scancool OTC 95 BE 226W 87L Impulse Cooler User Manual

June 3, 2024
SCANCOOL

scancool-logo

scancool OTC 95 BE 226W 87L Impulse Cooler

Proper use

The refrigerated and frozen food cabinet described in this operating manual is intended for storing snacks, cold drinks, dairy products, and frozen foods or ice cream. Do not load the cabinet with non-frozen products and do not try to freeze products in this case. Proper use only means the use as described above, adhering to the specifications on installation, connection, operation, and service. Any other use is regarded as being contrary to specification and is prohibited.

To avoid any damage during the transport or the installation, never tilt the cabinet more than 50°.

Safety regulation

Warming:
Keep ventilation openings in the appliance enclosure or in the structure clear of obstruction.

Warning:
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.

Warming: Do not damage the refrigerant circuit.

If the cabinet is filled with refrigerant Propane (R290) please read carefully the attached Safety Instructions. The type of refrigerant is documented in the cabinet’s type plate. Refrigerating units operating on Propane (R290) may not be placed in an area with sources of ignition (e.g. Unsealed electrical contacts) or where the refrigerant could gather in the event of a leak. The type of refrigerant is indicated on the cabinet’s type plate.  The plug-in refrigerated cabinets as described in this operating manual are designed and manufactured in compliance with international safety regulations. Like any electrical appliance, it must be handled with all due care, particularly with consideration to ensuring electrical safety. To ensure safe operation in all service conditions, the following safety precautions must be observed:

  • The device may not be used by persons with limited physical, sensory or mental skills and /or with no experience and /or knowledge.

  • Never connect the cabinet to the power supply if it is damaged (in transit or otherwise). When in doubt, contact your Service Organization or dealer.

  • Contact your Service Organization if you are in any doubt about the electrical connection, working or safety of your plug-in refrigerated cabinet.

  • The power plug must be connected in the regulation matter and the electrical power supply must be as indicated on the type plate.

  • Never work by yourself on electrical equipment.

  • Electronic and electrical elements (e.g. damaged cable) may only be replaced by a qualified electrician or person with experience in electrical engineering!
    Safety first!

  • If any damage occurs to the power cable, pull the plug to disconnect the cabinet. Please make sure that the cabinet can’t be switched on again. Call your local Service Organization.

  • Damaged fluorescent tubes, starters, and/or tube covers must be replaced immediately. Contact your local Service Organization.

  • When disconnecting the power plug, always pull on the plug itself and never the cable.

  • Remove the cabinet from use if it is not working properly or exhibits any damage. Disconnect the power plug. Transfer the merchandise to other cabinets or a cold room and call your local Service Organization.

General view OTC95

  1. Handle
  2. Load limit line
  3. Air baffle honeycomb
  4. Evaporator (under base plate)
  5. Compressor
  6. Thermostat or electronic controller (Dixell)
  7. Condenser
    • A Cooling air intake
    • B Air outlet

General view STP1309

  1. Handle
  2. Load limit line
  3. Air baffle honeycomb
  4. Evaporator (under base plate)
  5. Compressor
  6. Thermostat or electronic controller (Dixell) 7 Condenser
    • A Cooling air intake
    • B Air outlet

Installation

Single-row line-up
When cabinets are installed side by side, no distance is required between the end walls of the refrigerated cabinets under normal ambient conditions. 5.2 Group installation, back to back
When two STP1309 cabinets are installed back to back, this can be done without a distance between the rear walls.

Requirements for electrical connection
The cabinet is connected by inserting the power plug in a socket.

The cabinet must not be plugged into a multiple-outlet power strip. The socket employed must be firmly installed, properly earthed and separately fuse- protected by a 10A-circuit breaker, type C.
The supply voltage and frequency of the socket must be in accordance with the data shown on the type plate of the cabinet. Therefore, the cross-section of the wires must be increased, if necessary, for long wires to the socket. The local utility company’s regulations on the power connection (e.g. earth-fault protection, additional equipment bonding, remote control switch etc.) must be observed.
If in doubt, consult a qualified electrician.

  • Run the power cables so that they are protected from risk of damage and there is no risk of tripping.
  • Please don’t drill in the outer or inner of the cabinet. This might damage the refrigeration circuit.
  • If necessary, put the plugs of electrically operated accessories (e.g. the display superstructure) into separately secured sockets.
  • The power cable may not come into contact with parts over 75°C.

Starting

Measures prior to Starting
If the cabinet has been sharply tilted while being sited or for mounting of accessories, it must be left to stand for at least three hours before being started to allow the lubricating oil to settle in the compressor! Failure to do so can cause total destruction of the compressor refrigerating system.

Setting into operation

  • Start the cabinet only if it has been installed as described.
  • Plug the power plug (1-1) in the socket (1-2).
  • When selecting the socket, observe the requirements stated in section 4.7. The cabinet must not be plugged into a multiple-outlet power strip.
  • Switch on remote control switch if provided. Starting is signaled by the low running noise of fans and refrigeration system.
  • Customer should close the lids properly. If not, condensation might happen.

Specifications

Type OTC95 STP1309
Length [mm] 775
Width [mm] 850
Height [mm] 920
Display area [m²] 0.38
Useful capacity [l] 125
Weight [kg] 100
Energy consumption [kWh/24h] 5.0

Power consumption

(refrigeration)

| [w]| 275| 600
Power consumption

(defrosting)

| 275| 700
Fusing, (slow)| [A]| 10
Operating voltage| [V/Hz]| 230/50
No. of defrosts| [min./24h]| 6×20| 6×20
Storage temperature| [°C]| +2…+8| +2…+8
Refrigerant| R290 [kg]| 0.07| 0.07
Max. loading capacity of

shelves

| [kg]| 72| 178
Noise level| dB(A)| <70

Troubleshooting

Any trouble occurring might be due to a minor problem that you can correct yourself by following the instructions below. Do not try any further action if the pointers given cannot solve the problem!

  • Repairs on the cabinet must be made only by qualified specialists. Incompetent repair work can cause serious personal danger, contract your Service Organization for any repairs needed.
Trouble Possible cause Corrective measures

The cabinet does not work (no audible running noise or only fan noise audible.)| Automatic evaporator defrosting active or electronic controller switched off.

Power plug not connected or remote control switch (where provided) switched off. Fuse blown, power plug or socket defective.

Condenser fins fouled.

| Nor required, as cooling will switch on automatically again.

●  Insert power plug properly in or switch remote control switch on.

●  Contact your electrician or the Service Organization.

●  Perform maintenance.

Cabinet stops running after

short operation.

| Condenser fins fouled.| ●  Perform maintenance.
Storage temperature is too high.| Automatic evaporator defrosting active.

The ambient temperature too high or the electronic controller is misadjusted. The warm air outlet or another cabinet is

directly taken in as air

| Not required, temporary minor temperature rise during defrosting is normal.

●  Avoid extreme operating environments, and readjust storage temperature.

●  Observe single-row lineup and group installation.

| intake.

Ventilation slots blocked or covered. Lack of air intake due to obstruction of air intake grill.

Condenser fins fouled.

| ●  Keep ventilation slots free.

●  Remove any obstacles in the air intake area.

●  Perform maintenance.

---|---|---
Storage temperature is

too low.

| Incorrect adjustment| ●  Adjust storage temperature in small

increments.

Formation of odor in the

cabinet.

| Drip water gutter under base plate fouled.| ●  Clean.
Condensation on the sliding glass

lids.

| Wrong close of the sliding lids.| ●  Close the lids properly.

Access to professional repair, such as internet webpages, addresses, contact details.

Model no: OTC 95 BE

Aftersales service station list:

Address Scandomestic A/S
Contact Number 7242 5571
Website Scandomestic.dk
QR code 422924

Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised

representative;

| Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the

appliance, are available;

| 8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2024 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)| www.scandomestic.dk

Note:
The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is directly affiliated with one of our companies when requiring services.

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product): OTC 95 BE
Name and address of the manufacturer or his authorised representative:

Scandomestic A/S Linåvej 20

8600 Silkeborg Denmark

This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):| Scandomestic A/S Linåvej 20

8600 Silkeborg Denmark

Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)

Product: Open Top Cooler Brand: Scancool

Colour: Black

Model name: OTC 95 BE

|
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:| EN55014-1:2017, EN 55014-2: 2015, EN 61000-3-

2:2014, EN61000-3-3:2013/EMC directive (2014/30/EU), EN60335-2-89:2010+A1:2016

+A2:2017, EN60335-1:2012+A11:2014

+A13:2017, EN62233:2008, Machinery Directive 2006/42/EC, IEC 60335-2-89:2010, AMD1:2012, AMD2:2015, IEC60335-1:2010, AMD1:2013, AMD2:2016, (EU) 2019/2018, (EU) 2019/2024, 2021/341, 2021/340, EN ISO 23953-2:2015

Where applicable: the notified body … (name, number)… performed … (description of intervention)… and issued the certificate:|
Additional information:| Commercial Cooler

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals