DrayTek VigorSwitch G2100 L2 Managed Switch User Guide

June 9, 2024
DrayTek

VigorSwitch G2100 L2 Managed Switch
User GuideDrayTek VigorSwitch G2100 L2 Managed
Switch

VigorSwitch G2100
L2+ Managed Switch
Quick Start Guide

VigorSwitch G2100 L2 Managed Switch

Version: 1.2
Firmware Version: V2.6.8
(For future update, please visit DrayTek web site)
Date: March 31, 2022

Package Content

DrayTek VigorSwitch G2100 L2 Managed Switch - . Package
ContentThe type of the power cord depends on the country that the switch will be installed.DrayTek
VigorSwitch G2100 L2 Managed Switch - . Package Content
1 If any of these items is found missing or damaged, please contact your local supplier for replacement.

Panel Explanation

DrayTek VigorSwitch G2100 L2 Managed Switch - .Panel
Explanation

LED Status Explanation

RJ 45 LNK/ACT
Port 1 ~ 8| On (Green)| The device is connected with 1000Mbps.
On (Amber)| The device is connected with 10/100Mbps.
Blinking| The system is sending or receiving data through the port.
Off| The port is disconnected or the link is failed.
Port 9 ~ 10
SFP LNK/ACT| On (Green)| The device is connected with 1000Mbps.
On (Amber)| The device is connected with 10/100Mbps.
Blinking| The system is sending or receiving data through the port.
Off| The port is disconnected or the link is failed.
SYS| On (Green)| The switch finishes system booting and the system is ready.
Blinking (Green)| The switch is powered on and starts system booting.
Off| The power is off or the system is not ready / malfunctioning.
PWR| On| The device is powered on.
Off| The device is powered off.
Interface| Description
---|---
RJ 45 LNK/ACT Port 1 ~8| Port 1 to Port 8 can be used for Ethernet connection.
Console| Used to perform telnet command control.
SFPLNK/ACT Port 9 ~ 10| Port 9 to Port 10 are used for fiber connection.
RST| Factory reset button.
Press it to reboot the system. (<5 seconds) The SYS LED will blink too.
Press it to reset the system with factory default settings. (5~20 seconds)
The SYS LED will be off if RST button is pressed between 5 seconds and 10 seconds.
| Power inlet for AC input (100~240V/AC, 50/60Hz).

Hardware Installation

3.1 Network Connection

Before starting to configure the device, you have to connect your devices correctly.
A hierarchical network with minimum levels of devices may reduce the timing delay between server and client station. Basically, this approach will minimize the number of devices in any one path; will lower the possibility of network loop, and will improve network efficiency. If more than two devices are connected in the same network, select one device as a Level 1 device and connect all other devices to it at Level 2. Server/Host is recommended to connect to the Level 1 device. This is generally if no VLAN or other special requirements are applied.
All device ports are in the same local area network. DrayTek VigorSwitch
G2100 L2 Managed Switch - local area network 3.2 Rack–Mounted Installation
The switch can be installed easily by using rack mount kit.

  1. Fasten the rack mount kit on both sides of the VigorSwitch using specific screws.
    DrayTek VigorSwitch G2100 L2 Managed Switch -
VigorSwitch

  2. Then, install the VigorSwitch (with rack mount kit) on the 19-inch chassis by using other four screws.

Software Configuration

DrayTek VigorSwitch G2100 L2 Managed Switch - Software
Configuration

Before using the switch, perform the following steps:
1. Set up a physical path between the configured the switch and a PC by a qualified UTP Cat. 5e cable with RJ-45 connector.
If a PC directly connects to the switch, you have to setup the same subnet mask for PC and the switch. Default values of the managed switch are listed as follows:

192.168.1.224 IP Address
 255.255.255.0 Subnet Mask
Enabled (On) DHCP Client
Username admin Username admin
Password admin Password admin

2. After configuring correct IP address on your PC, open your web browser and access switch’s IP address.DrayTek VigorSwitch G2100 L2 Managed Switch - IP
address The home page of VigorSwitch will be shown as below:  DrayTek VigorSwitch G2100 L2 Managed
Switch - home page Customer Service
If the switch cannot work correctly after trying many efforts, please contact your dealer for further help right away. For any questions, please feel free to send e-mail to support@draytek.com.

GPL Notice
This DrayTek product uses software partially or completely licensed under the terms of the GNU GENERAL PUBLIC LICENSE. The author of the software does not provide any warranty. A Limited Warranty is offered on DrayTek products. This Limited Warranty does not cover any software applications or programs.
To download source codes please visit: http://gplsource.draytek.com
GNU GENERAL PUBLIC LICENSE: https://gnu.org/licenses/gpl-2.0
Version 2, June 1991
For any question, please feel free to contact DrayTek technical support at support@draytek.com for further information.
Be a Registered Owner
Web registration is preferred. You can register your Vigor router via https://myvigor.draytek.com.
Firmware & Tools Updates
Due to the continuous evolution of DrayTek technology, all switches will be regularly upgraded.
Please consult the DrayTek web site for more information on newest firmware, tools and documents. https://www.draytek.com
EU Declaration of Conformity
We DrayTek Corp., office at No.26, Fu Shing Road, HuKou County, Hsin-Chu Industry Park, Hsinchu 303, Taiwan , R.O.C., declare under our sole responsibility that the product

  • Product name: 8+2 Gigabit Switch
  • Model number: VigorSwitch G2100
  • Manufacturer: DrayTek Corp.
  • Address:

No.26, Fu Shing Road, HuKou County, Hsin-Chu Industry Park, Hsinchu 303, Taiwan. is in conformity with the relevant Union harmonisation legislation:
EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU with reference to the following standards

Standard Standard
EN 55032 EN 55032
EN 61000-3-2 EN 61000-3-2
EN 61000-3-3 EN 61000-3-3
EN 55035 EN 55035
EN 62368-1 EN 62368-1 (Second Edition)

DrayTek VigorSwitch G2100 L2 Managed Switch - icon 2

Declaration of Conformity
We DrayTek Corp. , office at No.26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole responsibility that the product

  • Product name: 8+2 Gigabit Switch
  • Model number: VigorSwitch G2100
  • Manufacturer: DrayTek Corp.
  • Address: No.26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan.
  • Importer: CMS Distribution Ltd: Bohola Road, Kiltimagh, Co Mayo, Ireland is in conformity with the relevant UK Statutory Instruments:

The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032) with reference to the following standards:

Standard Version / Issue date
EN 55032 2015+A1:2016 class A
EN 61000-3-2 2014
EN 61000-3-3 2013+A1:2019
EN 55024 2010+A1:2015
EN 62368-1 2014+A11:2017
EN IEC 63000:2018 2018

DrayTek VigorSwitch G2100 L2 Managed Switch - icon 3

Copyrights
© All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders.
Trademarks
The following trademarks are used in this document:
Trademarks

  • Microsoft is a registered trademark of Microsoft Corp.
  • Windows, Windows 8, 10 and Explorer are trademarks of Microsoft Corp.
  • Apple and Mac OS are registered trademarks of Apple Inc.
  • Other products may be trademarks or registered trademarks of their respective manufacturers.

Safety Instructions

  • Read the installation guide thoroughly before you set up the switch.
  • The switch is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the switch yourself.
  • Do not place the switch in a damp or humid place, e.g. a bathroom.
  • Do not stack the switches.
  • The switch should be used in a sheltered area, within a temperature range of 0 to +45 Celsius.
  • Do not expose the switch to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.
  • Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards.
  • Keep the package out of reach of children.
  • When you want to dispose of the switch, please follow local regulations on conservation of the environment.

Warranty
We warrant to the original end user (purchaser) that the switch will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore- store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes.

Regulatory Information

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device may accept any interference received, including interference that may cause undesired operation.

USA Local
Representative| Company name| ABP International Inc.
---|---|---
Address| 13988 Diplomat Drive Suite 180 Dallas TX 75234
ZIP Code| 75234| E-mail| rmesser@abptech.com
Contact Person| Mr. Robert Messer| Tel.| 19728311600

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>