Laserliner Thermo Visualizer Pocket Temperature Instruction Manual
- June 9, 2024
- Laserliner
Table of Contents
- Laserliner Thermo Visualizer Pocket Temperature
- FEATURES
- Function / Application
- General safety instructions
- Standard measurement view
- Inserting batteries
- Media gallery/playback mode
- To delete recording
- Auto power off
- Data transfer
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner Thermo Visualizer Pocket Temperature
FEATURES
WARNING: Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Function / Application
The thermal imaging camera provides visualisation of tempera-ture curves, energy losses, thermal bridges, electrical overloads and moisture build-up. The infrared image, digital image and mix image allow the user to have a flexible illustration of the area under inspection. Images are stored on exchangeable Micro-SD cards. The device features a USB interface and a high- contrast, colour TFT display.
General safety instructions
-
The device must only be used in accordance with its intended purpose and within the scope of the specifications.
-
The measuring tools and accessories are not toys.
Keep out of reach of children. -
Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifi-cations.
-
Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
-
The device must no longer be used if one or more of its functions fail or the battery charge is weak.
Safety instructions
Dealing with electromagnetic radiation
-
The measuring device complies with electromagnetic compatibility regulations and limit values in
accordance with EMC-Directive 2014/30/EU. -
Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
-
The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
ON/OFF
- 1,8“ colour display
- Menu navigation / select digital image, overlay infrared / digital image
- Menu / Control menu (Confirmation)
- Menu navigation /select digital image, overlay infrared / digital image
- Battery compartment
- Shaft
- Mini USB interface
- Micro-SD card slot Control menu (cancel / back)
- Infrared sensor
- Digital camera
- Trigger: save image
Standard measurement view
-
Battery charge indicator
-
Micro-SD card not inserted
-
Temperature at centre
of image -
Min. temperature
-
Max. temperature
-
Thermography image
Main Menu
- Change color palette
- Set emissivity coefficient
- Open media gallery / Delete images from micro-SD card
- Auto shutdown
- Set date/time
Inserting batteries
Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.
ON / OFF
Inserting micro-SD card
To insert a micro-SD card, first open the rubber cover and then insert the
memory card as illustrated. You cannot record anything without a storage
medium.
WARNING: The device must be swit-ched off before removing the micro-SD.
Main menu: General and measurement-specific settings can be made in the
main menu. The menu is controlled with the four buttons (3, 4, 5, 8
).
Colour ranges IR image: You can choose from several standard colour ranges to represent the measured infrared temperatures. Depending on the colour palette, the measured temperatures are adjusted within the cur-rent image section and displayed in the respective colour space.
Emissivity coefficient
The level of infrared emissions given off by everything depends on the
specific material and surface. This factor is determined by the emissivity
coefficient (0.10 … 1.0). For
accurate measure-ments, it is absolutely essential that the emissivity
coefficient is set first. The emissivity coefficient can either be custom set
or selected from the predefined emissivity coefficients from the list
.
Emission coefficient tables: Reference values with tolerances
Media gallery/playback mode
All image data recorded with the ThermoVisualizer Pocket is available in the media gallery.
To delete recording
WARNING: The files are deleted immediately. There is no prompt to confirm deletion.
Auto power off
The device switches off automatically after a set period of inactivity.
Date / Time
Image modes
There are 6 image modes to choose from.
- A. IR image (Thermal image)
- B. – E. Digital image with IR image overlay (MIX), 4 stages
- F. Digital image (black/white)
Data transfer
Data saved on the micro-SD card can be transferred to PC either with a suitable card reader or via the mini-USB port. Please refer to the manual supplied with your card reader for information about connecting your card adapter or card reader to a PC.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device must be calibrated and tested on a regular basis to
ensure it is accurate and working properly. We recommend carrying out
calibration once a year. Contact your distributor or the UMAREX-LASERLINER
service department.
EU directives and disposal
- This device complies with all necessary standards for the free movement of goods within the EU.
- This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
- Further safety and supplementary notices at: http://laserliner.com/info?an=AKA
References
Read User Manual Online (PDF format)