Laserliner ThermoSpot One DERR Llaser User Manual
- June 9, 2024
- Laserliner
Table of Contents
Laserliner ThermoSpot One DERR Llaser
Read the operating instructions and the enclosed brochure „Guarantee and
additional notices“ completely.
Follow the instructions they contain.
This document must be kept in a safe place and if the laser device is passed
on, this document must be passed on with it.]
General safety instructions
-
Attention: Do not look into the direct or reflected beam.
-
The laser may not get into the hands of children!
-
Do not point the laser beam towards persons.
-
If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
-
Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
-
The device must only be used in accordance with its intended purpose and within the scope of the specifications.
Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications. -
A Laser beam switched on
-
B Battery charge
-
C Hold function
-
D Measured value display
-
E Max. value during the measurement
-
F Display lighting
-
G Unit of measurement °C / °F
4 °C / °F
To set the required temperature unit, press and hold the „°C/°F“ button until
the corresponding symbol appears on the display.
Continuous measurement / Hold
For continuous measurement activate the laser (see figure) and keep the button pressed.
Release the button as soon as the target laser pinpoints the measurement location. The measured value is held.
Measurement procedure notice
This infrared temperature instrument detects the temperature of various
surfaces and materials. A built-in sensor head detects the material-specific
infrared rays emitted by every object. The amount of these emissions is
determined by the material‘s emission coefficient (0 … 1). This instrument is
permanently set to an emission coefficient of 0.95, which is applicable to
most organic materials as well as plastics, ceramics, wood, rubber and
stone. Please ensure that the space between the instrument and surface to be
measured is free of disturbances (steam, gas, contamination, glass).
Laser
The laser is a targeting aid to sight the location for the infrared
measurement. Only the surface‘s temperature is measured. Set the optimum
measuring distance for the measured spot (12:1) such that it is completely
within the target object
Technical data
Technical revisions reserved. 04.14
Measurement range | -38 °C … 365 °C (-36.4 °F … 689 °F) |
---|---|
Accuracy | ± 2.5 °C + 0.05 °C / degree (-38 °C … 0 °C) |
± 2.5 °C (0 °C … 365 °C) or
± 2.5 % whichever value is greater
Optic| 12:1 (distance : measured spot)
Resolution| 0.2 °C
Emission coefficient| 0.95
Laser wavelength| 650 nm
Laser type| Laser class 2, < 1 mW
Operating temperature| 0 °C … 50 °C
Storage temperature| -10 °C … 60 °C
Relative humidity| 20% rH … 80% rH, no condensation
Power supply| 2 x 1.5V alkaline batteries (type AAA)
Dimensions (W x H x D)| 40 x 155.5 x 113 mm
Weight (incl. batteries)| 173 g
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
SERVICE
Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
laserliner@umarex.de
Umarex GmbH & Co KG Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: -333 www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>