User manual
TRANSPORTATION AND INSTALLATION
Place on level floor and remove the bottom packing, in orderto decrease the
shock and noise.
The angle between the compartment body and groundshould be no more than 45°
Enough space should be left between the freeze and the wall for ventilation.
Place the freezer away from heat source and do not expose to direct sunshine.
Do not install where there is moisture or where it can easily be splashed by
water.
Do not place the freezer in environment prone to freezing.
The appliance should not be used in open air and should not be exposed to
rain.
ADJUSTMENT AND RUNNING
Adjustment of temperature: The storing temperature can be adjusted by the
thermostat of the compartment. The thermostat should be adjusted according to
different environment temperature and the food by rotating the knob of the
thermostat. The knob rotates clockwise from “1” to “7” (or direction arc) and
the inside temperature turns down in summer (anticlockwise rotation) and up in
winter (clockwise rotation). It is usually fixed to a certain point before
leaving the factory. Do not adjust too often or touch the other parts.
Trial running: plug in and wait. The marked drop in temperature within half an
hour indicates that the freezer works properly.
The compressor should be left to run for a period of time (6 hours in summer 4
hours in winter) before putting the foodin.
SAFETY PRECAUTIONS
The freezer should use a single 3-pin socket with (13A) fuse.A multi plug
outlet should not be used.
You should install a suitable automatic voltage regulator not less than 500w
when the voltage is outside the range from 187V to 242V.
The sockets of the freezer should be connected to stable fixed connection.
Under no circumstance should the wiringbe connected to such facilities as
water pipe, gas pipe andso on.
Once power is cut off, wait for at least 5 minutes before plugging in again to
avoid damaging the compressor or thesystem.
Do not put combustible, explosive or volatile dangerous articles, heavily
corrosive acid or alkali of liquid in glassware into the freezer.
Children should be kept away from the freezer to avoid da-mage to the inner
container or any accidents being incurred
If the power cable damages, for avoid dangerous, must bymanufactory or its
maintain a set or similar profession jobthe personnel replaces.
FREEZING METHODS
Do not put too much food into the freezer or exceed the loading line.
Proper space should be allowed between foods to ensure cooling air
circulation.
Never use corrosive detergent, hot water, or washing power to clean the
freezer.
Do not use water to scour the freezer. Do not use hard brushes or wire brushes
to clean the freezer.
Do not use metal or sharp tools for defrosting.
Do not use electric heaters to heat up and defrost.
The green lamp is a power indicating lamp. When the power is on, the lamp will
be on.
Circuit diagram
Model ………………………………………. SD 46 E
Climate classification ………………………….. 4
Anti-shock safety classification ……………… I
Rated voltage …………………………. 220-240v
Rated frequency ……………………………. 50Hz
Rated Current ……………………………… 1,2 A
Refrigerant ……………………………. R290/40g
Model ………………………………………. SD 76 E
Climate classification ………………………….. 4
Anti-shock safety classification ……………… I
Rated voltage …………………………. 220-240v
Rated frequency …………………………… 50Hz
Rated Current ………………………………. 1,2 A
Refrigerant ……………………………. R290/50g
Model ……………………………………… SD 92 E
Climate classification …………………………. 4
Anti-shock safety classification …………….. I
Rated voltage ………………………… 220-240v
Rated frequency …………………………… 50Hz
Rated Current ………………………………. 1,2 A
Refrigerant ……………………………. R290/50g
LED
- Lamp type: LED-light.
- Energy efficiency level: G
- Light source in this product is replaceable only by a professional
TROUBLE SHOOTING:
The design and production comply with the relative security standard of China. If you find it does not work as usual, please examine and handle it according to the following table first. If the situation does not improve, you must contact our aftersale servicecenter or our special repair division to examine and repairthe appliance. The following problems are not causes of breakdown:
There is a sound of liquid flowing in the freezer
It is the sound of refrigerant flowing in the circulating pipeline of the
refrigerating system. It is normal.
Too noisy
The freezer is not installed in a level ground. Change the position.
The refrigerating system does not work for a long time but the inside
temperature is very low
It is an indicator of high quality for its good insulation and low cooling
retention low. It is normal.
Trouble | Possibilities | Check up | Solutions | Remarks |
---|---|---|---|---|
Compressor does not work | Power is off | The fuse is broken | Check the fuse | |
Replace the fuse | If it is necessary, please |
contact after-sales service for repair
The connection between plug and socketis not good| Check the socket| Repair or
replace the socket
The circuit of input and output is out of use| Make sure that the power is on|
Check the circuit with electric instrument
The thermostat knob is not in the proper position| Check the thermostat|
Rotate the thermostat to the proper position| Ask for professionalhelp
Compressor keeps on
working| The temperature inside is too high| Frost on the evaporator is too
thick| Check whether the frost is thicker than6- 8mm| Defrost regularly|
The door is being opened too frequently| | Reduce the times of opening|
Too much food has been stored at once| | Take out some of the food|
The tempera- ture insideis OK| The ambient temperature is too high .while the
thermostat indicates a small number| Make sure whether the knob is indicating
at the”5-6″(ordeeper)| Adjust the thermostatknob| The thermostat knobon”2-
4″is better(or proper)
The thermostat does not work| | Replace the thermostat| Ask for after-sales
service
Too noisy| The floor is not level| Make sure that the freezer is level| Put
pad under the castors|
The screw-in fan or condenser is loose| The screw is loose| Rotate the fixed
screw|
The refrigerating circuits touch each other| | Separate them|
Access to professional repair, such as internet webpages, addresses, contact details.
Model no: SD 46 E
Aftersales service station list:
Address | Scandomestic A/S |
---|---|
Contact Number | 72425571 |
Website | Scandomestic.dk |
QR code | 933269 |
Relevant information for ordering spare parts, directly or through other
channels provided by the manufacturer, importer or authorised representative;|
Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the
appliance, are available;| 8 years
Instruction on how to find the model information in the product database, as
defined in Regulation (EU) 2019/2019 by means of a weblink that links to the
model information as stored in the product database or a link to the product
database and information on how to find the model identifier on the product.)|
www.scandomestic.dk
Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.
Access to professional repair, such as internet webpages, addresses, contact details.
Model no: SD 76 E
Aftersales service station list:
Address | Scandomestic A/S |
---|---|
Contact Number | 72425571 |
Website | Scandomestic.dk |
QR code | 893198 |
Relevant information for ordering spare parts, directly or through other
channels provided by the manufacturer, importer or authorised representative;|
Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the
appliance, are available;| 8 years
Instruction on how to find the model information in the product database, as
defined in Regulation (EU) 2019/2019 by means of a weblink that links to the
model information as stored in the product database or a link to the product
database and information on how to find the model identifier on the product.)|
www.scandomestic.dk
Access to professional repair, such as internet webpages, addresses, contact details.
Model no: SD 92 E
Aftersales service station list:
Address | Scandomestic A/S |
---|---|
Contact Number | /242 55/1 |
Website | Scandomestic.dk |
QR code | 933308 |
Relevant information for ordering spare parts, directly or through other
channels provided by the manufacturer, importer or authorised representative;|
Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the
appliance, are available;| 8 years
Instruction on how to find the model information in the product database, as
defined in Regulation (EU) 2019/2019 by means of a weblink that links to the
model information as stored in the product database or a link to the product
database and information on how to find the model identifier on the product.)|
www.scandomestic.dk
Note: The address or contact phone number of the service site is subject
to change without prior notice. Please confirm whether the service station is
a directly affiliated one of our company when requiring services.
EU DECLARATION OF CONFORMITY
Ref. Ares In accordance with EN ISO 17050-1:2004
Model number (unique identification of the product): | SD 46 E |
---|---|
Name and address of the manufacturer or his authorised representative: |
Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the
manufacturer (or installer):| Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
Object of the declaration (identification of product allowing traceability. It
may include a colour image of sufficient clarity to enable the identification
of the product, where appropriate.)
Product: Commercial Freezer Brand: Scancool
Colour: White
Model name: SD 46 E|
The object of the declaration described in point 4 is in conformity with the
relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the
specifications in relation to which conformity is declared:| EN 55014-1:2017,
EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55014-2:2015, 2014/30/EU, IEC
60335-2-89 :2010, AMD1:2012, AMD2:2015, IEC60335-1:2010, AMD1:2013, AMD2:2016,
EN 60335-2-89:2010 + A1:2016 +A2:2017 EN 60335-1:2012 + A11:2014+ A13:2017 EN
62233:2008, 2019/2018, 2017/1369, 2019/2024, 2021/340, 2021/341, (MD)
2006/42/EC with amendment 2009/127/EC
Where applicable: the notified body … (name, number)… performed …(description
of intervention)… and issued the certificate:|
Additional information:| Commercial box
Ref. Ares In accordance with EN ISO 17050-1:2004
Model number (unique identification of the product): | SD 76 E |
---|---|
Name and address of the manufacturer or his authorised representative: |
Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the
manufacturer (or installer):| Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
Object of the declaration (identification of product allowing traceability. It
may include a colour image of sufficient clarity to enable the identification
of the product, where appropriate.)
Product: Commercial Freezer
Brand: Scancool
Colour: White
Model name: SD 76 E|
The object of the declaration described in point 4 is in conformity with the
relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the
specifications in relation to which conformity is declared:| EN 55014-1:2017,
EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55014-2:2015, 2014/30/EU, IEC
60335-2-89 :2010, AMD1:2012, AMD2:2015, IEC60335-1:2010, AMD1:2013, AMD2:2016,
EN 60335-2-89:2010 + A1:2016 +A2:2017 EN 60335-1:2012 + A11:2014+ A13:2017 EN
62233:2008, 2019/2018, 2017/1369, 2019/2024, 2021/340, 2021/341, (MD)
2006/42/EC with amendment 2009/127/EC
Where applicable: the notified body … (name, number)… performed …(description
of intervention)… and issued the certificate:|
Additional information:| Display Freezer
Ref. Ares In accordance with EN ISO 17050-1:2004
Model number (unique identification of the product): | SD 92 E |
---|---|
Name and address of the manufacturer or his authorised representative: |
Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the
manufacturer (or installer):| Scandomestic A/S
Linavej 20
8600 Silkeborg
Denmark
Object of the declaration (identification of product allowing traceability. It
may include a colour image of sufficient clarity to enable the identification
of the product, where appropriate.)
Product: Commercial Freezer
Brand: Scancool
Colour: White
Model name: SD 92 E|
The object of the declaration described in point 4 is in conformity with the
relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the
specifications in relation to which conformity is declared:| EN 55014-1:2017,
EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55014-2:2015, 2014/30/EU, IEC
60335-2-89 :2010, AMD1:2012, AMD2:2015, IEC60335-1:2010, AMD1:2013, AMD2:2016,
EN 60335-2-89:2010 + A1:2016 +A2:2017 EN 60335-1:2012 + A11:2014+ A13:2017 EN
62233:2008, 2019/2018, 2017/1369, 2019/2024, 2021/340, 2021/341, (MD)
2006/42/EC with amendment 2009/127/EC
Where applicable: the notified body … (name, number)… performed …(description
of intervention)… and issued the certificate:|
Additional information:| Commercial box
Scandomestic A/S · DK-8600 Silkeborg ·CVR No.: 29774242 · Tel.: + 45 7242 5571 · www.scandomestic.dk
Read User Manual Online (PDF format)