall outlet,single-phase to correct the voltage.
- Allow the unit to operate for about 1 hour to cool the compartment before placing items in the cooler. clear
WAIT 5 MINUTES OR MORE BEFORE RE-STARTING
Restarting the unit immediately after it has been turned off may cause fuses
to blow and activate the circuit-breaker, the compressor may be overloaded,
and/or other damage may occur.
TEMPERATURE ADJUSTMENT
Elitech ECS-16 Temperature Controller User Manual
General
- The temperature controller is specially designed for beverage cabinet. It has user menu and administrator menu.
- Control temperature could be set through user menu; and for administrator menu, it has password protection to avoid misoperation. It can switch between heating and refrigeration mode, and the relay capacity is 30A, which could directly drive a single phase 1.SHP compressor. Defrost output is optional and defrost mode could be either natural defrost or in electric defrost (defrost relay needs to be selected). Colorful LED display, and work status is displayed in symbols. It adopts plug-in quick connection terminal, which highly simplify the processing for manufacturers.
Operation and display panel
Specification
- Mounting size : …………………………………………………………………………………………. 71×29 (mm)
- Product size: ……………………………………………………………………………….. 78.5 × 34.5 × 82 mm
Technical parameters
- Measuring rang: …………………………………………………………………………………….. -50℃~+90℃
- Resolution : …………………………………………………………………………………………………………… 1℃
- Accuracy: . …………………………………………………………………… -50℃~50 ℃,±1℃,others, ±2℃
- Cabinet temperature control range: …………………………………………………………… -50℃~85℃
- Power supply: …………………………………………………………………………… 220VAC±10% 50/60Hz
- Power consumption: ……………………………………………………………………………………………. <3W
Output capacity
- Refrigeration: …………………….. 30A/240VAC, directly drive a single phase 1.5HP compressor;
- Defrost : …………………………………………………………………………………….. 5A/250VAC (optional)
- Front panel protection level: ……………………………………………………………………………… IP65 9
- Ambient temperature: ………………………………………………………………………………… 0℃~55℃
- Storage condition : ………………………………………………………………… temperature -25℃~75℃
- Storage humidity: . ……………………………………………………………. 20%~85% (non condensing)
In dicator light status description
Indicator light | Symbol | Status | Meaning |
---|---|---|---|
Setting | SET | ON | Parameter setting |
OFF | Status of temperature measuring and controlling | ||
Control load | out | ON | Control load works |
OFF | Control load stops | ||
FLASH | Control load in time delay | ||
Heating mode | H | ON | Start heating mode |
Refrigeration mode | C | ON | Start refrigeration mode |
Defrost | def | ON | Start defrosting |
Parameter list
Menu | Menu function | Setting range | H1 | H2 | Unit |
---|
User Menu
St| Set temperature| Min. set temperature C3~Max. set temperature C4| 3| 3| ℃
Po| Menu password| 0~99(password is 55, irreversible)| 0| 0| /
Administrator Menu
rd| Temperature hysteresis| 1~15| 4| 6| ℃
C1| Temperature sensor calibration| -10~10| 0| -3| ℃
C2| Control load start delay| 0~60| 1| 2| min
---|---|---|---|---|---
C3| Min. set temperature| -50~St| 0| 0| ℃
C4| Max. set temperature| St~85| 10| 6| ℃
A1| Periodical open time after sensor failure| 1~60| 45| 45| min
A2| Periodical close time after sensor failure| 0~60
0:close control load after sensor failure
| 15| 15| min
d1| Defrost cycle| 0~90
0:Defrost forbidden
| 6| 12| hour
d2| Defrost time| 1~90| 20| 20| min
d3| Display during defrost| 0:Display cabinet temperature
1:Display dF during defrost
2:Display defrost start temperature during defrost
| 2| 2| /
HC| Refrigeration/heating switch| 0:Refrigeration
1:Heating
| 0| 0| /
Keys function
Key operation
User parameter setting
In the status of temperature measuring and controlling, press Set key for
three seconds to enter user parameter setting state, it displays menu St in
the digital tube. At this time, press Set key to display the corresponding
parameter value, and press or to adjust the set temperature, and then press
Set key to return to menu item St.
Enter to the administrator menu setting
In the state of user menu setting, when it displays menu item St in the
digital tube, press to switch to the menu item Po, press Set key to display
00, and press and to adjust it to 55, then press Set key again to return to
menu item Po. At this time, press key to display rd, indicating that it has
entered to the administrator parameter setting status.
If it doesn’t adjust to 55, press Set key to return to menu time Po, then
press the key , it will exit from user parameter setting status and return to
the temperature measuring and control status.
Administrator parameter setting
After enter to the administrator parameter setting, press and to select menu
items (St, Po, rd……);
After select the item, press Set key to enter to the current parameter
setting, press and to adjust parameters, and then press Set key to return to
the menu item.
Exit from parameter setting
Under the status of parameter setting, press key or no key operation within
30s, or if Po is not set as 55, press key when it displays menu item Po (i.e.
password input error), it will save the current parameter value and exit from
parameter setting.
Manual defrost
In the status of temperature measuring and controlling, Press for three
seconds to force the open or close of defrost( d1 is not 0, i.e. defrost is
not forbidden).
Parameter recovery
In the status of temperature measuring and controlling, press key for
10S,display H0 in the digital tube, it will execute one key recovery
operation. It could continue to select the parameter recovery items by
pressing key ,and the selection range is H0~H7,press key to execute the
parameter recovery and then exit,if there is no parameter recovery operation
within 30S,it will automatically exit from the mode without recovery of
parameters.
Note : During the operation of one key recovery, it needs a stable power
supply. If the power supply is not stable, please electrify the controller
again then execute one key recovery.
H0| Give up parameter recovery,no change of each parameter, no display of
parameter recovery success code dr
---|---
H1| Recovery parameter H1, recovery success display dr
H2| Recovery parameter H2, recovery success display dr
H3| Reserved
H4| Reserved
H5| Reserved
H6| Reserved
H7| Reserved
Control output
Refrigeration/heating:
Normal status:
HC=0, refrigeration mode:
When the cabinet temperature is higher than the set temperature+ hysteresis
temperature, and finish the control load start delay time, the refrigeration
will start;When the cabinet temperature is lower than the set temperature, the
refrigeration will close.
HC=1, heating mode:
When the cabinet temperature is lower than the set temperature, and finish the
control load start delay time, the heating will start: When the cabinet
temperature is higher than the set temperature + hysteresis temperature, the
heating will close.
Note: For the initial use of controller, the control output start delay
time is calculated as 3s, and in the future, it is calculated as C2(Control
load start delay) In heating model, it needs to set d1 to 0 (Defrost
forbidden)
Sensor failure:
A2=0, the function of “Run/stop in a proportional time” is canceled, the
control output closes;
A2≠0, the function of “Run/stop in a proportional time” opens, the control
output will run and stop periodically according to the set time after the
sensor fails.
Defrost:
If the defrost cycle is not 0, the controller will start defrost when it
finishes defrost cycle or it can be manually started. Defrost stops when finish
defrost time or it could be manually stopped.
Display during defrost:
- d3=0: Display real time cabinet temperature
- d3=1: Display dF during defrost
- d3=2: Display defrost start temperature during defrost
Code | Reason | Control output | Remark |
---|---|---|---|
E1 | sensor failure | Run/stop control output in a proportional | / |
dF | Defrost | With defrost relay: output defrost | / |
Without defrost relay: off cycle defrost
dr| Parameter recovery| The original parameters will be overwritten by the
selected parameters| Factory operation mode
Wiring diagram
Danger:
Strictly distinguish the power wire, relay output, sensor down-lead and data
line, and the relay could not be overloaded.
Prohibit connecting the wire terminals without electricity cut-off.
Warning:
Prohibit using this unit under the environment of over damp, high temp.,
strong electromagnetism interference or strong corrosion.
Notice:
- The power supply should conform to the voltage value indicated in the instruction, and make sure a steady power supply.
- To avoid the possible interference, the sensor down-lead/data line and power wire should be kept in a proper distance.
DRAIN TRAY
- Defrosting is performed automatically and drain water Is collected In the draln tray.
- Water in the drain tray is evaporated automatically. In humid environments, there will be a large amount of water in the drain tray, so please throw away drain water once a day.
EFFICIENT USE
- To prevent cold air from escaping, open and close the door quickly and keep the door opened for as short a time as possible.
- Please install the unit in a place which is well-ventilated.
SHELF HEIGHT ADJUSTMENT
- The shelf height can be adjusted.
- Arrange the shelves in accordance with the dimensions of the items to be placed in the cooler.
PLACING ITEMS IN THE SHOWCASE
This showcase employs a forced circulation of cold air system. If circulation
of cold air is obstructed, the items will not be adequately refrigerated. Pay
attention to the following points:
- Do not let items obstruct the cold air inlet and suction outlet.
- Place items so that they do not protrude from the shelves. The gap between the shelves and the door is used for circulation of cold air.
- Place items evenly on all shelves.
CLIMATE CLASS
- 32°C+2°C on appliances of climatic class 0,1,2,3,4.6 or 8
- 43°C+2°C on appliances of climatic class 5 or 7
INSTRUCTION MANUAL CLEANING
WARNING
TO prevent any electrical shock hazards or injury by rotating circulation
fan, always disconnect the power cord plug from the wall outlet before
cleaning.
EXTERIOR AND COOLER COMPARTMENT
Wipe witha soft, dry cloth. If very soiled, wipe witha cloth that has been
moistened with a detergent. Then wipe with a cloth that has been dipped in
water.
WARNING:
Do not splash water directly onto the cooler and do not wash with water. Short
circuit and electrical shock could result.
- Clean the cooler regularly to keep it clean at all times.
- Never use polishing powder, soap powder, benzine oil or hot water as these will damage the painting and plastic components.
CHECKS
- To ensure the safety, perform the following checks after cleaning Ols the power cord plug firmly inserfed into a dedicated wall Outlef? Confirm that the plug is not abnormally hot.
- Check the power cord for cracks and damage. Should the slightest irregularity be observed, contact the dealer from whom you purchased this unit or our customer’s service.
IN CASE OF THE FOLLOWING
-
POWER FAILURE
Keep opening and closing of the door to a minimum. Avoid placing new items in the cooler as this will raise the temperature inside the compartment. -
WHEN NOT USED FOR A LONG PERIOD
Remove all items from the compartment and disconnect the power cord plug from the wall outlet. Clean the compartment interior and wipe away all water. To prevent mold formation and bad smell, leave the door open to dry the compartment completely. -
TRANSPORTATION
Disconnect the power cord plug from the wall outlet. When moving the cooler, make sure that the feef do not damage the power cord. Do not let the feet hit against floor steps, thresholds, etc. -
TEMPORARY STORAGE
Affix a piece of wood, etc. Between the door and main unit fo prevent complete closing of the door. Make sure not to store the unused cooler af a location where children play. Should a child enter the compartment and the door is closed, the child may not be able to open the door from the inside.
BEFORE REQUESTING SERVICE
Please check the fllowing items if you encounter problems with the unit. If the problem continues after faking the proper remedial actions, disconnect the power cord plug from the wall outlet. Transfer the items stored in the cooler to a box or other container. Then contact the dealer from whom you purchased this unit and be ready to provide information as listed in “REQUIRED INFORMATION” below.
CAUTION
To prevent any electrical shock hazards, do not disconnect the power cord
plug trom the wal outlet with wet hands.
Light source in this product is replaceable only by a professional.
r
No refrigeration
at all
| e 1s the power supply interrupted?
e 1s the power cord plug disconnected from the wall outlet?
e Are the shop’s power fuses blown and/or the circuit breaker activated?
---|---
Inadequate refrigeration| • Is the temperature setting appropriate?
• Are items obstructing the cold air inlet and suction outlet?
• Are stored items packed too tight?
• Is the door open or is it opened and closed frequently?
• Is the condenser clogged?
Excessive noise| • Are all feet in firm contact with the floor?
• Is the rear panel of the cooler contacting the wall or other objects?
• Are other objects in contact with the cooler?
Condensation on cooler exterior| e Condensation may condense on the exterior and door during hot and
humid days or depending on the place of installation . This occurs when the humidity is high and water particles in the air contact cold surfaces . This is normal.wipe away condensation with a dry c loth.
\,_| ___
Showcase sometimes stop running when thermostat turns off.
REQUIRED INFORMATION
Access to professional repair, such as internet webpages,
addresses, contact details.
Model no: SD 1502 HE
Aftersales service station list:
Address | Scandomestic A/S |
---|---|
Contact Number | 7242 5571 |
Website | Scandomestic.dk |
QR code | 1068734 |
Relevant information for ordering spare parts, directly or through other channels
provided by the manufacturer, importer or authorised representative;
| Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the
appliance, are available;
| 8 years
Instruction on how to find the model information in the product database, as
defined in Regulation (EU) 2019/2019 by means of a weblink that links to the
model information as stored in the product database or a link to the product
database and information on how to find the model identifier on the product.)|
www.scandomestic.dk
Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affliated one of our company when requiring services.
EU DECLARATION OF CONFORMITY
Ref. Ares In accordance with ISO 17050-1:2004