JULA 071017 Compressed Air Staple Gun Instruction Manual

June 4, 2024
JULA

JULA 071017 Compressed Air Staple Gun

Care for the environment!
Recycle discarded product in accordance with local regulations.

RIGHTS

  • Jula reserves the right to make changes.
  • For latest version of operating instructions, see www.jula.com

EU DECLARATION OF CONFORMITY

JULA 071017 Compressed Air Staple Gun-fig2
JULA 071017 Compressed Air Staple Gun-fig3

SAFETY INSTRUCTIONS

Read these instructions carefully before use!
WARNING! Always take basic safety precautions when using compressed air tools to safeguard against the risk of personal injury. This power tool is intended for specific applications. The equipment MUST NOT BE MODIFIED and/or used for anything but its intended purpose. Contact your dealer if you have any questions about using the equipment.

  • Keep the work area clean. Cluttered work areas increase the risk of injury.
  • Keep children away from the work area. Do not allow children to operate the tool.
  • Never use the tool if you are under the influence of alcohol, medication or drugs. If you are taking medication, read its warning text to check whether it may affect your judgement and reflexes. Do not use the tool if you are in any doubt.
  • Wear eye protection. Safety glasses must meet ANSI Z87.1 standards. Safety glasses will protect against flying particles from in front and from the sides. Wear eye protection when you are loading, using or servicing the tool.
  • Wear ear protection. High noise levels in the work area can cause hearing impairment.
  • Do not use oxygen, flammable gases, gases in cylinders or pressurized gases to power the tool. The tool can explode and cause serious injuries.
  • Wear appropriate clothing. Wear protective clothing and non-slip shoes or safety shoes when you are working with the tool. Do not wear loose-fitting clothing or jewellery. They can get caught in moving parts. Wear a hair net to prevent your hair from becoming caught in the tool.
  • Do not fire the tool at hard materials. Do not attempt to fire the tool at hard or fragile materials such as concrete, steel or tiles.
  • Stand correctly when using the tool. Always maintain a firm footing and good balance in order to avoid injuries.
  • Check for damaged parts. Carefully check that none of the parts are damaged before using the tool.
  • Replacement of parts and accessories. Only use approved spare parts and accessories for servicing.
  • Pay attention to what you are doing. Always be careful when using the equipment. Use your common sense. Do not use the tool when you are tired.
  • Storing the tool. When not in use, store the tool in a dry place, properly cleaned and assembled, to reduce the risk of corrosion. Keep out of the reach of children.
  • Extension cord for outdoor use. If using the compressor outdoors, only use an earthed extension cord intended for outdoor use. See the manufacturer’s instructions on the required cross-section area for the compressor’s power consumption.
  • Take care with the air hose and its connections. Do not trip over the hose. Check that all connections are properly tightened.
  • Never point the tool at yourself or others when it is loaded.
  • Use the correct compressed air connection. It must not be possible for the connection on the tool to be pressurized after the compressed air supply has been disconnected. If you use the wrong connection, the tool can be pressurized after the compressed air supply has been disconnected, and the fasteners can still be fired.
  • When you connect compressed air, the tool can fire fasteners. You must therefore remove all fasteners before connecting compressed air.
  • Do not squeeze the trigger and the safety mechanism when you are loading fasteners.
  • If fasteners become stuck, disconnect the compressed air supply and remove the jammed fasteners.
    WARNING! Warnings and instructions in this manual do not cover all the situations that could possibly arise. The person operating the tool must use common sense and care.

TECHNICAL DATA

  • Min. operating air pressure: 4,2 kg/cm2
  • Max. operating air pressure: 7 kg/cm2
  • Staple length: 1/4″ – 5/8″
  • Staple size: 21 gauge
  • Staple capacity: 150
  • Air intake: 1/4″ NPT
  • Air consumption: 1.6 CFM
  • Sound power level, LwA: 105,7 dB(A), K= 1,5 dB
  • Sound pressure level, LpA: 82,7 dB(A), K= 1,5 dB
  • Vibration level: 1,56 m/s2, K= 1,5 m/s2
  • Weight: 0.9 kg

Always use hearing protection!

  • The declared vibration value, which has been measured by a standardised test method, can be used to compare different tools with each other and for a preliminary assessment of exposure.
  • WARNING! The actual vibration level when using power tools may differ from the specified maximum value, depending on how the tool is used. It is therefore necessary to determine which safety precautions are required to protect the user, based on an estimate of exposure in actual operating conditions (taking into account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in addition to the start-up time).

DESCRIPTION

When unpacking, use the list below to check that all the parts are included. Contact Customer Services if any parts are missing or damaged.

  • Staple gun
  • S3 hex key
  • S4 hex key
  • Manual

ILLUSTRATIONS

ASSEMBLY

The compressed air tool is supplied fully assembled. Before using the tool, connect the compressed air supply and the required compressed air accessories. See fig. 1 for recommended accessories and order of connection. Check that the air hose is not pressurised when you install or dismantle adapters for the compressed air supply.

Connect the tool to the compressed air supply

  1. Check whether the tool needs to be lubricated. If necessary, add two drops of oil into the compressed air connection, see fig. 2. If you are using a lubricator, check whether you need to top up with oil.
  2. Turn on the compressor and set the correct pressure on the regulator for the type of fastener being used.
  3. Connect the tool to the compressed air supply (see recommended setting).

Loading fasteners

  1. Press down the lock to release the movable magazine and pull out the magazine fully, see fig. 3.
  2. Place a set of fasteners of the right type and size in the fixed magazine. Up to 150 fasteners can be loaded in the magazine. Press the movable magazine forwards until it locks into place.

OPERATION

Use a sample piece to check how deep the fasteners are driven in before you start using the tool. If the fasteners are driven in too deep or not deep enough, adjust the air pressure using the regulator.

  1. Connect the tool to the compressed air supply. Check that the air pressure is within the correct interval (see Technical Data).
  2. Load fasteners as instructed above in the ‘Loading fasteners’ section.
  3. Hold the housing and press the drive control against the work surface. Check that the tool is straight and then gently squeeze the trigger to fire a fastener.
  4. Lift the tool from the work surface.

MAINTENANCE

  • Regular (although not excessive) lubrication is important in order for the tool to work. Oil that is applied through the air intake lubricates the internal parts. We recommend that you install a lubricator, although you can also lubricate manually each time before using the tool as well as after 1 hour of continuous use. You only need to apply a couple of drops of oil each time. Excess oil gathers on the inside of the tool and is blown off during the next blow-off cycle. ONLY USE COMPRESSED AIR OIL Do not use solvents or additives, as these cause the seal in the tool to wear prematurely.
  • Lubricate all moving and rotating parts with a little oil.
  • Dirt and water in the compressed air are common causes of compressed air tools becoming worn. A filter/lubricating unit provides improved performance and a longer life. The filter must have the correct flow capacity.
  • Keep cutting tools sharp and clean for better and safer work. Do not use a flammable cleaning solution.
    IMPORTANT! Such solutions can damage the O-ring and other parts of the tool, and should only be used if necessary. DO NOT IMMERSE THE TOOL.

TROUBLESHOOTING

Stop using the tool immediately if any of the following problems occur. Serious personal injury can otherwise occur. Repairs and replacements may only be performed by authorised personnel or an approved service centre.

PROBLEM CAUSE ACTION
Air leak by the trigger 1.         The O-ring in the trigger valve is

damaged.

2.         The trigger valve head is damaged.

3.         The valve spindle, seal or

O-ring in the trigger is damaged.

| 1.         Check and replace the O-ring.

2.         Check and replace the valve head in the trigger.

3.         Check and replace the valve spindle, seal

or O-ring in the trigger.

Air leak between housing and drive control| Damaged piston, O-ring or shock absorber.| Check and replace the O-ring or shock absorber.
Air leak between

housing          and cylinder head

| 1.         Loose screw connection.

2.         Damaged gasket.

| 1.         Tighten screw connections.

2.         Check and replace gasket.

The    fastener    is

driven      in      too deeply

| 1.         Worn shock absorber.

2.         Air pressure too high.

| 1.         Replace shock absorber.

2.         Correct the air pressure.

Works slowly or without power| 1.         Too little oil.

2.         Insufficient compressed air supply.

3.         Damaged    spring    in    the cylinder head.

4.         Blow-off   in    the    cylinder head blocked.

| 1.         Lubricate in accordance with instructions.

2.         Check the compressed air supply.

3.         Replace the spring.

4.         Replace damaged internal parts.

The     tool    skips over fasteners| 1.         Worn shock absorber or damaged spring.

2.         Dirt in the drive control.

3.         Insufficient compressed air supply.

4.         Worn or dry O-ring on the piston.

5.         Damaged O-ring on the trigger valve.

6.         The    cylinder    head    seal leaks.

| 1.         Replace the shock absorber or feed spring.

2.         Clean the drive control’s drive duct.

3.         Check hose and compression connections.

4.         Replace or lubricate the O-ring.

5.         Replace the O-ring.

6.         Replace the seal.

Fasteners      have become caught| 1.         Worn controller.

2.         Damaged     fasteners     or

fasteners of the wrong size.

3.         Loose   screw  connections

for magazine or front plate.

4.         The piston’s drive tip is damaged.

| 1.         Replace the controller.

2.         Use      undamaged     fasteners     of     the recommended type.

3.         Tighten screw connections.

4.         Replace the piston.

The fastener is not driven                in

sufficiently deeply

| 1.         The piston’s drive tip slips off the fastener.

2.         Low air pressure.

3.         Low     work     speed    and

output.

| 1.         Replace the piston.

2.         Correct the air pressure.

3.         Check that a suitable, undamaged cylinder

head spring is installed. Check whether the blow-off in the cylinder head is blocked.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JULA User Manuals

Related Manuals