SCANCOOL SF 217 BE Professional Chamber Freezer User Manual

June 2, 2024
SCANCOOL

SCANCOOL SF 217 BE Professional Chamber Freezer

SCANCOOL-SF-217-BE-Professional-Chamber-Freezer-
PRODUCT

Please carefully read the instruction manual before operating the freezer. Please keep it properly for reference.

CAUTION: RISK OF FIRE

This merchandiser contains flammable gas within the insulation foam and must be recycled by a specialist according to all applicable local law.; and regulations. For further information, please consult your local Council.

Safety Instructions

Electrical connecting

The cabinet operates on 220-240V/50Hz. The wall socket should be easily accessible. All earthing requirements stipulated by the local electricity authorities must be observed. The cabinet plug and wall socket should then give correct earthing.If in doubt, contact your local supplier or authorized electrician. The cabinet should be periodically maintained and cleaned. For personal safety, cut off the power supply before maintenance and cleaning. Do not use wet cloth to wipe the electrical components.

  • Do not store or put near flammable, explosive, corrosive articles and volatile liquid.
  • Do not touch any charged components such as plugs, switches, etc. with wet hands, in case of electric shock.
  • Do not damage the power cord or plug. Do not use the plug with loose power cord, in case of fire or electric shock.
  • Do not place a container or heavy items on top of the cabinet, to avoid crushing the roof, or crashing if heavy items fall down, or electricity leakage if water flash on the electronics.
  • Do not climb the cabinet to avoid tipping. Do not lean against the door.

Please remove all packing materials before use, and put the plastic bags out of children’s reach. If the cabinet is not being used, it is recommended to remove the door. This will reduce the possibility of danger to children. If part need to be replaced, please contact the service, do not disassemble them personally. Details concerning precautions during user maintenance, see page 7 Do not exceed a maximum loading of 20 kg per shelf. The installation, handling, servicing and disposal of the appliance shall be carried out according to the instruction specified on page 4to 5 The appliance uses flammable refrigerant R290, the following warnings as below.

WARNING

  • Keep clear of obstruction all ventilation openings in the appliance enclosure.
  • Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacture.
  • Do not use electrical appliance inside the food storage compartments of the appliance.
  • If the supply cord becomes damaged, it must be replaced by an authorized service agent, or similarly qualified person, in order to avoid a hazard.
  • Appliance is designed to be working according to class 4 (ISO climatic classification), wherever the ambient temperature not exceed 30 °C and relative humidity not exceed 55%.

Installation

  • Remove the wooden pallet and the packing. External surfaces are supplied with a protection foil, which must be removed before installation.
  • If the cabinet has been transported, please wait 2 hours before starting up.
  • The cabinet operates on 220-240V/50 Hz. The main electrical connections must be done by skilled electricians.
  • This product must be continuously electrified for 3 ~ 4 hours, when inner temperature is stable, it can store items in batches, to store too many items at once is strictly forbidden, leave some space between items to facilitate air flow inside cabinet, in case that goods are not frozen adequately.
  • The cabinet must be responsible by special person, check operation condition daily, to make sure safe use.
  • When moving the cabinet, tilt angle between bottom of cabinet and floor should not be more than 45 °.
  • When moving the cabinet, lift from the bottom, move it slightly and carefully.
  • During transportation and handling, do not invert the cabinet, lie it down, roll, or squash. Do not step on it and crash.
  • Keep the door, light box and front grill free from force, to avoid these parts to be damaged.
  • Do not expose it to direct sunlight, otherwise, the cabinet may not be cold enough.
  • Place the cabinet in a dry and ventilated place.
  • Keep the cabinet away from strongly heat-emitting sources.
  • This cabinet should not be placed in flammable or corrosive gases in case of an explosion or electric shock.
  • This cabinet should not be placed in the environment with high humidity or splash, in case of electricity leakage.
  • Thermostat has been set at factory. If you need to reset, please operate carefully.
  • The cabinet defrosts automatically. Defrosted water runs to a container placed in the compressor compartment and evaporates.Please do notpress the button to avoid disorder of defrost function.
  • Use the cabinet in room, ambient temperature should not exceed 32℃.

Main Parts

SCANCOOL-SF-217-BE-Professional-Chamber-Freezer-FIG-2

Maintenance and Cleaning

  • Before cleaning, switch the freezer off at the socket.
  • Scrub the inner and outer surfaces with a soft cotton cloth with a few non-corrosive neutral cleaning solution. Rinse with clean warm water and dry with a soft cloth. Do not use harsh chemicals, abrasives, ammonia, chlorine bleach, etc. some of these chemicals may dissolve, and/or damage the freezer.
  • The door gasket is easy to adhere to dust. Gaskets must be kept clean and pliable to assure a proper seal. Petroleum jelly applied lightly on the hinge side of gaskets will keep gaskets pliable and assure a good seal.
  • Do not use water to wash inner tank, and do not use hard brush to clean inner tank.
  • When to stop using the freezer, unplug it from socket. Clean the inner tank and dry it with soft cloth, to keep inside of cabinet dry.

Caution: Disposal of the cabinet must take place in an environmentally correct way. Please note existing regulation on disposal. There may be special requirements and conditions which must be observed.

Troubleshooting

Freezer does not operate

  • Power socket has no electricity, fuse blown.
  • Power socket has power, but the plug is not inserted.
  • Temperature control is set too high for temperature.
  • Voltage is too low.
  • Plug loose.
  • Power switch has not been switched on.

Temperature appears warm

  • Door does not seal well.
  • Door is opened for a long time.
  • Temperature is set too high.
  • Cabinet is in direct sunlight or near a hot object.
  • Overloading

No off for compressor

  • Temperature is set too low.
  • Put too many items at once.
  • Cabinet is put too close to the wall, ambient temperature is high.
  • Cabinet is in direct sunlight or near a hot object
  • Ambient temperature is too high.

Big noise

  • Floor is uneven.
  • Cabinet is not put stably.
  • Cabinet is in touch with the wall or other objects.

Caution

  • In case of failure, please check and troubleshoot according to the instructions.
  • If you cannot locate the reason to failure, please contact your supplier. Please inform model and serial number of the cabinet. You can find this information on the rating label which is placed inside the cabinet in the top right hand side.

Specifications

  • Climate class ……………………………………………………………………………………………………………… 4
  • Electric shock resistance ………………………………………………………………………………………………. I
  • Capacity (L) ……………………………………………………………………………………………………………. 142
  • Rated Voltage (V) ……………………………………………………………………………………………………. 220
  • Frequency (Hz) …………………………………………………………………………………………………… 240-50
  • Temperature (℃) …………………………………………………………………………………………………. -≤-18
  • Weight (kg) ……………………………………………………………………………………………………………… 77
  • External size WDH(mm) ……………………………………………………………………….. 4446161785
  • Refrigerant  ………………………………………………………………………………………………. R290/0,11Kg
  • Hermetically sealed system ………………………………………………………………………………… GWP: 3

The refrigerant used in this appliance is fluorinated greenhouse gases, which can be harmful to the environment and can be responsible for the global warming if it leaks into the atmosphere.

A hermetically sealed system means a system in which all refrigerant- containing parts are made tight by welding, brazing or a similar permanent connection which may include capped valves and capped service ports that allow proper repair or disposal and which have a tested leakage rate of less than 3 grams per year under a pressure of at least a quarter of the maximum allowable pressure.

Caution: This product will be continuously improved. All parameters are subject to change without prior notice.

Packing list

User Manual Shelf Shelf Clip Poly bag Handle Screws
1 5 20 1 1 2

Disposal

The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

UK

Access to professional repair, such as internet webpages, addresses, contact details.
Model no: SF 217 BE

Aftersales service station list
Address Scandomestic A/S
Contact Number 7242 5571
Website Scandomestic.dk
QR code 539543

Relevant information for ordering spare parts, directly or through other channels

provided by the manufacturer, importer or authorised representative;

| Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the

appliance, are available;

| 8 år
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)| www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product): SF 217 BE
Name and address of the manufacturer or his authorised representative:

Scandomestic A/S Linåvej 20

8600 Silkeborg Denmark

This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):| Scandomestic A/S Linåvej 20

8600 Silkeborg Denmark

Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)

Product: Upright Freezer Brand: Scancool

Colour: Black

Model name: SF 217 BE

| SCANCOOL-SF-217-BE-Professional-Chamber-Freezer-
FIG-3
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:| EN 60335-2-89:2010, EN 60335-1:2012, EN

62233:2008, EN 55014-1:2017, EN55014-2:2015, EN61000-3-2:2014, EN61000-3-3:2013, IEC 60335-2-89:2010+A1:2012, IEC 60335-

1:2010+A1:2013, (EU) No 2019/2024

Where applicable: the notified body … (name, number)… performed … (description of intervention)… and issued the certificate:| RoHS
Additional information:|

Scandomestic A/S
Silkeborg, d. 17-06-2021

Anja Hømlund
Product Manager

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SCANCOOL User Manuals