- DIMENSION
- Function/Application
- General safety instructions
- Safety instructions
- Safety instructions
- Information on maintenance and care
- Calibration
- Inserting batteries
- ON / OFF
- Infrared temperature measurement / continuous measurement / Hold
- Infrared temperature: Setting the emissivity
- Emission coefficient tables
- Infrared temperature: MAX/MIN temperature
- Room climate – measured values
- Condensation warning
- Thermal bridge warning
- Data transfer
- Application (app)
- Technical data
- EU directives and disposal
- CondenseSpot Pro
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner CondenseSpot Pro Temperature
DIMENSION
Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Function/Application
The CondenseSpot Pro is an infrared temperature measuring device with integrated hygrometer and a Bluetooth®* interface for transferring measured data. Non-contact temperature measurement of surfaces is realised by measuring and evaluating the amount of electromagnetic energy in the infrared wavelength range. The device can also be used to measure all relevant climate data and calculate the dew point. This makes it possible to assess thermal bridges and condensation moisture.
General safety instructions
- The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
- Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
- Do not use the laser at eye level (1.40…1.90 m)
- Tampering with (making changes to) the laser device is not permitted.
Laser outlet
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Safety instructions
Dealing with RF radiation
- The measuring device is equipped with a wireless interface.
- The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
- Umarex GmbH & CO. KG hereby declares that the CondenseSpot Pro radio equipment meets the requirements and other specifications of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=AJH
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Calibration
The measuring device must be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend carrying out calibration once a year. Contact your distributor or the UMAREX-LASERLINER service department.
- LC display
- Set emissivity factor
- Alarm function ON/OFF
- Humidity / ambient temperature sensor
- Infrared sensor
- 8-point laser circle outlet
- Switch between ambient/dew point temperature / MIN/MAX temperature
- ON / trigger
- Battery compartment
- 1/4“ tripod threads
- a Condensation warning
- b Bar graph, condensation moisture indicator
- c Relative humidity measured value
- d Measured value in selected mode (MIN / dew point temperature) / emissivity factor display
- e Measure value in selected mode (MAX / ambient temperature)
- f Measured value, infrared temperature
- g Measurement °C
- h Battery charge
- i Laser beam switched on, temperature measurement (infrared)
- j Hold function
- k Thermal bridge warning
- l Bluetooth®* function active
- m Alarm function deactivated
- n Alarm function active
Inserting batteries
Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.
ON / OFF
The device can also be switched on with the alarm function button (3). No measurement is triggered and the last measured values are displayed.
Auto switch-off after 30 seconds.
Make sure that the humidity/ambient temperature sensor (4) is folded in during transport
Infrared temperature measurement / continuous measurement / Hold
For continuous measurement activate the laser (see figure) and keep the button pressed.
Release the button as soon as the target laser pinpoints the measurement location. The measured value is held (Hold).
Infrared temperature: Setting the emissivity
An integrated sensor head detects the material/surface-specific infrared
radiation emitted by all objects. The level of these emissions is determined
by the specific emissivity of the material (0,01 to 1,00).
After switching on for the first time, the device is preset to an emissivity
factor of 0.95, which is suitable for most organic materials and non-metals
(plastics, ceramics, wood, rubber, paints, varnishes and stone). For materials
with different emissivity factors, refer to the table under Point 6.
Wherever possible, paint or matt black stickers can be applied on non-coated
metals and metal oxides, which due to their low, temperature-unstable
emissivity are suitable for IR measurement only for a limited extent, as well
as on surfaces with unknown emissivity in order to set the emissivity factor
to 0.95. If this is not possible, use a contact thermometer.
The emissivity last selected is set after the device is switched on. Check the emissivity setting before each measurement.
Emissivity factor setting
Emission coefficient tables
Reference values with tolerances
Metals|
---|---
Alloy A3003 Oxidised Roughened|
0.20
0.20
| | Iron Oxidised With rust|
0.75
0.60
| | Steel
Alloy (8% nickel,
18% chromium) Galvanised Oxidised
Heavily oxidised Freshly rolled Rough, flat surface Rusty, red
Sheet, nickel plated Sheet, rolled
Stainless steel
|
0.35
0.28
0.80
0.88
0.24
0.96
0.69
0.11
0.56
0.45
|
Aluminium Oxidised Polished|
0.30
0.05
| Iron, cast Non-oxidised Molten mass|
0.20
0.25
|
Brass Polished Oxidised|
0.30
0.50
| Iron, forged
Matt
|
0.90
|
Lead
Rough
|
0.40
|
Chromium oxide| 0.81|
Copper Oxidised Copperoxide|
0.72
0.78
| Platinum
Black
|
0.90
|
Zinc
Oxidised
|
0.10
|
Steel
Cold rolled Ground plate Polished plate
|
0.80
0.50
0.10
|
Inconel Oxidised Electropolished|
0.83
0.15
|
Nonmetals|
---|---
Asbestos| 0.93| | Gravel| 0.95| | Paper
All colours
|
0.96
|
Asphalt| 0.95| Grit| 0.95|
Basalt| 0.70| Gypsum| 0.88| Plastic Translucent PE, P, PVC|
0.95
0.94
|
Brick, red| 0.93| Gypsum cardboard| 0.95|
Carborundum| 0.90| Heat sink
Black, anodized
|
0.98
| Quartz glass| 0.93|
Cement| 0.95| Rubber Hard Soft, grey|
0.94
0.89
|
Ceramics| 0.95| Human skin| 0.98|
China Brilliant white With glaze|
0.73
0.92
| Ice
Clear
With heavy frost
|
0.97
0.98
|
Sand| 0.95|
Screed| 0.93|
Clay| 0.95| Laminate| 0.90|
Snow| 0.80|
Coal
Non-oxidised
|
0.85
| Lime| 0.35|
Soil| 0.94|
Lime malm brick| 0.95|
Tar| 0.82|
Concrete, plaster, mortar| 0.93| Limestone| 0.98|
Tar paper| 0.92|
Cotton| 0.77| Marble
Black, dull finish Greyish, polished
|
0.94
0.93
|
Transformer paint| 0.94|
Earthenware, matt| 0.93|
Wallpaper, light-coloured| 0.89|
Fabric| 0.95|
Masonry| 0.93| Water| 0.93|
Glass| 0.90|
Paint
Black, matt Heat-resistant White
|
0.97
0.92
0.90
| Wood Untreated Beech, planed|
0.88
0.94
|
Glass wool| 0.95|
Graphite| 0.75|
Infrared temperature: MAX/MIN temperature
MAX/MIN mode refers to the infrared temperature and shows the maximum and minimum infrared temperature. The MAX/MIN values are determined while measuring when the trigger (8) is pressed. The value is deleted and calculated again at the start of a new measurement or by pressing the trigger (8).
Room climate – measured values
The measuring device features a fold-out sensor that measures the ambient temperature and relative humidity while also calculating the dew point temperature. By folding out the sensor, the improved through-flow of air speeds up the measurement procedure.
When changing location and/or where there are large differences in the room climate, it is important to give the measuring device time to adapt until the measured values in the display have stabilized.
The measured ambient temperature and relative humidity values are and is not dependent on when the trigger button is pressed.
Condensation warning
The dew point temperature is the point the temperature must drop below for the air to precipitate its water vapour in the form of droplets, mist or dew. Condensation water therefore occurs for example when the temperature of an inside wall or window reveal is lower than the dew point temperature of the room. These areas are then damp and are a breeding ground for mildew/mould with possible material damage.
The CondenseSpot Pro calculates the dew point with the integrated sensors for ambient temperature and relative humidity. At the same time, the surface temperature of objects is determined with the aid of infrared temperature measurement. By comparing these temperature it is possible to identify areas that are exposed to the risk of condensation moisture. The condensation moisture indicator (b) displays the result in the form of a bar graph, supported by visual and acoustic signals indicating the high probability of condensation moisture occurring.
The condensation moisture indicator (b) is shown in all modes.
The device therefore constantly shows the risk level of condensation moisture.
The visual and acoustic signals can be turned off by pressing the alarm
function button (3). The symbols “ ” (m) and “ ” (n) indicate whether the
alarm function is active or not.
Thermal bridge warning
In relation to buildings, the term thermal bridge refers to an area, e.g. an inside wall, at which heat is transferred outwards faster than at the rest of the inside wall. When viewed from the inside, the temperature of this area is lower than the surrounding areas and when viewed from outside higher than the surrounding areas. This often indicates faulty or inadequate insulation.
For this purpose, the CondenseSpot Pro compares the ambient temperature with
the surface temperature. If there are large differences in both temperatures,
the device will trigger warnings in 2 stages:
The “ ” symbol flashes at the threshold or the display illumination changes to
‘blue’ or ‘red’ if the differential is significant.
The visual and acoustic signals can be turned off by pressing the alarm function button (3). The symbols “ ” (m) and “ ” (n) indicate whether the alarm function is active or not.
Data transfer
The device features a Bluetooth® function that enables wireless data transfer
to mobile devices with a Bluetooth® interface (such as a smartphone or
tablet).
The system prerequisites for a Bluetooth® connection are specified at
http://laserliner.com/info?an=ble
The device can set up a Bluetooth® connection with Bluetooth 4.0 compatible
devices.
The range is set to a maximum distance of 10 m from the terminal device and
greatly depends on the ambient conditions such as the thickness and
composition of walls, sources of interference as well as the transmit /
receive properties of the terminal device.
Once it has been activated, Bluetooth®* remains switched on indefinitely as
the radio system is designed with exceptionally low power consumption.
A mobile device can link up to the active measuring device via an app.
Application (app)
An app is required to use the Bluetooth®* function. You can download the app from the corresponding stores for the specific type of terminal device:
Make sure that the Bluetooth®* interface of the mobile device is activated.
After starting the app, a connection can be set up between a mobile device and
the measuring device. If the app detects several active measuring devices,
select the matching device.
This measuring device can be connected automatically the next time it is
switched on.
- The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.
Technical data
(Technical revisions reserved. 20W07)
Technical data (Technical revisions reserved. 20W07)
Measured variable| Infrared temperature, humidity,
ambient temperature, dew point temperature
Functions| Hold, min./max., condensation warning, thermal bridge warning
Measuring range ambient temperature| -20°C … 65°C
Accuracy ambient temperature| 0°C … 50°C (± 1°C); <0°C and >50°C (± 2.5°C)
Resolution ambient temperature| 0,1°C
Measuring range infrared temperature| -40°C … 550°C
Accuracy infrared temperature
| -40°C … 0°C (± (1°C + 0.1°C/1°C))
0°C … 30°C (± 1°C or ± 1%, depending on the higher value)
30°C (± 2°C or ± 2%, depending on the higher value)
Resolution infrared temperature| 0,1°C
Measuring range humidity (relative)| 1% … 99%
Accuracy (absolute) Humidity (relative)| 20% … 80% (± 3%)
<20% and >80% (± 5%)
Humidity resolution (relative)| 0,1%
Measuring range dew point temperature| -50°C … 50°C
Accuracy dew point temperature
| 20% rH … 30% rH (± 2,5°C)
31% rH … 40% rH (± 2°C)
41% rH … 95% rH (± 1,5°C)
Resolution dew point temperature| 0,1°C
Optics| 12:1 (12 m distance : 1 m measured spot)
Emission coefficient| adjustable, 0.01 … 1.00
Laser| 8-point laser circle
Laser wavelength| 650 nm
Laser class| 2 / < 1 mW (EN 60825-1:2014/AC:2017)
Power supply| 2 x 1,5V LR6 (AA)
Operating time| approx. 20 hours
Operating conditions| 0°C … 50°C, max. humidity 80% rH, no condensation,
max. working altitude 2000 m above sea leve
Storage conditions| -10°C … 60°C, max. humidity 80% rH, no condensation
Radio module operating data| Bluetooth LE 4.x interface; Frequency band: ISM
band 2400–2483.5 MHz, 40 channels; Transmission power: max. 10 mW; Bandwidth:
2 MHz;
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
Dimensions (W x H x D) / Weight| 150 x 90 x 60 mm / 380 g (incl. batteries)
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AJH
CondenseSpot Pro
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932
638-333 info@laserliner.com
Umarex GmbH & Co. KG Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References