FOAMit FI-BP-5N 5 Gallon Lithium Ion Battery Powered Spray Unit Instruction Manual
- September 24, 2024
- FOAMit
Table of Contents
FOAMit FI-BP-5N 5 Gallon Lithium Ion Battery Powered Spray Unit
Safety
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the
instructions before operating the unit may result in personal injury or death
from the improper use or the chemical solution. Anyone handling, operating or
using the unit must read and understand the instructions in the manual. The
buyer assumes all responsibility for safety and proper use in accordance with
the instructions.
The unit is not to be used by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless given supervision or instructed in the safe use of the unit and
understand the hazards involved. Children under 8 years old should be
supervised to ensure they do not play with or handle the unit.
Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical
solution and cause serious injury such as burns, rashes, eye damage, throat or
lung damage and death. Always depressurize and clean the unit after each use.
Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in
scalding, burns, serious injury or death. DO NOT use a solution with a
temperature above 100°F (37.8°C).
Some components may be hot during and after use. Use caution when servicing or
handling the equipment.
Operating the unit when damaged or leaking may result in exposure to chemical
solutions, serious injury or death. Never use the unit if it is damaged or
leaking.
Use of hydrocarbons and flammable products may result in explosions, fire and
serious injury or death. Never use hydrocarbons or flammable products with the
unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating
of mixture may cause it to splatter caustic compounds or release hazardous
fumes, gas and vapors. Always flush the unit with fresh water thoroughly when
switching from an alkaline to an acid or an acid to an alkaline.
Never point the discharge wand at yourself, another person, or any object you
do not want covered in chemical.
Keep battery box lid closed and latched at all times unless accessing battery.
Do not use with lid open or damaged. Do not expose unit to liquids, cleaning
solutions, foam, or rain. The battery pack is not waterproof. Do not submerge
in liquid. If battery pack gets wet, allow to dry before further use.
Using the unit with unapproved devices may result in a risk of fire, shock or
personal injury. Only use with 24V Equip Series compatible equipment.
Store unit and battery indoors in a cool, dry location between 32°-77°F
(0°-25°C) and < 75% relative humidity. Do not store below 32°F (0°C) or above
122°F (50°C). To prevent premature battery failure, do not store battery in
depleted state for long periods of time.
First Aid Instructions
- Failure to follow first aid instructions may result in death or serious personal injury.
- If battery liquid comes in contact with skin, wash immediately with soap and water, then neutralize with lemon juice or vinegar.
- If battery liquid gets in your eyes, flush with clean water for a minimum of 10 minutes, then seek immediate medical attention.
- If battery liquid is swallowed, seek immediate medical attention.
State of California Proposition 65 Warning
- The battery can expose you to chemicals, including cobalt, lithium, manganese, nickel, oxide, and carbon black, which are known to the State of California to cause cancer and reproductive harm. For additional information, go to www.P65Warnings.ca.gov.
NOTICE
The unit is not rated for high-altitude areas of 2000 meters and above.
Servicing or modifying this unit with parts not listed in this manual may
cause the unit to operate improperly. Do not use unauthorized parts when
servicing the unit.
In the presence of radiated RF energies, the charge indicator button can lose
functionality. Refer to the separate manuals supplied with the battery and
charger for additional safety precautions and instructions.
Protect the Environment
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Manufactured by: FOAMit
3833 Soundtech Ct. SE Grand Rapids, MI 49512 US
Product Overview
Requirements
Liquid temperature range | 40-100˚F (4.4-37.8˚C) |
---|---|
Electrical requirements | 120-240 VAC at 50-60 Hz, 3A (GFCI protected outlet) |
for battery charger only
Operating voltage| 24 VDC
Chemical compatibility| Chemical products used with this equipment must be
formulated for this type of application and compatible with unit materials and
pump seals. For more information on chemical compatibility, consult the
manufacturer or SDS for your product or contact our customer service
department.
Specifications
Power type | Lithium-ion battery |
---|---|
Battery charge time | 1 hour 10 minutes |
Battery run time | Up to 45 minutes of continuous use |
Chemical pickup type | Draws from pre-mixed solution |
Number of products unit can draw from | One product |
Suction line diameter | ⅜ in. (9.5 mm) inside diameter |
Capacity | 5 gallons (18.9 liters) |
Discharge line length/diameter | 12 ft. (3.7 m) hose, with 3/8 in. (9.5 mm) |
inside diameter
Discharge wand/tip type| Polypropylene spray gun with 80° fan tip Stainless
steel ball valve (SSBV) with 80° fan tip
Output distance| Up to 5 ft. (1.5 m)
Output volume| 4.9 gal/min (18.5 l/min)
Flow rate*| 0.5 gal/min (1.9 l/min)
Pump seals| Santoprene diaphragm, Viton check seals
Wheel type| Two 4 inch (10.2 cm) non-marking wheels
*Flow rates given are based on chemical with viscosity of water.
Product Components
Get to know the FI-BP-5N components that you will need to use, adjust or assemble.
Back plate assembly
Inside view
-
In-line strainer
-
Electric fluid pump
-
Relay controller
-
Check valve
-
Needle valve
-
Muffler
-
Pressure switch
-
Electric air compressor
-
Backplate thumb nuts
-
Handle
-
Solution tank
-
Cap
-
Discharge wand
-
Trigger gun
-
Discharge hose
-
Power button
-
Needle valve
-
Battery
-
Battery box
Using Your Unit
Operating Instructions
-
Remove battery and charger from packaging.
Battery must be fully charged before use. Refer to the charge level indicator table in battery user manual for more information. -
Once fully charged, insert battery into the receiver until properly secure. Close lid and secure the latch.
Note: Keep battery box lid closed and latched unless accessing battery. Do not operate unit with lid open or damaged. -
Fill tank with pre-mixed solution as directed by the chemical manufacturer, then securely tighten the cap.
-
Press the power button to turn on the unit.
-
Slowly open the discharge ball valve or squeeze trigger handle to begin foaming.
-
While the unit is running and discharging product, adjust the needle valve to regulate the wetness or dryness of the foam following the steps below:
a. Close the needle valve completely in clockwise direction.
b. Open needle valve in counter-clockwise direction 3 complete turns.
c. Continue to open needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency of foam is achieved. -
Close the discharge ball valve, or release trigger handle to stop foaming.
After Use Instructions
Note: For proper handling and disposal procedures refer to chemical SDS. -
Solution should be removed from unit after each use. This can be done in two ways:
a. Unthread cap from top of tank and drain solution into an approved location.
b. Place discharge wand into approved container. Turn the needle valve to the wet setting and activate unit until all solution has been flushed. -
Press power button to turn off unit. Open the discharge ball valve or trigger handle to relieve remaining pressure.
-
Before using unit with another chemistry, thoroughly flush with water.
Maintenance
Performing any maintenance with the unit pressurized, may result in serious injury or death. Always ensure the unit has been depressurized, and battery has been removed before conducting any maintenance. Cleaning and user maintenance shall not be made by children without supervision. Servicing or modifying unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:
- Inspect the pump for wear and leaks.
- Inspect all hoses for leaks or excessive wear. Verify all hose clamps are in good condition and properly secured.
- Check the suction line and strainer for debris. Clean as needed.
- If foam quality beings to decrease, inspect the wadding. Replace as needed.
- Store battery in a half-charged state and maintain battery every 3-6 months.
Servicing Your Unit
To service your unit, refer to the service manual which includes:
- Troubleshooting procedures.
- Detailed parts breakdowns and illustrations.
- Part numbers of serviceable components and assemblies.
Scan this code for
service manual
Documents / Resources
|
FOAMit FI-BP-5N 5 Gallon Lithium Ion Battery Powered Spray
Unit
[pdf] Instruction Manual
FI-BP-5N, FI-BP-5N 5 Gallon Lithium Ion Battery Powered Spray Unit, 5 Gallon
Lithium Ion Battery Powered Spray Unit, Lithium Ion Battery Powered Spray
Unit, Battery Powered Spray Unit, Powered Spray Unit, Spray Unit, Unit
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>