Laserliner 080.980A DistanceMaster Vision Instruction Manual
- June 9, 2024
- Laserliner
Table of Contents
- Laserliner 080.980A DistanceMaster Vision
- Function / Application
- General safety instructions
- Inserting rechargeable batteries
- KEYPAD
- DISPLAY
- Switch on, measure and switch off
- Settings menu
- Delete the last measured value
- Measuring plane, pin/stop
- Length measurement
- Addition and subtraction of lengths
- min/max continuous measurement
- Area measurement
- Area calculation
- Volume measurement
- Volume calculation
- Area addition / wall surface function
- Angle function
- Pythagoras function 1
- Pythagoras function
- Pythagoras function
- Stake out function
- Timer function
- Camera function
- Digital bubble level
- Memory function
- Important notices
- Error code
- Technical Data
- EU directives and disposal
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner 080.980A DistanceMaster Vision
Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.
Function / Application
Laser distance meter with camera function
- For measuring length, area and volume
- Min/Max continuous measurement, wall surface function, angle function, Pythagoras 1 + 2 + 3, addition and subtraction function, digital bubble level, stake out function and 360° inclination sensor
- Camera function with digital zoom and viewfinder to target the measurement area
General safety instructions
- The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- This device is designed for charging 1.2V AAA rechargeable nickel metal hydride (NiMH) batteries.
- On no account attempt to charge any other batteries as this could irreparably damage the device or cause serious injuries.
- Only charge rechargeable batteries of the same size, of the same type, same capacity and from the same manufacturer together.
- Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Tampering with (making changes to) the laser device is not permitted.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
Safety instructions
Dealing with electromagnetic radiation
-
The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
-
Local operating restrictions – for example, in hospitals, aircraft,
petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference. -
The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Inserting rechargeable batteries
Open the battery compartment and insert the rechargeable batteries (3x NiMH,
type AAA) as indicated by the installation symbols.
Be sure to pay attention to polarity. The rechargeable batteries can be
charged in the device with the supplied USB charging cable.
- Laser reception field
- Display
- Connection socket for USB charger
- Battery compartment (backside)
- Hinged pin
- Laser outlet
- Camera
KEYPAD
- a ON / laser on / measure / min/max continuous measurement
- b Stake out function
- c Subtraction function / Decrease value / view saved measurements
- d Settings menu / Confirm
- e Length / area / volume / wall surface function
- f Timer function / Measurement point (reference) front / thread / rear / pin g Camera function
- h Addition function / Increase value / view saved measurements
- i Angle function / Pythagoras 1 + 2 + 3
- j OFF / delete last measurement values
- k Memory / Digital bubble level
DISPLAY
- l Laser active
- m Battery symbol
- n Set measuring function
- Measurement point (reference) front / thread / rear / pin
- p Intermediate values / min/max values
- q Measurement values /Measurement results
Switch on, measure and switch off
Settings menu
Delete the last measured value
The device starts up with the last setting.
Measuring plane, pin/stop
For measurements out of a corner, fold down the pin and select the „measurement plane PIN“ setting.
For stop measurements move the pin to the side and select the „measure-ment plane REAR“ setting.
Length measurement
Addition and subtraction of lengths
Further lengths are added by pressing the DIST button.
min/max continuous measurement
The LC display shows the max value, the min value, the differential value and the current value.
Area measurement
The room perimeter is additionally shown on the LC display.
Area calculation
Volume measurement
Volume calculation
Area addition / wall surface function
Angle function
The measurement results are determined automatically by the 360° inclination sensor.
The back of the device can be used as a reference surface for measuring angles.
Pythagoras function 1
Pythagoras function
Pythagoras function
Stake out function
- To reach the target move the device in the direction of the arrow
- Target reached
- To reach the target move the device in the direction of the arrow
Timer function
Camera function
Digital bubble level
The digital bubble level is used to align objects.
Memory function
The device has 50 storage locations.
Important notices
-
The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement. -
The device compensates the measurement for different room temperatures. Therefore allow the device a brief adaptation period when changing locations with large temperature differences.
-
The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
-
The measurement results of outdoor measurements may be influenced or falsified by rain, fog and snow.
-
In unfavourable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.
-
Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.
-
Measurements made through glass (window panes) can falsify measurement results.
-
An energy-saving function switches the device off automatically.
-
Clean with a soft cloth. Water may not be allowed to penetrate the housing.
Error code
- Err 1: Received signal too weak
- Err 2: Received signal too strong
- Err 3: Replace the battery
- Err 4: Error in memory
- Err 5: Error in calculation with Pythagoras‘ theorem
- Err 6: Outside the measuring range
- Err 7: Error in camera
- Err 8: Error in inclination sensor
Technical Data
Technische gegevens (Technische veranderingen voorbehouden. 18W25)
Afstandsmeting
Nauwkeurigheid (karakteristiek)*| ± 2 mm
Meetbereik (binnen)**| 0,05 m – 80 m
Hoekmeting
Meetbereik| ± 90°
Laserklasse| 2 < 1 mW
Lasergolflengte| 635 nm
Werkomstandigheden
| -0°C…40°C, Luchtvochtigheid max. 20…85% rH, niet-condenserend, Werkhoogte
max. 2000 m boven NAP (Nieuw Amsterdams Peil)
Opslagvoorwaarden| -20°C…60°C, Luchtvochtigheid max. 80% rH
Automatische uitschakeling| instelbaar
Stroomverzorging| 3 x nikkel-metaalhydride (NiMH) batterijen (accu‘s), typ AAA
1,2V
Afmetingen (B x H x D)| 58 x 135 x 30 mm
Gewicht (incl. batterijen)| 210 g
- measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces.
** at max. 10,000 lux
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=dimavi
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>