SUNRISE MEDICAL Q700 M/F/R Power Wheelchair Instruction Manual
- June 9, 2024
- SUNRISE MEDICAL
Table of Contents
Q700 M/F/R Power Wheelchair
Powered Wheelchair Fauteuil roulant électrique Elektrische rolstoel
Quickie Q700 M/F/R Q700 M HD Q700-UP M Q700-UP F
000690770.02
Instructions for Use Manuel d’utilisation Gebruikershandleiding
Wheelchair Components
EN
We at SUNRISE MEDICAL have been awarded the ISO-13485 certificate, which affirms the quality of our products at every stage, from R & D to production. This products meet the requirements in accordance with EC regulations. Options or accessories shown are available at extra cost.
Description du fauteuil
FR
Nous, la société SUNRISE MEDICAL, sommes certifiés ISO-13485, ce qui garantit la qualité de nos produits à tous les stades, du développement jusqu’à la production. Ce produit est conforme aux exigences des réglementations de l’Union européenne. Les options ou accessoires illustrés sont disponibles en option.
Rolstoelonderdelen
NL
SUNRISE MEDICAL heeft het ISO 13485 certificaat toegekend gekregen, een bewijs van de kwaliteit van onze processen in elk stadium, vanaf het onderzoek en de ontwikkeling tot de productie. Dit product voldoet aan de vereisten van de regelgeving van de Europese Unie. Getoonde opties en accessoires zijn tegen betaling verkrijgbaar.
03
UK
2
52
FR
101
NL
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
If you have any queries about the use, maintenance or safety of your
wheelchair, please contact your local approved Sunrise Medical service agent.
If you do not know of an approved dealer in your area or have any other
questions please write or telephone: Sunrise Medical Thorns Road Brierley Hill
West Midlands DY5 2LD England Phone: 0845 605 66 88 Fax: 0845 605 66 89
www.SunriseMedical.co.uk
Dealer signature and stamp
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
Contents
1.0 User information…………………………………………………… 4 1.1 This user manual
……………………………………………………..4 1.2 For further information…………………………………………….4 1.3
Symbols used in this manual……………………………………..5
2.0 Safety …………………………………………………………………. 6 2.1 Symbols and labels used on the
product…………………….6 2.2 Safety: Temperature…………………………………………………6 2.3 Safety:
Moving parts ………………………………………………..7 2.4 Safety: Electromagnetic
radiation………………………………7 2.5 Safety: Choking hazard……………………………………………..8 2.6
Safety: Using a (vehicle mounted) wheelchair lift ………..8 2.7 Safety:
Trays…………………………………………………………….8 2.8 Safety: Lifting the
wheelchair…………………………………….8
3.0 Intended use of the wheelchair……………………………….. 8 3.1 Area of application:
The user…………………………………….8 3.2 Area of application: The user environment
……………….10
4.0 Setting up the wheelchair …………………………………….. 11 4.1 Seating
system……………………………………………………….11 4.2 Seat Depth ……………………………………………………………11 4.3
Seat height…………………………………………………………….11 4.4 Centre of
gravity…………………………………………………….11 4.5 Controller height and depth
……………………………………11 4.6 Control system programme …………………………………….11 4.7 Lap strap
/ seating positioning belt…………………………..12
5.0 Using the wheelchair …………………………………………… 13 5.1 Checking wheelchair before
use………………………………13 5.2 Making a transfer …………………………………………………..14 5.3 Driving
the wheelchair ……………………………………………14 5.4 Curves…………………………………………………………………..15 5.5
Braking & Emergency stop ………………………………………15 5.6 Driving on a
slope…………………………………………………..16 5.7 Obstacles & kerbs:………………………………………………….17 5.8
Pushing the wheelchair…………………………………………..18 5.9 (Powered) seating options
………………………………………19
6.0 Batteries, charging and range ………………………………… 20 6.1 Batteries
……………………………………………………………….20 6.2 Charging batteries: ………………………………………………..21 6.3
The range of your vehicle:……………………………………….22 6.4 Battery warranty:
…………………………………………………..22 6.5 Replacing batteries…………………………………………………23 6.6
Disconnecting batteries for air transport…………………..23
7.0 Transportation ……………………………………………………. 25 7.1 Transport of the wheelchair in
a car…………………………25 7.2 Using the Dahl Docking System ……………………………….27 7.3 The
wheelchair as a passenger seat …………………………32 7.4 Special transport requirements
……………………………….33 7.5 General transport warnings …………………………………….34
8.0 Maintenance & cleaning ………………………………………. 35 8.1 Maintenance
…………………………………………………………35 8.2 Tyre maintenance and pressures……………………………..37 8.3
Wheels & tyres maintenance…………………………………..40 8.4 Lighting
maintenance:…………………………………………….41 8.5 Cleaning and
disinfection………………………………………..41 8.6 Medium to long term storage:
………………………………..41
9.0 Disposal …………………………………………………………….. 42 10.0 Trouble shooting
……………………………………………….. 43 11.0 Technical specifications: Applicable norms /
standards 43 12.0 Warranty………………………………………………………….. 50 13.0 Nameplate
……………………………………………………….. 51
3
ENGLISH
ENGLISH
1.0 User information
Thank you for choosing a Sunrise Medical wheelchair. Sunrise Medical’s high-
quality mobility products are designed to enhance independence and make your
everyday life easier.
As a part of our ongoing product improvement initiative, Sunrise Medical
reserves the right to change specifications and design without notice.
However, any changes to information provided for existing users shall be
clearly communicated if they are safety critical.
Further, not all features and options offered are compatible with all
configurations of the wheelchair.
All dimensions are approximate and may be subject to change.
The intended lifetime of the wheelchair is 5 years. Please DO NOT use or fit
any 3rd party components to the wheelchair unless they are officially approved
by Sunrise Medical.
1.1 This user manual
This user manual will help you to use and maintain your wheelchair safely.
This entire user manual for this wheelchair consists of four booklets:
· The general wheelchair user manual (this booklet) · The user manual for the
seating system · The user manual for the controller · The user manual for the
battery charger
When necessary this general user manual refers to other manuals as shown in the table below:
& Seating system: & Controller: & Battery charger:
Refers to the user manual for the seating system. Refers to the user manual for the controller. Refers to the user manual for the battery charger.
Do not use your wheelchair until this entire manual and all relevant booklets
have been read and understood!
If one of the user manuals was not included with your wheelchair, please
contact your dealer immediately.
1.2 For further information
Please contact your local, authorized Sunrise Medical dealer if you have any
questions regarding the use, maintenance or safety of your wheelchair. In case
there is no authorized dealer in your area or you have any questions, contact
Sunrise Medical either in writing or by telephone. For information about
product safety notices and product recalls, go to www.SunriseMedical.co.uk
DC AB
E FG
If you are visually impaired, this document can be viewed
in PDF format at www.SunriseMedical.co.uk
or alternatively is available on request in large text.
4
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
1.3 Symbols used in this manual
DANGER! WARNING! CAUTION!
Potential risk of injury or serious injury or death Potential risk of injury Potential damage to equipment
As the manufacturer, SUNRISE MEDICAL, declares that this product conforms to the Medical Device Regulation (2017/745).
NOTE: General user advice. Not following these instructions may result in
physical injury, damage to the product or damage to the environment!
Notice to the user and/or patient: Any serious incident that has occurred in
relation to the device should be reported to the manufacturer and the
competent authority of the Member State in which the user and/or patient is
established.
B4Me special adaptations Sunrise Medical strongly recommends that in order to
ensure that your B4Me product operates, and performs as intended by the
manufacturer; all the user information supplied with your B4Me product is read
and understood, before the product is first used.
Sunrise Medical also recommends that the user information is not discarded
after reading it, but it is kept safely stored for future reference.
Medical Device Combinations It may be possible to combine this Medical device
with one or more other Medical Device or other product. Information on which
combinations are possible can be found at www.Sunrisemedical.co.uk. All
combinations listed have been validated to meet the General Safety and
Performance Requirements, Annex I Nr. 14.1 of the Medical Device Regulation
2017/745.
Guidance on the combination, such as mounting, can be found at
www.SunriseMedical.co.uk.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
5
ENGLISH
2.0 Safety
Follow the instructions carefully next to these warning symbols! Not paying
careful attention to these instructions could result in physical injury or
damage to the wheelchair or the environment. Wherever possible, safety
information is provided in the relevant chapter.
2.1 Symbols and labels used on the product
The signs, symbols and instructions affixed to the wheelchair comprise part of
the safety facilities. They must never be covered or removed. They must remain
present and clearly legible throughout the entire lifespan of the wheelchair.
Replace or repair all illegible or damaged signs, symbols and instructions
immediately. Please contact your dealer for assistance. Fig. 2.1. Warning – Do
Not Touch – HOT Fig. 2.2. Taxi fixation point Fig. 2.3. Warning Danger of
finger entrapment Fig. 2.4. Warning Ensure that the seat interface quick
release is screwed in
tight before using your wheelchair, especially on a slope Fig. 2.5. Warning
Do not drive your wheelchair on a slope with the backrest
reclined and/or the seating in standing mode Fig. 2.6. Warning Maximum user
weight for the wheelchair: 160 kg Fig. 2.7. Warning Maximum user weight for
the wheelchair: 205 kg Fig. 2.8. Freewheel mechanism: outward lever down =
freewheel Fig. 2.9. The serial number and information label, (example only).
Fig. 2.10. Location of Serial Number Label, (overleaf – Fig. 2.10.1 Mid wheel,
Fig. 2.10.2 Front Wheel, 2.10.3 Rear Wheel).
2.2 Safety: Temperature
WARNING! · Avoid physical contact with the wheelchair’s motors at all times.
Motors are
continuously in motion during use and can reach high temperatures. After use,
the motors will cool down slowly. Physical contact could cause burns. Allow
the motors after using at least 30 min. to cool down. · If you do not use the
wheelchair, ensure that it is not exposed to direct sunlight for lengthy
periods of time. Certain parts of the wheelchair, such as the seat, the back
and the armrests can become hot if they have been exposed to full sunlight for
too long. This may cause burns or allergic reactions to the skin. · The
surface of the upholstery on the chair (Armrest and/or Calf Pad) may become
hot or cold due to environmental conditions. This may cause burns, skin damage
or allergic reactions to the skin.
Fig. 2.1
Fig. 2.2
Fig. 2.3
Fig. 2.4
Fig. 2.5
Fig. 2.6
MAX
160 kg
R
Fig. 2.7
MAX
205 kg
Fig. 2.8
TYPE: Q700 M
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-03-09 203204229996547
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7M20100330 max
kg
160 kg 350 kg 6 km/h max 6° 60kg/290kg/60kg
TYPE: Q700 F
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-04-22 203204230017105
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7F20109639 max
kg
160 kg 385 kg 10 km/h max 6° 100kg/318kg
Fig. 2.9
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
2020-10-20
TYPE: Q700-UP M
POWER WHEELCHAIR ISO 7176-19:2008
203203729322630 FIN-Nr: 7UPM20960
max max max
max
kg
kg
kg
120 kg 350 kg 10 km/h max 6° 60kg/290kg/60kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
2021-09-27
TYPE: Q700 M HD
POWER WHEELCHAIR ISO 7176-19:2008
203213435071452 FIN-Nr: 7M2187621
max max max
max
kg
kg
kg
205 kg 395 kg 8 km/h max 6° 90kg/305kg/90kg
TYPE: Q700 R
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-04-22 203204330174565
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7R20104951 max
kg
160 kg 385 kg 10 km/h max 6° 240kg/190kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
2020-01-29
TYPE:
E-Rollstuhl
Q700-UP F
ISO 7176-19:2008
max max max
203200423282846 FIN-Nr: 7UPF201214 max
kg
kg
kg
120 kg 385 kg 10 km/h max 6° 100kg/318kg
6
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
2.3 Safety: Moving parts, (Fig.2.11)
DANGER! A wheelchair has moving and rotating parts. Contact with moving parts
may result in serious physical injury or damage to the wheelchair. Contact
with the moving parts of the wheelchair should be avoided. · Wheels (turning
and castor) · Powered tilt in space adjustment · Powered seat elevator option
· Powered recline adjustment · Swing-away bracket of the controller
2.4 Safety: Electromagnetic radiation
CAUTION! The standard version of your electric wheelchair has been tested on
the applicable requirements with respect to electromagnetic radiation (EMC
requirements) In spite of these tests: It cannot be excluded that
electromagnetic radiation may have an influence on the wheelchair. For
example: · mobile telephony · large-scale medical apparatus · other sources of
electromagnetic radiation · It cannot be excluded that the wheelchair may
interfere with
electromagnetic fields. For example: · shop doors · burglar alarm systems in
shops · garage door openers In the unlikely event that such problems do occur,
we request that you notify your dealer immediately.
DANGER! · When operating two-way radio, walkie-talkies, C.B., Amateur radio,
public mobile radio and other powerful transmitting devices the wheelchair
should be brought to a halt and turned off. · The operation of cordless,
mobile telephones and cell phones including hands-free devices is permitted
but if abnormal operation of the wheelchair is encountered then the chair must
be brought immediately to a halt and turned off.
Fig. 2.10.1
MWD/MWD HD
TYPE: Q700 M
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-03-09 203204229996547
max
ISO 7176-19:2008 max max
kg
FIN-Nr: 7M20100330 max
kg
160 kg 350 kg 6 km/h max 6° 60kg/290kg/60kg
Fig. 2.10.2 FWD
TYPE: Q700 F
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-04-22 203204230017105
max
ISO 7176-19:2008 max max
kg
FIN-Nr: 7F20109639 max
kg
160 kg 385 kg 10 km/h max 6° 100kg/318kg
Fig. 2.10.3 RWD
Fig. 2.11
TYPE: Q700 R
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-04-22 203204330174565
max
ISO 7176-19:2008 max max
kg
FIN-Nr: 7R20104951 max
kg
160 kg 385 kg 10 km/h max 6° 240kg/190kg
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
7
ENGLISH
2.5 Safety: Choking hazard
DANGER! This mobility aid uses small parts which under certain circumstances
may present a choking hazard to young children.
2.6 Safety: Using a (vehicle mounted) wheelchair lift Wheelchair lifts are
used in vans, buses and buildings to help you move from one level to another.
DANGER! · Ensure that the user and all carers fully understand the lift
manufacturer’s instructions for using the passenger lift. · Never exceed the
lift manufacturer’s recommended safe
working load and load distribution guidance. · Always turn off all power when
you are on the lift. If you fail
to do so, you may touch the joystick by accident and cause your chair to drive
off the platform. Be aware that a roll-stop at the end of the platform may not
prevent this. · Always position the user securely in the chair to help avoid
falls while on the lift. · Always ensure the chair is in drive mode when using
passenger lift (wheels locked not in freewheel mode).
2.7 Safety: Trays
Safety: Swing away tray:
DANGER! · The maximum weight allowed for the tray is 2.5kg. · Do not overload
the tray, this could cause the tray to break
or could cause the chair to become unstable. · Please make sure any items
placed on the tray are secure as
they could fall and cause injury. · Do not leave lit cigarettes or other heat
sources on the tray
as this could cause the tray to deform and mark – and, in extreme cases, lead
to fire. · Ensure that all extremities and clothing are clear when positioning
the tray for use.
2.8 Safety: Lifting the wheelchair
WARNING! · Do not lift this seating system by any parts that are
removable, doing so may result in damage to the seating system or injury to
the user.
3.0 Intended use of the wheelchair
General description The Q700 range is an ultimate modular power wheelchair. A
distinctive feature is the advanced suspension system that allows you to have
an excellent driving experience indoors as well as outdoors. Due to its
modular design, simplicity and wide range of adjustments, the Quickie Q700
series is a perfect choice for easy service, refurbishment and recycle
requirements.
The Q700 series fulfils individual preferences, needs or circumstances and is
available in the following configurations: · Midwheeldrive (MWD): Q700 M with
Sedeo Pro/Sedeo Pro
Advanced · Midwheeldrive (MWD): Q700 M HD with Sedeo Pro · Midwheeldrive
(MWD): Q700-UP M with Sedeo Pro
Advanced UP · Frontwheeldrive (FWD): Q700 F with Sedeo Pro/Sedeo Pro
Advanced · Frontwheeldrive (FWD): Q700-UP F with Sedeo Pro
Advanced UP · Rearwheeldrive (RWD): Q700 R with Sedeo PRO
To have optimum seating support and individual adjustments the Q700 series is
available in combination with · Sedeo Pro Advanced/Sedeo Pro Advanced UP
seating system
(refer to seating manual &) · Sedeo Pro seating system (refer to seating
manual &)
3.1 Area of application: The user
Power wheelchairs are exclusively for a user who is unable to walk or has
limited mobility, for their own personal use indoors and outdoors. Driving a
powered wheelchair requires cognitive, physical and visual skills. The user
must be able to estimate and correct the results of actions when operating the
wheelchair. The wheelchair cannot transport more than 1 person at a time. The
maximum weight limit (includes both the user and any weight of accessories
fitted to the wheelchair) is marked on the serial number label, which is
affixed to the chassis of the chair (Fig. 2.9). For restrictions on user
weight limit refer to seating manual &. The user must be informed of the
contents of this user manual before driving the wheelchair. In addition, the
user of the wheelchair must be given thorough instruction by a qualified
specialist before he or she participates in traffic. The first sessions in the
wheelchair should be practiced under supervision of a trainer/advisor.
When an Attendant Control Module is fitted, an assistant on behalf of the user
may operate the Power Wheelchair.
When a Dual Control Module is fitted the Power Wheelchair may be operated by
the user, or control may be switched to an assistant to operate on behalf of
the user.
8
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Indications
The varieties of fitting variants, as well as the modular design, mean that it
can be used by those who cannot walk or have limited mobility because of [R2]:
· Paralysis · Loss of extremity (leg amputation) · Extremity defect deformity
· Joint contractures/joint injuries · Illnesses such as heart and circulation
deficiencies, disturbance of
equilibrium or cachexia as well as for elderly people who still have strength
in the upper body.
The Quickie Q700-Up M/F wheelchair with standing function is specifically
developed for people who have lost to their ability to stand (e.g. paraplegia,
multiple sclerosis, cerebral palsy etc.). Standing is used for therapy and
prophylaxis of: · Osteoporosis: Without regular standing / vertical stress of
the
bones, bone density can steadily decrease. This leads to the risk of bone
fractures and other complications. · Decubitus prophylaxis: Whilst standing
the pressure on the ischial tuberosity is reduced to a minimum. · Skeletal
misalignments / back pain: Whilst seated the spinal column is naturally
elongated (kyphosis/hunchback). Standing facilitates a natural spinal position
and therefore better upper body stability. This prevents the risk of a
scoliosis. · Muscular atrophy: Without regular leg movement, the risk of
muscle shortening increases (muscular atrophy) and consequently contractures
may develop. Regular, self-standing training helps as movement therapy,
thereby avoiding contractures and preventing possible associated pains and
expensive operations. · Tonus regulation of spasticity: Frequent standing
helps to reduce spasticity and facilitates seat movement and positioning in
the wheelchair or bed. This supports a peaceful sleep. · Deeper respiration:
Straightening the upper body through standing decreases the pressure of the
abdominal cavity on the lungs. This improves and deepens respiration,
facilitates breathing and can also help reduce the risk of pneumonia. ·
Gastrointestinal complications: As with breathing, standing also reduces the
pressure on the digestive system. This facilitates digestion (intestinal
peristalsis) and helps with the improvement of bowl and bladder functions.
Contraindications
The wheelchair shall not be used in case of: · Perception disorder · Imbalance
· Seating disability
Basic Components (Fig.3.1). 1. Headrest 2. Joystick 3. Arm Rest 4. Seat Cushion 5. Leg Rest 6. Front Castor
7. Drive Wheel 8. Rear Castor 9. Motors
10. Battery Box 11. Back Upholstery
Fig. 3.1 11
10 9 8
7
11
10 9
8
7
11
10 9
1 2 3
4 5
6 1
2 3 4 5
6 1
2 3
4 5
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
7
6
9
ENGLISH
WARNING! · If you are under the influence of medicines that can have an
effect on your ability to drive, you are not permitted to drive a wheelchair.
· Adequate vision is required in order to safely operate a wheelchair in the
user situation concerned. · Not more than one person at a time can be seated
in the wheelchair. · Do not allow children to ride in the wheelchair
unsupervised.
CAUTION! · The user of the wheelchair is at all times completely
responsible for complying with the applicable local safety regulations and
guidelines.
Attendants When an Attendant Control Module is fitted, the Power Wheelchair
may be operated by an assistant on behalf of the user.
When a Dual Control Module is fitted the Power Wheelchair may be operated by
the user, or control may be switched to an assistant to operate on behalf of
the user.
WARNING! · Make sure you heed all warnings and follow all instructions in
each section of this manual. Warnings that apply to the user also apply to
you. · Do not stand or sit on any portion of this seating system. · You need
to work with the user, and the user’s doctor, nurse or therapist, to develop
safe methods best suited to your abilities and those of the user. · Check to
make sure push handle grips will not rotate or slip off. · Make sure you
always have comfortable access to the attendant controls while the chair is
moving and make sure that the controller is fixed securely to the chair. · Set
the speed of the attendant control to a speed that you can comfortably follow.
· Always turn off the power to the controller when leaving the user in the
chair.
3.2 Area of application: The user environment
This wheelchair has been designed to accommodate both indoor and outdoor use
(EN12184 (2014) Class B). When driving the wheelchair outdoors, drive only on
paved roads, pavements, footpaths and bicycle paths. The speed must be adapted
to suit the environment.
WARNING! · Drive carefully on slippery roads resulting from rain, ice or
snow! · You are required to turn on the lights in case of limited
visibility. · When driving at higher speeds you must be extra careful.
Select a lower maximum speed indoors, on the pavement and in pedestrian areas.
· Do not drive off high obstacles. · Do not attach a weight to the wheelchair
without the approval of a qualified specialist. This may negatively affect the
stability of the product.
CAUTION! · Prevent the wheelchair from coming into contact with sea
water: sea water is caustic and may damage the wheelchair. · Prevent the
wheelchair from coming into contact with sand:
sand can permeate into the moving parts of the wheelchair, causing extensive
wear on these parts. · Do not use the wheelchair if temperatures are below:
-25°C or above +50°C. · Do not open doors using the leg rests. · Do not push
and/or tow any objects with the wheelchair. · Do not drive through puddles of
water.
Fig. 3.2
10
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
4.0 Setting up the wheelchair
Sunrise Medical wheelchairs can be adjusted according to specific needs of the
user. In this, we make a distinction between wheelchair settings and
wheelchair seating adjustment options. Settings are carried out once, the
first time the wheelchair is going to be used. They must be executed by
qualified specialist, unless explicitly stated otherwise. Seating adjustment
options can be carried out by the user. These adjustment options do not
require the use of tools.
4.1 Seating system
The extensive settings with respect to the seating system allow for optimum
support of the body (& Seating system). The following setting options are
possible: 1. Seat depth and seat width 2. Backrest angle 3. Armrest
height/width 4. Lower leg length 5. Angle of the footplate 6. Legrest angle
4.2 Seat Depth
CAUTION! For optimum comfort and driving experience of your FWD powerchair,
recommended seat depth relationship to user weight is: 75kg user weight up to
a seat depth of 44cm 90kg user weight up to a seat depth of 50cm, 160kg user
weight up to a seat depth of 56cm
Where chair configuration allows, a recommended backrest angle of 95° and a
seat tilt of 5° will further improve the driving experience.
4.3 Seat height
Depending on the specific circumstances of the user of the wheelchair the seat
height can be set. Every optional seat height lies within the Rated slope as
described in EN12184 (2014) Class B. Lowering the seat height has a positive
influence on the (dynamic) stability.
4.4 Centre of gravity
DANGER! Adjusting the centre of gravity on a powered wheelchair is both
physically demanding and safety critical. Sunrise Medical recommends that this
adjustment is only performed by a service agent/dealer approved by Sunrise
Medical.
4.5 Controller height and depth (& Seating system).
4.6 Control system programme This wheelchair is equipped with a control system
that can be programmed by adjusting settings within the system. This is a
specialized job that needs training and can only be adjusted with professional
software. The end user is not allowed to adjust these settings.
DANGER! The incorrect setting of the parameters for the control system may
result in very dangerous situations. Settings must be made by qualified
specialists.
WARNING! Increasing the seat height has a negative effect on dynamic stability.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
11
ENGLISH
4.7 Lap strap / seating positioning belt
DANGER! / WARNING!
· This product is only to be used to position a single person in a wheelchair.
· Lap straps are not suitable for transit purposes, approved occupant
restraint systems must be used.
· Failure to heed these warnings may result in severe injury or death. ·
Ensure that the carer or attendant is trained in the correct
operation of the belts. · Untrained carers or attendants may lead to delays,
if an emergency
situation occurs.
Mounting a lapstrap / seating positioning belt
1. Attach (A) to the seating frame using a screw on the left and on the right. (Fig 4.2)
Positioning an person with a lapstrap
· Adjust the lap strap to suit, leaving no more than a hand’s width
gap for comfort and safety (Fig 4.3).
· The hand clearance should be with the lap strap under normal
tension and not allow large gaps or loops.
· Generally, the lap strap should be fixed so that the straps sit at an
angle of approximately 45° (Fig. 4.4), and when correctly adjusted
should not allow user to slip down in the seat.
· Place the strap loosely across the seat with the opening end of the
A
buckle facing to the right for a left-handed person and to the left for
a right-handed person. Pass the other ends of the strap through the
gap between the backrest posts and the backrest.
Fig. 4.1 Fig. 4.2
DANGER! / WARNING!
· Always make sure that the lap strap is correctly secured and adjusted prior
to use.
· Too loose a strap could cause the user to slip down and cause serious
injury.
· Check lap strap and securing components at regular intervals for any signs
of fray or damage. Replace if necessary.
· When servicing, check for correct operation of the release buckle and for
any signs of wear on the material or plastic brackets.
· Regular Checks/Activities: · As with all positioning components, there is a
need for corrective
adjustments as the person changes their seating position over time. · Check
the belts regularly for correct fitting, to ensure the safety and
comfort of the user.
1
Fig. 4.3
Fig. 4.4
45°
12
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
5.0 Using the wheelchair
DANGER! · Be aware that you may need to adjust the controller settings
of your system. · Consult your authorised dealer to adjust the control
settings
immediately if you notice any change in your ability to:
1. Control the joystick 2. Hold your torso erect 3. Avoid running into
objects.
5.1 Checking wheelchair before use
Perform the following daily check routine before driving:
CAUTION! Checking wheels & tyres · Are the tyres sufficiently inflated
(Chapter 8.2).
Checking batteries · Before using your vehicle for the very first time, please
charge
your batteries for a period of 24 hours. · Are the batteries sufficiently
charged? The green lights on the
battery indicator must be on. & Controller
Checking lights and indicators · Ensure that the lights and indicators are
functioning correctly
and lens are clean before going outdoors at night. & Controller
Checking remote · With the control system switched off, check that the
joystick
is not bent or damaged and that it returns to the centre when you push and
release it.
Checking free wheel lever · Ensure that the free wheel lever has been set to
`drive’.
(Chapter 5.8).
Checking seating · Ensure that all the cushions are in place. · Make sure that
the backrest is correctly fitted and adjusted. · Visually inspect the
wheelchair to make sure the leg rests,
armrests etc. are correctly positioned and attached to the wheelchair and all
fasteners are sufficiently tightened. · Ensure that the seat interface knobs
are tight and secure.
Checking clothing on potential entrapment · When operating the wheelchair,
ensure that your clothing
does not hamper the wheelchair (i.e. too long). Before use, always check if
your clothing or accessories do not come into contact with the wheels or and
other moving and/or rotating parts in which they could become entangled.
Checking weather conditions · In winter, batteries have a reduced capacity.
During a period
of light frost, the capacity is roughly 75% of the normal capacity. At
temperatures below -5°C this will be roughly 50%. This will reduce your range
of action.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
13
ENGLISH
5.2 Making a transfer Sunrise Medical recommend that you consult your
healthcare professional for assistance in developing your personal front or
side transfer technique to best suit your needs and avoid any personal injury.
Preparing for a forward transfer:
DANGER! It is dangerous to transfer on your own. It requires good balance and
agility. Be aware that there is a point during every transfer when the seating
system seat is not below you.
For further instructions and warnings about making a transfer, please refer to
& Seating system.
5.3 Driving the wheelchair
WARNING · The user of the wheelchair is at all times completely
responsible for complying with the applicable local safety regulations and
guidelines.
Powered wheelchairs are driven by means of a controller. There is a separate
user manual for the controller and this was included with this wheelchair (&
Controller). 1. Switch on the controller. 2. Set the maximum speed limit. 3.
Move the joystick in the direction in which you would like
to go. 4. Moving the joystick even further forwards will cause the
wheelchair to drive faster.
Rear view mirror
WARNING · To avoid injury to people around you please be aware that
the mirror protrudes outside the space envelope of the chair and could cause
injury to someone when driving past. · The mirror must be used on models at
speeds over 6 kph on roads according to local law. · Always make sure that
when using the mirror that it is clean and unbroken so that it does not impair
your visibility.
14
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Road use Please show the utmost consideration for the other traffic on the
road.
DANGER! · Remember that the last thing a car or lorry driver expects to
see is a wheelchair backing off the kerb into the road. · If in any doubt, do
not risk crossing the road until you are
certain that it is safe. · Always cross the road as quickly as possible, there
may be
other traffic. · Do not drive over anything that could cause punctures in
the tyres. · Ensure that there are no objects in your path that could
possibly become lodged in your chair mechanism or in the spokes of the rear
wheels. This could cause the chair to come to a sudden stop. · Riding over
drains or grids could cause the wheelchair castors or wheels to become lodged,
causing the chair to come to a sudden stop.
Adverse conditions: Please be aware that when driving your wheelchair in
adverse conditions, e.g. on wet grass, mud, ice, snow or other slippery
surfaces, you may experience a reduction in the grip and traction of your
wheelchair.
DANGER! · We recommend you take extra precautions in these
conditions, particularly on hills and slopes; your wheelchair could become
unstable or skid causing possible injury. · When you are using a Powered
Wheelchair take extra care with loose or long items of clothing. Moving parts,
such as wheels, can be potentially dangerous or even fatal if clothing becomes
entangled.
NOTE : Extreme variances in temperature may trigger the self protect mechanism
in the control system. If this occurs the control system will temporarily shut
down to prevent damage to the electronics or the wheelchair.
5.5 Braking & Emergency stop
There are three ways to stop your wheelchair: · Simplest and safest way to
stop the wheelchair is to release
the joystick. This will bring the chair to a halt in a controlled manner. ·
Pulling back the joystick will break the chair abruptly with a fast stop. ·
Switching the control system off whilst the chair is in motion will also bring
the chair to a halt.
WARNING! · Switching the control system off is only to be used in an
emergency situation as the stopping action is very abrupt. · Never try to stop
or slow this seating system with the wheel
locks (if applicable). Wheel locks are designed to pre-vent the system from
moving when stopped. They are not brakes.
5.4 Curves
DANGER! Full speed turns should not be attempted. If you need to turn sharply
you must reduce your speed with the joystick or speed setting. This is
particularly important when travelling across or down a slope. Disregarding
this advice could lead to your wheelchair tipping over.
WARNING! Use indicators when changing direction.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
15
ENGLISH
5.6 Driving on a slope
Your wheelchair has been designed and tested to allow its use on slopes or
gradients of up to: Q700 M: 6° (10.5%) in standard configuration. Q700 M HD:
6° (10.5%) in standard configuration. Q700 F: 6° (10.5%) in standard
configuration. Q700 R: 6° (10.5%) in standard configuration. Q700-UP M: 6°
(10.5%) in standard configuration. Q700-UP F: 6° (10.5%) in standard
configuration.
However, you have the option of adjusting your position with the seat
elevator, tilt in space, powered recline or powered centre mount leg rest or a
combination of these options.
DANGER! · Elevating, tilting and leg rest adjustments can affect the
wheelchair centre of gravity. Under certain conditions this might cause
instability that could lead to unintentional tipping. It may be necessary to
carry out a risk assessment if the wheelchair is adjusted to extremes. ·
Stopping distances on slopes can be significantly longer than on level ground.
DANGER! · In certain circumstances your wheelchair could become
unstable. · Before attempting to climb or descend a slope or a kerb,
caution should be taken when using weight shift options (e.g. powered ,
recline or standing), of the seat and/or your body for a counter balance
weight. · To improve stability lean forward when driving uphill, with the seat
and back in an upright position. · Alternatively sit in an upright position
when travelling in a forward, downhill direction or and/or recline the seat
backwards. · We strongly recommend that you return the seat and back to their
home positions before attempting to climb or descend a slope. Failure to do
this may cause the wheelchair to become unstable. · If you are in any doubt
about the capabilities of your wheelchair on a slope then do not attempt to
drive up or down the slope/kerb; try to find an alternative route.
Gradients: ascents:
WARNING! · When going uphill, keep the chair moving. · Steer by carefully
moving the joystick forwards making
slight Left and Right adjustments as you go. · If you have stopped on a hill,
you should start slowly. · If necessary lean forward.
Gradients: descents: On descents, it is important not to let the wheelchair
accelerate beyond its normal level of ground speed.
DANGER! · Proceed slowly down steep descents, (below the speed of
5kph) and stop if you fell anxious. · If the chair picks up speed, centre the
joystick to its home
position to allow it to slow, or to stop. · Restart slowly and do not allow
the speed to increase above
what you are comfortable with.
NOTE: · The controller has the benefit of a logic system that will
help compensate when driving along a camber or up a hill. This is an added
safety feature on your wheelchair. In addition of course, you may control the
wheelchair speed by using the speed control.
16
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
5.7 Obstacles & kerbs:
DANGER!
· Never descend a kerb backwards. · Do not attempt to climb or descend a
series of steps or use
on escalators. It is unsafe to do so and could cause personal injury or damage
the chair. This wheelchair has only been designed to climb a single step or
kerb. · We recommend that users with upper trunk instability wear restraint
systems to keep the upright body position during descending or ascending
ramps, kerbs or obstacles.
Kerb climbing: Always approach a kerb at 90° (Fig. 5.1).
· Approach the kerb or step, head on at a 90° angle. · Drive forwards slowly
and steadily. · Stop the chair as soon as the castor wheels touch the kerb. ·
Apply sufficient power to the motors to lift the front of
the chair up onto the kerb or step and then apply slightly more power until
the drive wheels climb the kerb or step smoothly. · As far as possible, keep
the joystick in the straight forward position.
The maximum obstacle or kerb climbing height is:
Q700 M:
100 mm. (Max. user weight 100 kg)
Q700 M HD: Q700 F:
75 mm. 70 mm.
Q700 R:
80 mm.
Q700 R + kerbclimber: 100 mm.
Q700-UP M:
80 mm.
Q700-UP F:
75 mm.
The approach speed and process can vary depending on your wheelchair drive type and castor wheel choice.
Dismounting the kerb. DANGER!
Move the chair slowly and carefully in a forward direction until both front
wheels are on the edge of the kerb, again in a 90° position to the kerb. Drive
as slowly as possible off the kerb with the drive wheels. Don’t stop the chair
during decent of the kerb. You will feel more secure if you can lean
backwards, but if you can’t, don’t worry, the wheelchair is stable. As long as
you stay within its limitation, you will be quite safe. All powered seating
options need to be in home position. Your powered leg rests may need to be
adjusted to give enough clearance to mount or dismount the kerb. We recommend
to use the lap strap to feel more secure during declining the kerb. For extra
protection we recommend to fit every chair with the leg rests.
Fig. 5.1
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
17
ENGLISH
5.8 Pushing the wheelchair
The wheelchair can be moved by pushing. In order to do so, the motors must be
disengaged using a freewheel lever. This feature was developed for the
attendants of wheelchair users and also functions as an emergency freewheel
lever. The freewheel lever has 2 positions
1. For driving the wheelchair. (Fig. 5.2).
Drive’ position: Turn the lever so that the lever at the drive wheel side is pointing upwards. 2\. For disengaging the motors. (Fig. 5.3 – Fig.5.4).
Push’ position: Turn the lever so that the lever at the drive wheel side is
pointing downwards.
DANGER! · The free wheel lever should only be operated by the attendant and
never by the user. · A user may never be left unattended while the wheelchair
is in
push’. · Never set the lever to the
push’ position on a slope! When the
freewheel lever is set to push’, the automatic parking brake is deactivated. This makes it possible for the wheelchair to roll down the slope. · The automatic parking brake only works is the lever is set to
drive’ position. ·
When the wheelchair is no longer being pushed, the freewheel lever should be
set to `drive’ immediately. · To manually push the system you must release the
motor brakes. · Do not engage or disengage motor brakes unless power to the
system is off. · Make sure you have full control over the system when you
release the motor brakes. When you do so the system will not have brakes. ·
Make sure the system is on level ground before you release the motor brakes. ·
Propel this system by the push handles only. They provide secure points for
you to hold the rear of the system to prevent a fall or tip-over. · Check to
make sure push handle grips will not rotate or slip off.
Fig. 5.2 Fig. 5.3
Fig. 5.4
18
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
5.9 (Powered) seating options
The wheelchair can be equipped by the following mechanical and/or powered
options to adjust your seating position. These options can be operated by the
user without the use of tools. Powered adjustable seating options (Fig. 5.5 –
Fig. 5.7). How to operate these powered seating options can be found in &
Controller + & Seating:
1. Powered tilt function 2. Powered seat elevator 3. Powered backrest recline
4. Powered elevating leg rests
The wheelchair may be equipped with a feature that allows the powerchair to be
driven up to 4.5kph/3mph when the seat is elevated, this feature is called
C-Me. For guidance with user weight limits and recommended chair configuration
when using C-Me, please refer to your Sunrise Medical authorized dealer. Note:
User weight is restricted to a maximum of 136kg in combination with the C-Me
option.
DANGER!
· Use of the powered adjustable seating options may influence the stability of
the wheelchair.
· Only use the powered adjustable seating options when the wheelchair is on a
flat surface! Do Not attempt to operate any power seating option while
positioned on an incline.
· Please stay clear of any powered actuator while the component is in motion.
Sunrise power mechanisms move over large ranges of travel. Users should be
aware of their surroundings while components are in motion.
· While driving this seating system in the reclined, elevated, or tilted
position use caution.
· Do Not attempt to operate any power seating option while this seating system
is in motion.
· Do not attempt to operate the lift or tilt power seating options around
children. · Through programming it is possible to reverse the direction of all
powered
seating functions, ensure you know which direction your seat is going to move
before operating. · Please be aware that the lift/tilt modules present a trap
hazard. Make sure that during operation the lift/tilt modules are free from
all clothing, hands, feet and other extremities, to prevent injury. · Do not
drive on ramps or slopes with the seating in the elevated position. Before
attempting to climb or descend a slope, return the wheelchair to a standard
seated drive position, with the backrest upright. · This power system is
designed to automatically reduce the maximum driving speed to a creep and/or
C-Me mode when certain power seating limits are reached. Depending on the
configuration of the chair there might be multiple creep and/or C-Me speeds. ·
Before operating your chair in creep and/or C-Me mode, read all warnings and
guidelines related to this feature. They will help in understanding how to
reduce the risk of a fall or tip-over and how to identify environmental
conditions that could affect your safety when driving while the chair is in
creep and/or C-Me speed.
1. When driving indoors or outdoors, in creep mode, it should only be used on
flat, level, and hardscape surfaces.
2. Driving in creep mode should never be attempted on uneven terrain like:
gravel, grass, bumpy surfaces, uneven pavement, or hills.
3. NEVER raise the seat when the chair is being operated in the proximity of
any of the terrain types listed above, or on any uneven surface.
1000 mm Fig. 5.5
Fig. 5.6
Fig. 5.7
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
19
ENGLISH
6.0 Batteries, charging and range
6.1 Batteries
Batteries are the power source for almost all of the modern mobility products
available today. The design of batteries used in mobility products is
significantly different to the batteries used to start a car for example. Car
batteries are designed to release a large amount of power over a short period
of time, whilst mobility batteries (commonly called deep cycle batteries)
release their power evenly, over a long period of time. Therefore, due to the
lower production volumes and increased technological requirements, mobility
batteries are typically more expensive. Commonly two 12 volt batteries are
used together in a mobility product, giving a total voltage of 24 volts. The
size of the battery (e.g. its available power) is expressed in amps per hour
e.g. 70amp/hr. The higher the number, the bigger the battery size, weight and,
potentially, the greater the distance you can travel. Sunrise Medical only fit
as standard maintenance free batteries into these types of wheelchairs. This
type of battery uses a method of carrying the electrolyte commonly referred to
as `gel’, that is held within the battery case. As the name implies, no
maintenance is required other than regular charging. You can safely transport
this type of battery without fear of acid spilling. Furthermore, they are
approved for transportation on aircraft, trains and ships.
CAUTION!
· Do not fit car batteries to the wheelchair. Fit only deep cycle, maintenance
free mobility batteries.
· When the batteries are worn out, take them to the local authority disposal
point.
· Do not expose any part of the battery to direct heat (i.e. naked flame, gas
fire).
· Be extra cautious to reduce the risk of dropping a metal tool onto the
battery. It could spark or short circuit the battery or other electrical parts
that may cause an explosion. Also take off all personal metal effects and
dangling objects when working on the battery.
· Return the batteries back to Sunrise Medical or directly to the battery
manufacturer for recycling, when they no longer hold charge.
· The battery terminals need to be checked regularly for signs of corrosion.
If any corrosion is apparent, then clean the terminals completely and re-
grease the terminal using Vaseline petroleum jelly, not ordinary grease.
Ensure that the terminal nut and bolt, cable clip and exposed cable are
completely covered with jelly.
DANGER!
· Do not expose any part of the battery to direct heat (i.e. naked flame, gas
fire).
· Be extra cautious to reduce the risk of dropping a metal tool onto the
battery. It could spark or short circuit the battery or other electrical parts
that may cause an explosion. Also take off all personal metal effects and
dangling objects when working on the battery.
100A RED
Battery Connector RED
YELLOW
100A Battery Connector 15A
BLACK
BLACK
Auxillary Power
Fig. 6.1
DANGER! · Do not, under any circumstances, tamper with the batteries.
If in any doubt contact your local Sunrise Medical authorised dealer. · Avoid
contact with acid on damaged sealed type batteries or wet batteries. · Battery
acid can cause burns to the skin as well as damage to floors, furniture and
your wheelchair. · If battery acid comes into contact with the skin or
clothing, wash immediately with soap and water. · If battery acid comes into
contact with the eye, immediately flood the eye with running cold water for at
least 10 minutes and seek medical attention immediately. · Acid spills can be
neutralised with baking soda and water. · Take care to keep batteries upright
at all times, especially when transporting your wheelchair.
Safety cut-outs In the event of a short circuit there are several safety
systems built into your wheelchair to safeguard your electrical circuits,
(Fig. 6.1). 1. Fusible 100A links are connected into the battery harnesses
to protect the batteries and wiring.
2. 15A auxiliary power circuit fuses for auxiliary modules and seating power
supply.
To replace them contact your Sunrise Medical authorised dealer, who will also
diagnose the original fault.
20
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
6.2 Charging batteries:
& Battery charger: Please read the owner’s manual with the charger supplied
carefully. The general procedures and effects for the interference with the
chair and the batteries remain valid.
Battery care plan
Below is set out a battery care plan for maintenance free batteries. This has
been agreed between Sunrise Medical and the battery manufacturers, to enable
you to get the best out of your batteries. If a different care plan is
followed, this may result in lower than expected performance from your
mobility vehicle.
· Only use an approved Sunrise Medical charger compatible with the vehicle to
be charged.
· Charge your batteries every night, regardless of the amount of use your
mobility device has had during the day.
· Do not interrupt the charging cycle. · If your mobility device is not
required for use, it should
remain connected to the charger until required. This will not damage your
batteries, as long as the mains socket/plug is left switched on. Turning the
mains socket/plug off, but leaving the mains cable plugged in will eventually
deplete your battery charge. · If you leave your vehicle for an extended
period (more than 15 days) charge the batteries fully and then disconnect the
main battery lead. · Failure to allow for recharge will damage the batteries
and can lead to shortened distances and premature failure. · Do not top up the
charge of your batteries during the day. Wait until the evening for a full
overnight charge. · As a general rule, maintenance free batteries take longer
to fully charge than “wet” lead acid batteries. · The battery terminals need
to be checked regularly for signs of corrosion. If any corrosion is apparent,
then clean the terminals completely and re-grease the terminal using Vaseline
petroleum jelly, not ordinary grease. Ensure that the terminal nut and bolt,
cable clip and exposed cable are completely covered with jelly. · Following
all the points above should result in a healthier battery, greater range for
the vehicle user and a longer life for your batteries.
Connecting the battery charger
Procedure for connecting the charger and charging · Switch off the wheelchair
controller. & Controller: · Connect the battery charger round output plug to
the
charging socket on the front of the joystick module. & Controller: · Connect
the charger to the mains supply by means of the mains plug and switch on.
For more information about the charger operation, consult the instructions
provided with the charger. & BATTERY CHARGER. Depending on how depleted the
batteries are, it may take up to 12 hours to fully charge the batteries again.
DANGER!
· Make sure the cord is located so that it will not be stepped on, tripped
over or otherwise subjected to damage or stress.
· Do not rest a battery on top of the charger. · Do not stand the charger on a
carpet or other soft surface.
Always place it on a hard flat surface. · Do not operate the charger if it has
received a sharp blow,
been dropped or otherwise damaged in any way. Take it to a qualified
technician. · Never place the charger directly above the battery being
charged; gases from the battery will corrode and damage the charger. · Never
charge a frozen battery. A fully charged battery will rarely freeze but the
electrolyte of a discharged battery can freeze at -9° Centigrade. Any battery
that is suspected of being frozen should be thawed completely before charging.
· Never sit with the charger on your lap when charging your batteries · The
charger casing will get hot during its normal operation. · Do not disassemble
charger; only have it repaired by the manufacturers. Incorrect re-assembly may
result in a risk of electric shock or fire. · To reduce the risk of an
electric shock, unplug the charger from the outlet before attempting any
maintenance or cleaning. Turning off the controls will not reduce the risk. ·
Never smoke or allow a spark or flame in the vicinity of battery or charger. ·
You should not charge your batteries in outdoor conditions. · It is advised to
use a smoke detector in the charging area.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
21
ENGLISH
Battery Charger
The external charger has been designed to charge two 12V Gel type batteries
connected in series (= 24 V).
The chargers have features which prevent hazards or accidents occurring as a
result of connecting batteries the wrong way round, overheating caused by
fault conditions or attempting to charge wrong voltage batteries. The majority
of charger sizes are electrically double insulated and no earth connection is
required. Some larger sizes may be electrically earthed and this will be
clearly stated on the label.
If your charger has been specified for use in Continental Europe it will
contain a European two pin plug which does not have a fuse. In this case the
fuse is located in the fascia panel of the charger.
Country specific information: UK
The 3 pin UK mains input plug contains a replaceable fuse. The rating of this
fuse is shown on the charger label.
DANGER! · As with all mains powered electrical equipment, always
replace blown fuses with the same type and size of fuse as specified. ·
Fitting of different fuses can result in an increased fire risk, damage to the
charger or failure of the charger to operate properly.
6.3 The range of your vehicle:
Please refer to the specification tables at the back of this manual for Energy
Consumption, (Maximum Range), information.
Most manufacturers of mobility products state the range of their vehicles
either in the sales literature or within the Owner’s Manual. The range stated
sometimes differs from manufacturer to manufacturer even though the battery
size is the same. Sunrise Medical measure the range of their vehicles in a
consistent and uniform manner, but variances still occur due to motor
efficiencies and overall product load weight.
The range figures are calculated to I.S.O. Standard 7176. Part 4: Wheelchair
Energy Consumption Theoretical Range.
This test is carried out in controlled conditions with new, fully charged
batteries, on a level test surface and a user weight of 100 kg. The range
figures stated should be seen as a theoretical maximum and could be reduced if
any single, or combination, of the following circumstances occur: · User
weight heavier than 100 kg. · Batteries whose age and condition are less than
perfect. · The terrain is difficult e.g. very hilly, sloping, muddy ground,
gravel, grass, snow and ice. · The vehicle climbs kerbs regularly. · The
ambient temperature is very hot or very cold. · Incorrect tyre pressures in
one or more tyres. · Lots of start/stop driving. · Also thick pile carpets
within the home can affect range. · Use of additional power consumption
options (e.g. light,
actuators, etc.)
The battery sizes available on each Sunrise Medical product should give
sufficient range to cope with the majority of customer’s lifestyles.
6.4 Battery warranty:
Battery warranties are subject to periods set by the manufacturers. However,
most of these warranties are subject to a wear and tear clause, and if you
genuinely wear out your batteries in 6 months, it will not be possible to
obtain a replacement under warranty.
22
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
6.5 Replacing batteries The wheelchair uses two 12V non-spillable `dry’ gel
batteries in series, these batteries are fully sealed and require no
maintenance. Spill-proof sealed batteries, such as “gelled electrolyte,”
should be installed on powered wheelchairs when used in a motor vehicle.
Replacing and servicing batteries is to be done by qualified specialist.
In case of malfunctioning batteries, contact your local dealer.
DANGER! · Do not attempt to replace or service batteries without the
supervision of trained and qualified personnel.
Fig. 6.2 Fig. 6.3
6.6 Disconnecting batteries for air transport.
The batteries are contained within the drive unit located under the battery
shroud.
To disconnect the batteries: · Release the two handle screws under the front
of the seat frame,
that connect the seat frame with the seat module interface, (Fig.6.2). · Flip
the seat frame backwards (Fig.6.3). · Ensure the seat is secured with the seat
stay in place, before letting go, (Fig.6.4.1 – A). You must make sure that the
red seat stay is fully latched onto the pin. · Lift off the battery box lid,
(Fig. 6.4.1 – B). · Disconnect the 2 pin Anderson connectors from each battery
(Fig.6.5).
Fig. 6.4.1
To reconnect the batteries reverse the above procedure.
B
WARNING:
Removing the batteries can lead to a change of the center point of gravity.
The result may be that the chair flips backwards without the weight of the
batteries. Sunrise advises to: · Putting an obstacle behind the chair to
secure the situation.
This can be a chest, or a chair, or etc. · Try to lift the battery slightly
first to check the effect of taking
out the weight.
Fig. 6.4.2
B
Fig. 6.5
MWD
A
FWD
A
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
23
ENGLISH
To disconnect the batteries on Front and Rear-wheel drive: · Release the two
handle screws under the mid of the seat
frame, that connect the seat frame with the seat module interface (step 1) and
release the lever (step 2) (Fig.6.6). · Flip the seat frame backwards
(Fig.6.7). · Ensure the seat is secured with the seat stay in place, before
letting go, (Fig.6.7 Front). · Once secured (Fig.6.4.2 – A), lift off the
battery box lid, (Fig. 6.4.2 – B). You must make sure that the red seat stay
is fully latched onto the pin. · Disconnect the 2 pin Anderson connectors from
each battery (Fig.6.5).
To reconnect the batteries reverse the above procedure.
Fig. 6.6
WARNING:
Removing the batteries can lead to a change of the center point of gravity.
The result may be that the chair flips backwards without the weight of the
batteries. Sunrise advises to: · Putting an obstacle behind the chair to
secure the situation.
This can be a chest, or a chair, or etc. · Try to lift the battery slightly
first to check the effect of taking
out the weight.
Fig. 6.7
FWD
2 1
FWD
24
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
40° 60°
ENGLISH
7.0 Transportation
7.1 Transport of the wheelchair in a car
Getting in and out of the vehicle
DANGER! · Confirm that the vehicle is suitably equipped to transport a
passenger in a wheelchair, and ensure the method of access/ egress is suitable
for your wheelchair type. The vehicle should have the floor strength to take
the combined weight of the occupant, the wheelchair and accessories. · Use a
ramp (or lifting device) suitable for the entire weight of the wheelchair
(including user) for entering the vehicle. · The wheelchair should be secured
in a forward facing direction. This wheelchair is approved for use in cars and
meets the requirements for forward facing transport and head on collisions.
The wheelchair has not been tested for other positions in a vehicle (Fig.
7.1).
CAUTION! · Sufficient space should be available around the wheelchair
to enable clear access to attach, tighten and release the wheelchair and
occupant tie down restraints and safety belts. · Ease of access to, and
manoeuvrability in, motor vehicles can be significantly affected by wheelchair
size and turning radius; smaller wheelchairs and/ or wheelchairs with a
shorter turning radius will generally provide greater ease of vehicle access
and manoeuvrability to a forward-facing position.
Securing the wheelchair with a strap restraint system
This wheelchair has been successfully crash tested in accordance to: ISO
7176-19:2008, using a representing restraint system. · Use 6 straps if the
4-point system is not rated to the weight
of the wheelchair (2 at the front and 4 at the back) that conforms to ISO
10542-1 (international). Standard straps are only tested to 85kg. · It is
recommended to use with a 4-point strap restraint system rated for the total
weight of the wheelchair including any options (Heavy Duty System) – 2 at the
front, 2 at the back (Fig.7.2 & 7.3) that conforms to ISO 10542-1
(international).
NOTE: Use WTORS in accordance with the WTORS#1 manufacturers instruction.
Terminology explained: 1) WTORS: Wheelchair Tie-down Occupant Restraint System
Recommended angles for Tie-Down straps (Fig. 7.2 – 7.3).
30° 45°
Fig. 7.1
Fig. 7.2
1
25° 300 25°
Front Securement Points
1
Fig. 7.3
10° 300 10°
Rear Securement Points
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
25
ENGLISH
DANGER!
· The wheelchair can only be secured by using the tie-down points on the
wheelchair’s frame (Fig. 7.5).
· The tie-down points (2 in the front, 2 in the back) are indicated by the
tie-down symbol (Fig. 7.4). Fit the front straps first, then the rear. Tension
the straps to secure the wheelchair. The wheelchair may not be secured onto
any accessories (wishbones, armrests, anti-tip brackets etc.).
· No changes or replacements must be made to the anchorage points/car
fastenings on the wheelchair, or to constructional elements or parts of the
frame without consulting the manufacturer.
· When the wheelchair is transported in a vehicle without occupant and no
restraint system is available then the wheelchair should be properly stored
and secured in the cargo area during travel.
Fig. 7.4
Fig. 7.5
Q700 M
A
B B
A C
Q700 F
A A
C
B B
Q700 R
B B
A A
C
A Front Tie Down Points. B Rear Tie Down Points. C Direction of Travel.
26
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
7.2 Using the Dahl Docking System
7.2.1 Mid Wheel Drive and Rear Wheel Drive Bases with Sedeo Pro
NOTE: This section for the Dahl Docking System only applies to the MWD and RWD
Bases with Sedeo Pro.
NOTE: For Sedeo Pro Advanced see section 7.2.2. NOTE: This section does not
apply to the FWD, Q700F, Sedeo Pro Advanced UP or the Q700M HD.
CAUTION! The installation should only be performed by a qualified technician.
Read all instructions carefully before proceeding with the installation.
To install Docking Plate use Dahl Adaption Kit (MWD #503683 – RWD #501798)
1. Fit the 8 mm spacer onto the lock plate (Fig. 7.6).
2. Use more spacers to achieve desired thickness with regards to, for
instance, user weight and tire pressure. Additional spacers can be mounted
under the locking station (Fig. 7.7). To align the height of the lock plate
under wheelchair with the docking station fit spacers between the docking
station and the vehicle floor to raise the docking station.
3. Put the five screws through the lock plate, the mandatory 8 mm spacer and
the selected optional spacers (grey in picture) (Fig. 7.8).
WARNING! Do not use any other screws than those supplied from Dahl engineering
(Part #502800 which is Quality 14.9 with Torx Key Size 27). Standard screws
will not be strong enough in the event of a collision.
4. Mount the five screws together with the spacer/spacers and the lock plate
(A) on the underside of the chassis box (Fig. 7.9).
Fig. 7.9
Fig. 7.6
Fig. 7.7
1 mm 2 mm
Optional, max 3 mm
8mm Mandatory Fig. 7.8
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
A
27
ENGLISH
5. Mark where to cut the screws. (Fig. 7.10).
Fig. 7.10
6. Remove the screws together with the spacer/spacers (Fig. 7.11).
Fig. 7.11
7. Cut the screw where the mark is (Fig. 7.12). It is very important that the
fitter checks that the length of the bolts are correct. If bolts are too short
to reach through all the threads – they will not have the strength to carry
the loads required. If bolts are too long the batteries or other wheel chair
components can be damaged. If necessary replace with longer bolts, or shorten
them.
8. Apply Loctite 243 (or an equivalent product) onto the screw (Fig. 7.13).
x5
x5
Fig. 7.12 Fig. 7.13
28
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
9. Attach the five screws together with the plastic spacer/ spacers (to
prevent the batteries from coming into contact with the nuts) and the lock
plate on the underside of the chassis box. Tightening torque: 16-18 Nm/13.3
lb.ft (Fig. 7.14).
Please refer to Section 6.6 of this manual for reverse the procedure to
replace batteries.
Fig. 7.14
7.2.2 Sedeo Pro Advanced – with Q700M Base
NOTE: This section only applies to Sedeo Pro Advanced with Q700M base with a
maximum user weight of 136kg.
NOTE: This section does not apply to the Sedeo Pro Advanced UP.
Fitting the stiffener plate Required tools: · Torx bit T27 · Torque wrench
(16-18Nm) · Angle grinder · Marker
Parts list (Fig. 7.15): 1. Spacer (x2) 2. Nut (x10) 3. Stiffener plate (x1)
For kit shown in Fig. 7.15 contact Dahl engineering.
Instructions a. Select the stiffener plate suitable for the Q-series model. b.
Mount the five screws together with the stiffener plate and
nuts on the underside of the battery box. c. Mark excess screw length. (Fig.
7.16) d. Remove the screws from the assembly and cut to length using
an angle grinder. e. Apply loctite 222 onto the screw and tighten the assembly
to
16-18Nm.
1 2
Fig. 7.15 3
Fig. 7.16
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
29
ENGLISH
Fitting the dahl lock plate
Required tools: · Torx bit T27 · Torque wrench (16-18Nm) · Angle grinder ·
Marker
Parts list: · 501798 Adaptation kit · 500561 Lock plate with bolts · 500673
8mm spacer
Instructions
a. Mount the five screws together with the spacer and lock plate on the
underside of the battery box
b. Mark excess screw length (Fig. 7.17) c. Remove the screws from the assembly
and cut to length using
an angle grinder
d. Apply loctite 222 onto the screw and tighten the assembly to 16-18Nm
e. Level the battery compartment by positioning the two plastic spacers on
either side of the nuts
Nut
Spacer Lock plate
Fig. 7.17 Fig. 7.18
Plastic spacer
Fig. 7.19
Plastic spacer TOP VIEW
Fig. 7.20
BOTTOM VIEW
30
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Final checks for DAHL Docking system
Perform final check by connecting the wheelchair to the docking station. Check
that it is securely locked and make sure that all release methods work as
intended (Fig. 7.15).
A warning tone will sound if the lock plate is not properly engaged.
(A) Release button. (B) Manual operating lever. (C) Emergency release. (D) Red
LED. (E) Green LED. (F) Lock Plate. (G) Lock Pin.
F
D
Fig. 7.21
E
A
B
F
C
Securing the wheelchair in the docking station:
Make sure that the leg rests are not colliding with the ramp or the docking
station when entering the vehicle. 1. Manoeuvre the wheelchair slowly and in a
uniform direction
over the docking station. The lock plate under the wheelchair helps to guide
the wheelchair into place in the docking station. When the lock plate is fully
engaged in the docking station, a spring-action locking pin automatically
secures the lock plate. 2. The docking station is equipped with a control
switch that indicates whether the lock plate is correctly secured in the
docking station. As soon as the lock plate comes into contact with the locking
pin, a warning tone will sound (a highpitched howl), and the red diode/lamp
(LED) in the control panel will light up until the lock plate is either fully
engaged or else the wheelchair is removed from the docking station. 3. As an
indication that the wheelchair is properly secured, the warning tone will
cease, the red diode in the control panel will go out and the green diode lamp
(LED) will light up. 4. Do not forget to buckle up for driving.
Release from the docking station
1. When the vehicle has been brought to a halt, remove the safety belt.
2. To unlock commence by driving the wheelchair forward to release pressure
on the lock pin and then press the red release button in the control panel.
The locking pin will be triggered/released for approx. 5 seconds, after which
the locking pin is automatically locked/activated again. Do not attempt to
reverse out of the docking station until the red LED on the control module,
which indicates the unlock position, has been illuminated. WARNING! Attempting
to reverse the wheelchair before the red LED has been illuminated will result
in blocking the docking stations lock mechanism, which makes it impossible to
reverse. If this happens repeat above unlocking procedure.
3. Move the wheelchair away from the docking station within this 5-second
period.
Manual release in case of electrical failure
1. In the event of electrical failure, a manual emergency release is located
at the front edge of the docking station. Move wheelchair forward to release
pressure on the lock pin and push the red release arm to one side and hold it
there while the wheelchair reverses out of the docking station.
2. A cable-activated manual operating lever can also be fitted (accessory).
The red release arm must pushed to one side and should be held there whilst
the wheelchair moves away.
3. If the described manual release procedures fails, an emergency release
tool made from red plastic comes with each docking station.
Move wheelchair forward to release pressure on the lock pin and place the
emergency release tool in the gap between the locking plate and the docking
station. Push the release tool forward until the locking pin will has been
forced down – after which the wheelchair can be reversed out of the docking
station.
Please also refer to Dahl Engineering instructions for Installation, Use and
Maintenance
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
31
ENGLISH
7.3 The wheelchair as a passenger seat
A wheelchair secured in a vehicle will not provide the equivalent level of
safety and security as a vehicle seating system. Sunrise Medical recommends
that the user transfers to the vehicle seating and uses the vehicle-installed
restraint system wherever possible. Sunrise Medical recognizes that it is not
always practical for the user to be transferred and in these circumstances,
where the user must be transported whilst in the wheelchair, the following
advice must be followed:
DANGER!
· The safety of the user during transportation depends upon the diligence of
the person securing the tie down restraints and they should have received
appropriate instructions and/ or training in their use.
· Wherever possible remove and stow safely away from the wheelchair all
auxiliary equipment, e.g. : crutches, loose cushions, tray tables, etc. i.
Removed and secured separately in the vehicle, or ii. Secured to the
wheelchair, but with energy-absorbing padding placed between the table and the
user.
· Articulating/elevating leg rest should not be used in the elevated position
when the wheelchair and user are being transported.
· If applicable: Reclining backrests should be returned to an upright
position.
· If applicable: Seat elevators should be in the lowest position. · If
applicable: The manual brakes must be firmly applied.
Positioning the occupant restraint
DANGER!
· Belt restraints should make full contact with the shoulder, chest and pelvis
and pelvic belts should be positioned low on the pelvis near the thigh-
abdominal junction (meeting the requirements specified in ISO 7176-19:2008).
· The pelvic restraint belt must be worn low across the front of the pelvis so
that the angle of the pelvic belt is within the preferred zone of 30° to 75°
to the horizontal.
· A steeper (greater) angle within the preferred zone is desirable i.e. closer
to, but never exceeding 75° degrees (Fig. 7.23). i. The upper torso restraint
belt must fit over the shoulder and across the chest as illustrated (Fig.
7.23). Restraint belts must be adjusted as tightly as possible consistent with
user comfort.
· Restraint belt webbing must not be twisted when in use. · Care should be
taken when applying the occupant restraint to
position the seatbelt buckle so that the release button will not be contacted
by wheelchair components during a crash.
Fig. 7.22
55° 30°
Occupant restraint Instruction
DANGER!
· Use a 3-point occupant restraint system to secure the occupant.
· Both pelvic and upper torso restraint belts must be used to restrain the
occupant to reduce the possibility of head and chest impacts with the vehicle
components.
· Restraints should be mounted to the appropriate vehicle pillar and should
not be held away from the body by wheelchair components such as armrest or
wheels (Fig. 7.22).
· Use a suitable positioned headrest when being transported
Fig. 7.23
in a wheelchair.
· Postural supports (lap straps, lap belts) should not be used or relied on for occupant restraint in a moving vehicle unless
75°
they are labelled as meeting the requirements specified in
ISO 7176-19:2008 or SAE J2249.
100 mm
32
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Passenger with a user weight < 22 kg.
When the user being transported is a child, less than 22 kg mass and the
vehicle involved has less than eight (8) seated passengers it is recommended
that they be transferred to an UNCE Regulation 44 compliant child restraint
system (CRS). This type of restraint system provides a more effective occupant
restraint system than the conventional 3 point occupant restraint system and
some CRS systems also include additional postural supports to assist in
maintaining the position of the child when seated.
Parents or care providers may consider the option, in some circumstances, for
their child to remain in their wheelchair whilst in transport due to the level
of posture control and comfort provided by the set up in the wheelchair. We
would recommend in such circumstances that a risk assessment be carried out by
your healthcare professional and relevant competent persons.
Fig. 7.24
100 mm
55° 30°
75°
10-60mm
10-60mm
For use with Dahl Docking system only (Fig. 7.24) When using wheelchair with Dahl Docking system, the floor anchorage points for occupant restraint should be located 10-60 mm outside wheels, on each side.
7.4 Special transport requirements
Using your wheelchair on the train. Before you travel, please contact the
train operator. They will be able to supply details of any special
requirements/ instructions. We advise you to check the following: · Is there a
suitable and intended “wheelchair” area in the
train for wheelchair users (with adequate turning space to manoeuvre)? · Is
there a suitable or designated area on the platform for wheelchair users (with
adequate turning space to manoeuvre)? · Is there suitable boarding access
available to allow you to access the railway carriage and the intended
“wheelchair” area? · Is the boarding access suitable for the combined mass of
the wheelchair and the occupant? · Make sure the slope of the boarding access
is not greater than the dynamic safe slope. (See Section 10) · Any obstacles
or thresholds should not exceed the max kerb climbing capability of your
wheelchair. (See Section 10)
Most train operators will provide assistance provided that arrangements have
been made in advance. We suggest you have you Owner’s Manual ready when
planning your journey and contacted them.
WARNING!
· While driving on a boat or train, make sure that you use driving Profile 1,
as this is the standard profile where the GYRO is deactivated. The continuous
movement of a boat or train, disrupts the GYRO system and the driving
characteristics of your wheelchair.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
33
ENGLISH
Transporting the wheelchair as luggage. Parts of the wheelchair that can
easily be detached should be removed when transporting the wheelchair. Store
these parts securely. e.g.:
A. Remove the seat (& Seating system).
B. Remove the leg rests (& Seating system).
C. Remove the armrests (& Seating system).
D. Fold down the backrest (& Seating system).
· Ensure that any detachable parts are secured with your mobility aid or
separately packed and labelled so they do not get lost during loading and
unloading.
· The wheelchair may be transported by road, rail, sea or air as the batteries
supplied conform to IATA regulations. If the batteries are replaced by non-
IATA approved batteries then they will need to be removed for air travel. Your
dealer can assist in supplying batteries that are IATA approved.
· Before you travel, please contact the appropriate carrier. The travel
operator will be able to supply details of any special
requirements/instructions.
· For information about dimensions and weight of the wheelchair, see (Section
10).
· For information about the batteries in your wheelchair see (Section 6).
· Ensure that any detachable parts are secured with your mobility aid or
separately packed and labelled so they do not get lost during loading and
unloading.
· Take this user manual, the seating system user manual (& Seating System) and
the controller user manual (& Controller) with you. The carrier will need to
refer to the following sections: i. Pushing the wheelchair, (Section 5.8). ii.
How to lock/unlock the controller: & Controller. iii. How to disconnect the
batteries, (Section 6.7) iv. How to disconnect the drive, (Section 5.8)
· Transporting the chair, (Section 7.0). · Medium to long term storage, follow
the instructions,
(Section 8.5).
7.5 General transport warnings
WARNING! · No changes or replacements must be made to the
anchorage points/car fastenings on the wheelchair, or to constructional
elements or parts of the frame without consulting Sunrise Medical. · The
wheelchair should be inspected by a Sunrise Medical authorised dealer/service
agent, before reuse following involvement in any type of vehicle collision.
34
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
8.0 Maintenance & cleaning
The wheelchair’s lifespan is dependent on it being well maintained. For
information concerning specific settings, maintenance or repair work, please
contact your authorized Sunrise dealer. Always be sure to mention the model,
year of manufacture and identification number provided on the identification
plate of the wheelchair when contacting your dealer.
CAUTION! The wheelchair should be serviced by your authorized Sunrise dealer
once a year or, in the case of intensive use, every six months. For a list of
approved authorised dealers in your area please contact Sunrise Medical
Service Centre. The contact details of your local Sunrise medical service
centre can be found on the inside front cover of this booklet. National and
International Website addresses are on the back cover.
8.1 Maintenance
WARNING!
· Loose fasteners should be re-tightened according to the installation instructions. Please refer (unless otherwise specified) to the general table below for needed Torques.
Torque Setting Guide
M4
3.0 Nm
M5
5.9 Nm
M6
10 Nm
M8
25 Nm
M10
48 Nm
M12
84 Nm
Note: it will be necessary to use a torque wrench.
· Chest straps should be replaced at the first indication of damage and/or
excessive wear.
· If a broken or loose component is found, discontinue use immediately and
contact your authorised Sunrise Medical supplier for replacement.
· Check all Velcro fastening straps for correct adhesion when pressed
together.
· Ensure that any contamination, such as fluff, hair, etc is removed from the
Velcro straps. Such contamination may affect adhesion.
Daily checks Perform the daily check routine before driving as described in
chapter 5.1
Weekly checks Perform the weekly check routine before driving as described
below.
Checking Parking brake: This test should be carried out on a level floor with
at least one meter clearance all around the chair. · Switch on the control
system. · Check that the battery gauge remains on, or flashes slowly,
after one second. · Push the joystick slowly forwards until you hear the
parking
brakes operate. · The chair may start to move. · Immediately release the
joystick. You must be able to hear
each parking brake operate, (click), within a few seconds. · Repeat the test a
further 3 times, pushing the joystick
slowly backwards, left and right.
Checking connectors & cables: · Make sure that all connectors are securely
mated. · Check the condition of all cables and connectors for
damage.
WARNING!
· If you are in any doubt about the performance requirements of your
wheelchair contact your Sunrise Medical authorised dealer.
· After performing any maintenance or repairs on the wheelchair you must make
sure that it is functioning correctly before it is used.
· All fasteners must be replaced like for like using the correct length,
tensile strength and materials.
· When replacing self-locking nuts, or nuts/studs secured with a thread
locking solution, ensure that a suitable thread locking solution is reapplied
to the fastener.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
35
ENGLISH
Checking controller: · Check the thin rubber gaiter or boot around the base of
the
joystick shaft for damage or splitting. Check visually only, do not handle the
gaiter. · Make sure that all components of the control system are securely
mounted. Do not over-tighten any securing screws.
Checking controls: · Switch on the hand control Do the lights flash? This
signifies that there is a fault in the electronic system. Refer to chapter 10 for basic troubleshooting’. · Operate all of the electric options, including lights and indicators, (if fitted), to make sure that they work correctly. · With the seating in an elevated position, drive the wheelchair to make sure that the
creep’ mode works which will slow the wheelchair. · Drive the
wheelchair in each of the drive profiles to make sure the wheelchair performs
as it did before.
WARNING!
· If you are in any doubt about the performance requirements of your
wheelchair contact your Sunrise Medical authorised dealer.
· After performing any maintenance or repairs on the wheelchair you must make
sure that it is functioning correctly before it is used.
· A complete inspection, safety check and service should be made by a Sunrise
Medical authorised dealer at least once per year.
· All fasteners must be replaced like for like using the correct length,
tensile strength and materials.
· When replacing self-locking nuts, or nuts/studs secured with a thread
locking solution, ensure that a suitable thread locking solution is reapplied
to the fastener.
· Check all Velcro fastening straps for correct adhesion when pressed
together.
· Ensure that any contamination, such as fluff, hair,etc is removed from the
Velcro straps. Such contamination may affect adhesion.
Monthly checks
Perform the monthly check routine before driving as described below. · All
fasteners should be checked monthly for wear, such as
loose bolts or broken components. · Check all straps monthly for fraying,
ripped seams or other
indications of excessive wear damage. Discontinue use if damage is found.
36
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
8.2 Tyre maintenance and pressures
8.2.1 Tyre pressure
CAUTION! If pneumatic tyres are fitted to your wheelchair it is important to
regularly check the air pressure and for signs of wear. The maximum tyre
pressures are listed in Section 8.3, if in doubt check the markings on the
side of the wheelchair tyre for guidance. NOTE: It is important that drive
wheels are inflated to equal pressures as a pair, and likewise the rear. The
inflator pump provides the safest method of inflating your wheelchair tyres
and the pressure can be checked with a standard motor vehicle pressure gauge.
DANGER! · Do not inflate beyond the maximum allowed tyre pressure.
8.2.2 Tyre wear When inspecting the tyres for signs of wear, look for
significant scuff marks, cuts and a diminished tyre tread. Tyres will need to
be changed when the tread cannot be seen over the complete surface of the
tyre, (Fig.8.1).
Fig. 8.1
8.2.3 Drive wheel tyre repair
To remove the wheel/tyre: Please see below and next page for photographs. ·
Remove the colour ring. · Use a 16 mm AF lug nut to loosen the 3-Socket studs,
(Fig.
8.2). · Jack the base/battery box up and support it using blocks,
(Fig. 8.3). · Remove the 3 studs and pull the wheel away from the hub. ·
Remove the valve cap and let the air out of the tyre by
gently pressing the valve stem with a small screw driver, (Fig. 8.4). · There
are 6 rim studs that must be loosened/tightened in the number order shown,
(Fig.8.5). Use a 5.0 mm Allen key to release/tighten the studs. · Use a 5.0 mm
Allen key to release/tighten the studs. (Fig. 8.5) . · Lift the inner rim off
the tyre wall (Fig. 8.6). · Lift the tyre and tube off the outer rim,
(Fig.8.7). · Gently get a hold of the inner tube just behind the valve. ·
Carefully feed the tube out of the tyre, (Fig.8.8). · Ensure all parts are
clean before reassembling, (Fig.8.9).
To refit · Place the tube inside the tyre and rest the tyre on the outer
rim. · Align the valve stem with the cut out in the rim. · Face the valve stem
outward. · Place the inner rim over the tyre, tube and outer rim. · Align the
cut out to fit over the valve stem and match it up
to the cut out in the outer rim, (Fig.8.10). · Make sure the stud mounts are
in line on both rims. · Tighten the studs in the sequence shown in Fig.8.5,
taking
care not to pinch the tube. · Slowly inflate to the pressures quoted in
section 8.1.1 . · Refit the wheel back onto the motor shaft and fix it safely
with the 3 studs to a torque of 34Nm.
For solid tyres the sequence is the same, just discount the references to the
inner tube and valve.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
37
ENGLISH
3mm
Fig. 8.2 Fig. 8.4 Fig. 8.6 Fig. 8.8
38
Fig. 8.3
Fig. 8.5 Fig. 8.7
1 6
4
3 5
2
Fig. 8.9
Fig. 8.10 Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
IMPORTANT: Check all parts, including wheels and studs and mounting faces of
hub and wheels, for dirt, rust or damage. Use a wire brush to remove dirt and
rust, replace any damaged parts.
Careless installation of wheels on a vehicle is a major cause of tyre and
wheel problems. Proper installation, including nut torque, is essential to
safe, economical, trouble free service. Use only the specified sizes and types
of studs and nuts.
Tighten the nuts a quarter turn at a time following the crisscross sequence
shown in Fig. 8.5. This is very important. Failure to tighten the nuts in this
criss-cross sequence will cause a misalignment of the wheel. Continue until
all nuts are tightened to the manufacturer’s specified torque.
CAUTION: Improper torque can cause distortion, fatigue cracks or alignment
problems. After running the vehicle for a short distance, check the nuts for
tightness. Parts will usually seat naturally and torque on nuts will drop.
Retighten all nuts to the specified torque.
The information above is for a tyre professional and should not be attempted
by individuals not properly trained & equipped.
8.2.4 Removing the castor wheels (M base) (Fig.8.11). · Use a 17.0 mm
spanner/socket to undo the axle bolt. · Remove the nyloc nut.
Removing the castor wheels (F/R base) (Fig.8.12) · Use a 13.0 mm wrench and 5
mm Allen key to undo loosen
the screws. · Remove both screws
Refitting: When refitting do not try to force the bolt through. Gently move
the wheel back and forth until the bolt slips through then tighten to a torque
of 14Nm.
WARNING! Always use a new nyloc nut when refitting.
Fig. 8.11
Fig. 8.12
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
39
Annually Monthly Weekly Daily*
ENGLISH
Maintenance & Inspection Schedule
Daily check routine as described in chapter 5.1
Weekly check routine as described in chapter 8.1
Clean wheelchair upholstery & Seating system
Complete inspection, safety check and service should be made by a Sunrise
Medical authorised dealer.
8.3 Wheels & tyres maintenance
To ensure that your wheelchair functions properly, it is essential that the
tires are kept at the correct pressure. The correct tyre pressure is indicated
on the side of the tyre. Tyres that are too soft will have a negative effect
on the wheelchair’s performance. Moving the wheelchair will require more
energy, making more demands on the batteries. Furthermore, wear on under
inflated tyres is increased When inspecting the tyres for signs of wear, look
for significant scuff marks, cuts and a diminished tyre tread. Tyres will need
to be changed when the tread cannot be seen over the complete surface of the
tyre.
Castor wheel 6″ 9″ (2.80/2.50-4)
10″ (3.00-4)
Drive wheel 14″ (3.00-8)
Q700 M Q700 F Q700 R Q700 F Q700 R
Q700 M Q700 F Q700 R
Max. tyre pressure Solid wheels 2.4 bar max.
2.4 bar max.
Max. tyre pressure 3.5 bar max.
35 PSI 35 PSI
50 PSI max.
DANGER!
· Do not inflate beyond the maximum allowed tyre pressure. · Never use a
forecourt pump · Before tyres are repaired they must first be fully deflated!
40
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
8.4 Lighting maintenance:
DANGER! Maintaining lights and indicators is a safety critical task. If your
lights and indicator system shows a defect, please contact your Sunrise
Medical Approved Dealer. All lights and indicators are state of the art LED
low energy, no maintenance units. There are no light bulbs used. The high
intrinsic reliability of these units means that they are extremely unlikely to
fail under normal usage. If a failure should occur, (may be as a result of an
impact), the damaged light assembly must be replaced in its entirety. The
individual LED’s cannot be replaced.
CAUTION! · We recommend the use of Sunrise Medical authorized spare
parts only. · Be advised that all lighting circuits are electronically
protected. In the event of a short circuit current will be limited to a safe
level. Once the fault is removed the system resets automatically.
8.5 Cleaning and disinfection
The wheelchair should be wiped over once per week with a slightly damp, not
wet, cloth and any fluff or dust that has accumulated around the motors should
be blown or dusted away.
CAUTION! Make sure that you dry all parts of your wheelchair if it becomes wet
or damp after cleaning or if it is used in a wet or damp atmosphere.
DANGER! It is important that should the wheelchair be used by more than one
person it is cleaned thoroughly to ensure there is no cross infection.
Hygiene measures when being re-used: Prior to the wheelchair being re-used, it
must be carefully prepared. All surfaces which come into contact with the user
must be treated with a disinfection spray. To do this, you must use a suitable
disinfectant for rapid alcoholbased disinfection of medical products and
medical devices. Please take into account the manufacturer’s instructions for
the disinfectant you are using.
CAUTION! · Do not use solvents, bleaches, abrasives, synthetic
detergents, wax polishes or aerosols. · Disinfectants may be used in dilution
as specified by their
manufacturer. · Ensure surfaces are rinsed with clean water and dried
thoroughly.
WARNING! · Always read the label on any commercial or domestic
cleaning substances. · Always follow the instructions carefully.
Cleaning controls: & Controller
Should the control of your wheelchair become soiled or dirty, it can be wiped
with a damp cloth with a dilute disinfectant until clean.
DANGER! Important: If the wheelchair is to be used by more than one person,
follow the cleaning and disinfection instructions carefully to ensure that
there is no cross infection.
8.6 Medium to long term storage:
When storing your wheelchair for long periods of time (in excess of one week),
follow these simple instructions: · Fully charge the wheelchair for at least
24 hours. · Disconnect the charger. · Disconnect the batteries.
WARNING! Never store your wheelchair: · Outside. · In direct sunlight,
(plastic parts may discolour). · Near a source of direct heat. · In a damp
environment. · In a cold environment. · With the batteries/battery boxes
connected, (even if the
controller is switched off).
Avoiding all of the above will minimise battery deep cycle discharge and
extend battery lifetime. When returning the wheelchair to use, please
reconnect the batteries/battery boxes and charge the wheelchair for at least
24 hours before use.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
41
ENGLISH
9.0 Disposal
The symbols below mean that in accordance with local laws and regulations your
product should be disposed of separately from household waste. When this
product reaches the end of its life, take it to the local collection point
designated by local authorities. The separate collection and recycling of your
product at the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects the environment. Ensure
you are the legal owner of the product prior to arranging for the product
disposal in accordance with the above recommendations and national
requirements.
Pb
In the following section, there is a description of the materials used on the
wheelchair, in view of the disposal or recycling of the wheelchair and its
packaging. There may also be special local regulations in force with regard to
disposal or recycling, these must be taken into account when disposing of your
wheelchair. (This can include the cleaning or decontamination of the
wheelchair prior to disposal).
Aluminium: Castor forks, wheels, side-guards for the chassis. Steel: Fixing
points, quick-release axle Plastic: Handles, tube stoppers, castors and
wheel/tyre Packaging: Plastic bags made of soft polyethylene, cardboard
Disposal or recycling should be done through a licensed agent or authorised
place of disposal. Alternatively your wheelchair may be returned to your
dealer for disposal.
42
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
10.0 Trouble shooting
If the wheelchair is not working as it should, check the following points. ·
Check whether the batteries are charged. · Turn the wheelchair off and then
back on again. · Check whether the battery plugs are all securely in place. ·
Check whether the freewheel lever is in the DRIVE position · Check the
position of the speed regulator. · Make sure that the controller isn’t locked
& Controller
If the problem has not been resolved: · & Controller
11.0 Technical specifications: Applicable norms / standards
This product complies with the regulations and guidelines for medical aids and
carries a CE symbol. The product meets the requirements and standards below.
These are checked by independent institutions.
Standard Medical Device Regulation (EU) 2017/745
EN 12182: 2012 Class B
EN 12184: 2014 Class B
ISO 7176-8: 2014 ISO 7176-9: 2009 ISO 7176-14: 2008 ISO 7176-16: 2012
Definition / description
Applicable as mentioned in Appendix 1
Assistive products for persons with disability – General requirements and test methods
Q700 M
Q700 F
Q700 R
Q700 M HD
Q700 UP M/F Sedeo Pro Advanced UP
Electrically powered wheelchairs, scooters and their chargers Requirements and test methods
Q700 M
Q700 F
Q700 R
Q700 M HD
Q700 UP M/F Sedeo Pro Advanced UP
Requirements and test methods for impact, static and fatigue strengths
Climate tests for electric wheelchairs
Requirements and test methods for control systems for electric wheelchairs
Requirements for resistance to ignition of upholstered parts
ISO 7176-19: 2008
ISO 7176-19: 2008 Dahl docking
Wheelchairs – Part 19: Wheeled mobility devices for use as seats in motor vehicles: The Q-series meet the crash test requirements as described in ISO 7176-19
Q700 M
Q700 M HD
Q700 F
Q700 R
Q700 UP M/F Sedeo Pro Advanced UP
Wheelchairs – Part 19: Wheeled mobility devices for use as seats in motor vehicles: The Q-series meet the crash test requirements as described in ISO 7176-19
Q700 M
Q700 R
Test Dummy Weight
SEDEO Pro 160 kg 205 kg
SEDEO Pro 160 kg 205 kg
N/A N/A N/A N/A
SEDEO Pro 78 kg
SEDEO Pro 78 kg
SEDEO Pro Advanced
160 kg
120 kg SEDEO Pro Advanced
160 kg
120 kg N/A N/A N/A N/A
SEDEO Pro Advanced
78 kg 78 kg SEDEO Pro Advanced 78 kg
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
43
ENGLISH
Model
Type / configuration Mid wheel drive
Maximum user weight EN12184 class:
160 kg
Q700 series
Q700 M
B
353 lbs.
Description
Total length (including legrests)
Mid wheel drive
Q700 M Sedeo Pro Advanced
Central footplate
Q700 M Sedeo Pro
Swingaway hangers
Total width
Q700 M
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700 M Sedeo Pro Advanced
Q700 M Sedeo Pro
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700 M
Mid wheel drive
Min. braking distance at maximum speed
Q700 M
Static stability
Q700 M Sedeo Pro Advanced Downwards / Upwards / Sideways
Q700 M Sedeo Pro
Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action: Obstacles, rugged terrain, driving on slopes, exposure to temperatures below freezing point and frequent use of powered seat options.
6 kph
80 Ah batteries
8 kph
80 Ah batteries
10 kph
80 Ah batteries
12.5 kph
80 Ah batteries
Climbing capability for obstacles
Q700 M
Mid wheel drive
Max speed forward
Q700 M
Mid wheel drive
Turning radius
Q700 M
Mid wheel drive
Turning space / reversing width
Q700 M
Mid wheel drive
Q700 M Q700 M Q700 M Q700 M
Ground clearance
Q700 M
Mid wheel drive
Metric system values Minimum Maximum
1070 mm 1100 mm 1190 mm 1190 mm
622 mm 660 mm
160 kg 145 kg
180 kg 175 kg
43 kg 50.2 kg 23.5 kg
6° 3100 mm
8°/19°/14° 25°/25°/21° 8°/19°/14° 25°/25°/21°
32.5 km 30.0 km 27.5 km 25.0 km
40.0 km 37.5 km 35.0 km 32.5 km
75 mm 100 mm
6 kph
560 mm 630 mm
1100 mm
90 mm
Imperial system values & alternative
Minimum
Maximum
41.1″ 46.8″
24.5″
43.3″ 46.8″
26.0″
353 lbs. 320 lbs.
397 lbs. 386 lbs.
+ 94.8 lbs. + 110.7 lbs.
51.8 lbs.
10.5 % 122.0″
14%/34%/25% 47%/47%/38% 14%/34%/25% 47%/47%/38%
20.2 miles 18.6 miles 17.1 miles 15.5 miles
24.9 miles 23.3 miles 21.7 miles 20.2 miles
2.95″
3,94″
4 mph
22.0″
24.8″
43.0″
3.5″
Description Maximum battery dimensions (l x b x h) Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
44
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Model
Type / configuration Mid wheel drive
Maximum user weight EN12184 class:
205 kg
Q700 series
Q700 M HD
B
452 lbs.
Description
Total length (including legrests)
Mid wheel drive
Q700 M HD
Central footplate
Q700 M HD
Swingaway hangers
Total width
Q700 M HD
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700 M HD
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700 M HD Mid wheel drive
Min. braking distance at maximum speed
Q700 M
Static stability
Q700 M HD
Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action: Obstacles, rugged terrain, driving on slopes, exposure to temperatures below freezing point and frequent use of powered seat options.
8 kph
80 Ah batteries
Climbing capability for obstacles
Q700 M HD
Mid wheel drive
Max speed forward
Q700 M HD
Mid wheel drive
Turning radius
Q700 M HD
Mid wheel drive
Turning space / reversing width
Q700 M HD
Mid wheel drive
Q700 M HD
Ground clearance
Q700 M HD
Mid wheel drive
Metric system values Minimum Maximum
1070 mm 1100 mm 1190 mm 1190 mm
622 mm 660 mm
145 kg
175 kg
43 kg 50.2 kg 23.5 kg
6° 3100 mm
8°/19°/14° 25°/25°/21°
25.0 km 75 mm 8 kph 560 mm 630 mm 1100 mm 90 mm
Imperial system values & alternative
Minimum
Maximum
41.1″ 46.8″
24.5″
43.3″ 46.8″
26.0″
320 lbs.
386 lbs.
+ 94.8 lbs. + 110.7 lbs.
51.8 lbs.
10.5 % 122.0″
14%/34%/25% 47%/47%/38%
15.5 miles
2.95″
5 mph
22.0″
24.8″
43.0″
3.5″
Description Maximum battery dimensions (l x b x h) Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
45
ENGLISH
Model
Type / configuration Front wheel drive
Maximum user weight EN12184 class:
160 kg
Q700 series
Q700 F
B
353 lbs.
Description
Total length (including legrests)
Front wheel drive
Q700 F Sedeo Pro Advanced
Q700 F Sedeo Pro
Total width
Q700 F
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700 F Sedeo Pro Advanced
Q700 F Sedeo Pro
Central footplate Central footplate
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700 F
Front wheel drive
Min. braking distance at maximum speed
Q700 F
Static stability
Q700 F Sedeo Pro Advanced Downwards / Upwards / Sideways
Q700 F Sedeo Pro
Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action: Obstacles, rugged terrain, driving on slopes, exposure to temperatures below freezing point and frequent use of powered seat options.
6 kph
80 Ah batteries
8 kph
80 Ah batteries
10 kph
80 Ah batteries
12.5 kph
80 Ah batteries
Climbing capability for obstacles
Q700 F
Front wheel drive
Max speed forward
Q700 F
Front wheel drive
Turning radius
Q700 F
Front wheel drive
Turning space / reversing width
Q700 F
Front wheel drive
Q700 F Q700 F Q700 F Q700 F
Ground clearance
Q700 F
Front wheel drive
Metric system values Imperial system values & alternative
Minimum Maximum
Minimum
Maximum
1280 mm 1340 mm 1280 mm 1340 mm
640 mm 640 mm
50,39″ 50,39″
25,2″
52,8″ 52,8″
25,2″
133 kg 134 kg
154 kg 155 kg
293 lbs. 295 lbs.
339 lbs. 342 lbs.
43 kg 48.4 kg 23.5 kg
+ 94.8 lbs. + 106.7 lbs.
51.8 lbs.
6° 2900 mm
10.5 % 114.2″
9°/9°/9° 15°/15°/12° 15.8%/15.8%/15.8% 26%/26%/21.2% 9°/9°/9° 15°/15°/12° 15.8%/15.8%/15.8% 26%/26%/21.2%
32.5 km 30.0 km 27.5 km 25.0 km
40.0 km 37.5 km 35.0 km 32.5 km
70 mm
6 kph 10 kph
735 mm
1240 mm
60mm
20.2 miles 18.6 miles 17.1 miles 15.5 miles
24.9 miles 23.3 miles 21.7 miles 20.2 miles
2.75″
4 mph
6.2 mph
28.9″
48.8″
2.36″
Description Maximum battery dimensions (l x b x h) Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
46
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Model Type / configuration
Rear wheel drive Maximum user weight EN12184 class:
160 kg
Q700 series
Q700 R
B
353 lbs.
Description
Total length (including legrests)
Rear wheel drive
Q700 R Sedeo Pro
Swingaway hangers
Total width
Q700 R
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700 R Sedeo Pro
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700 R
Rear wheel drive
Min. braking distance at maximum speed
Q700 R
Static stability
Q700 R Sedeo Pro Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action:
Obstacles, rugged terrain, driving on slopes, exposure to temperatures below
freezing point and frequent use of powered seat options.
6 kph
80 Ah batteries
Q700 R
8 kph
80 Ah batteries
Q700 R
10 kph
80 Ah batteries
Q700 R
12.5 kph
80 Ah batteries
Q700 R
Climbing capability for obstacles
Rear wheel drive
Q700 R
Climbing capability with kerbclimber for obstacles
Rear wheel drive
Q700 R
Max speed forward
Q700 R
Rear wheel drive
Turning radius
Q700 R
Rear wheel drive
Turning space / reversing width
Q700 R
Rear wheel drive
Ground clearance
Q700 R
Rear wheel drive
Metric system values Imperial system values & alternative
Minimum Maximum
Minimum
Maximum
1100 mm 1180 mm 640 mm 640 mm
43.7″ 25.2″
46.4″ 25.2″
134 kg 155 kg
295 lbs.
342 lbs.
43 kg 48.4 kg 24.2 kg
+ 94.8 lbs. + 106.7 lbs.
53.4 lbs.
6° 2100 mm
10.5 % 82.7″
9°/9°/9° 13°/15°/ 13° 15.8%/15.8%/ 15.8% 23% / 26% / 23%
32.5 km 30.0 km 27.5 km 25.0 km
40.0 km 37.5 km 35.0 km 32.5 km
80 mm
100 mm
6 kph 10 kph
950 mm
1285 mm
65mm
20.2 miles 18.6 miles 17.1 miles 15.5 miles
24.9 miles 23.3 miles 21.7 miles 20.2 miles
3.14″
3.9″
4 mph
6.2 mph
37.4″
50.6″
2.55″
Description Maximum battery dimensions (l x b x h) Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
50 Ah / 60 Ah / 80 Ah
24 V
12 A (rms)
& Controller manual
Class 2 double insulated
47
ENGLISH
Model Type / configuration
Mid wheel drive Maximum user weight EN12184 class:
Description
Total length (including legrests)
Mid wheel drive – Central footplate
Q700-UP M
Total width
Q700-UP M
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700-UP + Sedeo Pro Advanced UP
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700-UP M Mid wheel drive
Min. braking distance at maximum speed
Q700-UP M
Static stability
Q700-UP M
Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action:
Obstacles, rugged terrain, driving on slopes, exposure to temperatures below
freezing point and frequent use of powered seat options.
6 kph
80 Ah batteries
Q700-UP M
10 kph
80 Ah batteries
Q700-UP M
12.5 kph
80 Ah batteries
Q700-UP M
Climbing capability for obstacles
Mid wheel drive
Q700-UP M
Max speed forward
Q700-UP M
Mid wheel drive
Turning radius
Q700-UP M
Mid wheel drive
Turning space / reversing width
Q700-UP M
Mid wheel drive
Ground clearance
Q700-UP M
Mid wheel drive
120 kg
Q700 series
Q700-UP M
B
265 lbs.
Metric system values Imperial system values & alternative
Minimum Maximum
Minimum
Maximum
1070 mm 1130 mm 622 mm 660 mm
41.1″ 24.5″
44.5″ 26.0″
160 kg
180 kg
353 lbs.
397 lbs.
45.8 kg 53.8 kg 23.5 kg
+ 101 lbs. + 118.6 lbs.
51.8 lbs.
6° 3010 mm
10.5 % 118.5″
8°/19°/14° 25°/25°/21° 14%/34%/25% 47%/47%/38%
32.5 km 27.5 km 25.0 km
40.0 km 35.0 km 32.5 km
75 mm
80 mm
6 kph
10 kph
560 mm 630 mm
1100 mm
90 mm
20.2 miles 17.1 miles 15.5 miles
24.9 miles 21.7 miles 20.2 miles
2.95″
3.15″
4 mph
6.2 mph
22.0″
24.8″
43.0″
3.5″
Description Maximum battery dimensions (l x b x h). Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
48
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
60 Ah / 80 Ah
24V
12 A (rms)
See Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
60 Ah / 80 Ah
24V
12 A (rms)
See Controller manual
Class 2 double insulated
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
Model Type / configuration
Front wheel drive Maximum user weight EN12184 class:
120 kg
Q700 series
Q700-UP F
B
265 lbs.
Description
Total length (including legrests)
Front wheel drive – Central footplate
Q700-UP F
Total width
Q700-UP F
14″ Drive wheels
Total weight
Basic configuration, with batteries
Q700-UP + Sedeo Pro Advanced UP
Total weight influencers
Batteries
60 Ah GEL (C20) (Set of 2)
80 Ah GEL (C20) (Set of 2)
Transport weight of the heaviest part
Dynamic stability: Rated slope
Q700-UP F Front wheel drive
Q700-UP F UP
Min. braking distance at maximum speed
Q700-UP F
Static stability
Q700-UP F
Downwards / Upwards / Sideways
Range of action
NB: The following aspects have a negative influence on the range of action:
Obstacles, rugged terrain, driving on slopes, exposure to temperatures below
freezing point and frequent use of powered seat options.
6 kph
80 Ah batteries
Q700-UP F
10 kph
80 Ah batteries
Q700-UP F
12.5 kph
80 Ah batteries
Q700-UP F
Climbing capability for obstacles
Front wheel drive
Q700-UP F
Max speed forward
Q700-UP F
Front wheel drive
Turning radius
Q700-UP F
Front wheel drive
Turning space / reversing width
Q700-UP F
Front wheel drive
Ground clearance
Q700-UP F
Front wheel drive
Metric system values Minimum Maximum
Imperial system values & alternative
Minimum
Maximum
1270 mm 1320 mm 640 mm
50.0″
51.96″
25.2″
133 kg
154 kg
293 lbs.
339 lbs.
45.8 kg 53.8 kg 23.5 kg
+ 101 lbs. + 118.6 lbs.
51.8 lbs.
6° 2690 mm
10.5 % 106.0″
9°/9°/9° 12.8°/21.4°/18.3° 15.8%/15.8%/15.8% 22.7%/39.2%/33%
32.5 km 27.5 km 25.0 km
40.0 km 35.0 km 32.5 km
75 mm
6 kph
10 kph
735 mm
1400 mm
71 mm
20.2 miles 17.1 miles 15.5 miles
24.9 miles 21.7 miles 20.2 miles
2.95″
4 mph
6.2 mph
28.9″
55.12″
2.79″
Description Maximum battery dimensions, (l x b x h). Battery capacity Maximum
permissible charging voltage Maximum charging current Connector type
Insulation
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
Metric system values
Minimum
Maximum
260 x 172 x 210 mm
60 Ah / 80 Ah
24V
12 A (rms)
See Controller manual
Class 2 double insulated
Imperial system values & alternative
Minimum
Maximum
10.2 x 6.8 x 8.3″
60 Ah / 80 Ah
24V
12 A (rms)
See Controller manual
Class 2 double insulated
49
ENGLISH
12.0 Warranty
THIS GUARANTEE DOES NOT AFFECT YOUR LEGAL RIGHTS IN ANY WAY.
Sunrise Medical* provides a guarantee, as set out in the warranty conditions,
for products to its customers covering the following.
Warranty conditions:
1. Should a part or parts of the product require repair or replacement as a
result of a manufacturing and/or material fault within 24 months, then the
affected part or parts will be repaired or replaced free of charge. The
warranty will only cover manufacturing defects
2. To enforce the warranty, please contact the supplier of your wheelchair
e.g. the Sunrise Medical Approved dealership or Healthcare provider with the
exact details of the nature of the difficulty. Should you be using the product
outside the area covered by the Sunrise Medical customer service agent,
repairs or replacement will be carried out by another agency as designated by
the manufacturer The product must be repaired by a Sunrise Medical designated
Customer Service agent, (dealer).
3. For parts, which have been repaired or exchanged within the scope of this
warranty, we provide a warranty in accordance with these warranty conditions
for the remaining warranty period for the product in accordance with point 1.
4. For original spare parts which have been fitted at the customer’s expense,
these will have a 12 months guarantee, (following the fitting), in accordance
with these warranty conditions.
5. Claims from this warranty shall not arise, if a repair or replacement of a
product or a part is required for the following reasons: a. Normal wear and
tear, which include but is not limited to the following parts where fitted;
batteries, armrest pads, upholstery, tyres, brakes shoes, ferrules, etc. b.
Any overloading of the product, please check the EC label for maximum user
weight. c. The product or part has not been maintained or serviced in
accordance with the manufacturer’s recommendations as shown in the user
instructions and/or the service instructions. d. Accessories have been used
which are not specified as original accessories. e. The product or part having
been damaged by neglect, accident or improper use. f. Changes/modifications
have been made to the product or parts, which deviate from the manufacturer’s
specifications. g. Repairs have been carried out, before our Customer Service
has been informed of the circumstances.
6. This guarantee is subject to the law of the country in which the product
was purchased from Sunrise Medical.
7. Life expectancy We estimate a life expectancy of five years for this
product, provided that: · It is used in strict accordance with the intended
use as set out in this document. · All maintenance and service requirements
are met. The estimated life expectancy can be exceeded if the product is
carefully used and properly maintained, provided that technical and scientific
advances do not result in technical limitations. The life expectancy can also
be considerably reduced by extreme or incorrect usage. The fact that we
estimate a life expectancy for this product does not constitute an additional
warranty.
- Means the Sunrise Medical facility from which the product was purchased.
Additional Notes For Australia Only: i. For goods provided by Sunrise medical Pty Ltd in Australia, our goods come with a guarantee by Sunrise Medical that cannot be
excluded under Australian Consumer Law. ii. You are entitled to a replacement or refund for a major failure and for compensation for any foreseeable loss or damage. iii. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not
amount to a major failure. iv. The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the goods
to which the warranty relates.
50
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
ENGLISH
13.0 Nameplate
TYPE: Q700 M
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-03-09 203204229996547
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7M20100330 max
kg
160 kg 350 kg 6 km/h max 6° 60kg/290kg/60kg
Q700 M/F/R / Q700 M HD / Q700-UP M / Q700-UP F Product Name/SKU Number.
Maximum safe slope with anti-tip tubes fitted,
Depends on wheelchair setting, posture and
max X°
physical capabilities of the user.
kg
Maximum user weight.
XXX kg
kg
Load Maximum.
XXX kg
XX km/h
kg XXkg/XXXkg/XXkg
Maximum speed. Maximum axle loading.
CE Mark.
User’s Guide. Indicates electrical / electronic equipment must be disposed of in accordance with the WEEE regulation. XXXX-XX-XX Date of manufacture.
Serial number.
This symbol means Medical Device.
Manufacturer’s address.
ISO 7176-19:2008
Crash tested according to ISO 7176-19:2008.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
51
FRANÇAIS
Pour toute question relative à l’utilisation, à l’entretien ou à la sécurité
de votre fauteuil roulant, contactez votre revendeur agréé Sunrise Medical. Si
vous ne connaissez aucun revendeur dans votre région ou si vous avez des
questions supplémentaires, vous pouvez écrire ou téléphoner à : Sunrise
Medical S.A.S ZAC de la Vrillonnerie 17 Rue Mickaël Faraday 37170 Chambray-
Lès-Tours Tel : +33 (0) 247554400 Fax : +30 (0) 247554403
www.sunrisemedical.fr
Tampon et signature du revendeur
52
Sommaire
1.0 Informations utilisateur ……………………………………….. 53 1.1 À propos du présent
manuel d’utilisation …………………53 1.2 Informations
complémentaires………………………………..53 1.3 Symboles utilisés dans le manuel
…………………………….54
2.0 Sécurité …………………………………………………………….. 55 2.1 Symboles et étiquettes apposés
sur le produit ………….55 2.2 Sécurité : Température……………………………………………55 2.3
Sécurité : Organes mobiles ……………………………………..56 2.4 Sécurité : Rayonnement
électromagnétique……………..56 2.5 Sécurité : Risque d’étouffement ………………………………57
2.6 Sécurité : Utilisation d’un élévateur fixé à un véhicule .57 2.7 Sécurité
: Tablettes…………………………………………………57 2.8 Sécurité : Soulever le fauteuil roulant
………………………57
3.0 Usage prévu du fauteuil roulant …………………………….. 57 3.1 Champ d’application :
L’utilisateur …………………………..57 3.2 Champ d’application : Environnement de
l’utilisateur ..59
4.0 Configuration du fauteuil roulant …………………………… 60 4.1 Système
d’assise…………………………………………………….60 4.2 Profondeur d’assise ………………………………………………..60
4.3 Hauteur d’assise …………………………………………………….60 4.4 Centre de
gravité……………………………………………………60 4.5 Hauteur et profondeur du boîtier de commande
………60 4.6 Programmation du système de commande ………………60 4.7 Ceinture de bassin
/ ceinture de positionnement………61
5.0 Utilisation du fauteuil roulant ……………………………….. 62 5.1 Vérification du
fauteuil roulant avant utilisation ………..62 5.2 Monter et descendre du
fauteuil……………………………..63 5.3 Conduite du fauteuil roulant……………………………………63 5.4
Virages ………………………………………………………………….64 5.5 Freinage et arrêt d’urgence
…………………………………….64 5.6 Utilisation en pente………………………………………………..65 5.7 Obstacles
et trottoirs :…………………………………………….66 5.8 Pousser le fauteuil roulant
………………………………………67 5.9 Options d’assise (électriques) ………………………………….68
6.0 Batteries, recharge et autonomie …………………………… 69 6.1 Batteries
……………………………………………………………….69 6.2 Recharger les batteries : …………………………………………70
6.3 Autonomie de votre véhicule :…………………………………71 6.4 Garantie des batteries
:…………………………………………..71 6.5 Remplacement des batteries …………………………………..72 6.6
Déconnexion des batteries pour le transport aérien ….72
7.0 Transport …………………………………………………………… 74 7.1 Transport du fauteuil à bord d’un
véhicule motorisé….74 7.2 Utilisation du système d’arrimage Dahl…………………….76
7.3 Utilisation du fauteuil comme siège passager……………81 7.4 Conditions
spéciales de transport ……………………………82 7.5 Avertissements généraux relatifs au
transport…………..83
8.0 Entretien et nettoyage …………………………………………. 84 8.1
Entretien……………………………………………………………….84 8.2 Entretien et pression des pneus
………………………………86 8.3 Maintenance des roues et des pneus……………………….89 8.4
Entretien des feux : ………………………………………………..90 8.5 Nettoyage et
désinfection……………………………………….90 8.6 Entreposage à moyen et long terme :
……………………..90
9.0 Enlèvement………………………………………………………… 91 10.0 Dépannage………………………………………………………..
92 11.0 Caractéristiques techniques : Normes en vigueur ……. 92 12.0
Garantie…………………………………………………………… 99 13.0 Plaque signalétique…………………………………………..
100
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
FRANÇAIS
1.0 Informations utilisateur
Nous vous remercions d’avoir choisi un fauteuil roulant Sunrise Medical.
Sunrise Medical proposent des produits de mobilité de qualité conçus pour
renforcer votre indépendance et faciliter la réalisation de vos activités
quotidiennes.
Dans le cadre d’une initiative d’amélioration continue de produit, Sunrise
Medical se réserve le droit de modifier les spécifications et le modèle sans
préavis. Toutefois, toute modification d’informations aux utilisateurs
existants sera communiquée clairement si essentiel à leur sécurité.
En outre, certaines fonctions et options disponibles ne sont pas compatibles
avec toutes les configurations du fauteuil.
Toutes les dimensions suivantes sont approximatives et sujettes à des
modifications.
La durée de vie prévue pour ce fauteuil est de cinq années. N’utilisez ET
n’installez aucun composant tiers sur le fauteuil, à moins qu’ils n’aient été
formellement approuvés par Sunrise Medical.
1.1 À propos du présent manuel d’utilisation
Le présent manuel d’utilisation vous aidera à utiliser et à entretenir votre
fauteuil roulant en toute sécurité. L’intégralité du manuel d’utilisation
englobe quatre fascicules :
· Manuel d’utilisation générale du fauteuil roulant (le présent fascicule) ·
Manuel d’utilisation du système d’assise · Manuel d’utilisation du boîtier de
commande · Le manuel d’utilisation du chargeur de batterie
Si nécessaire, ce manuel d’utilisation général désigne les autres manuels comme affiché sur le tableau ci-dessous :
& Système d’assise :
Renvoie au manuel d’utilisation du système d’assise.
& Boîtier de commande :
Renvoie au manuel d’utilisation du boîtier de commande.
& Chargeur de batteries :
Renvoie au manuel d’utilisation du chargeur de batterie.
Ne pas utiliser le fauteuil roulant avant d’avoir bien lu et compris tous les
dépliants concernés !
Si l’un des fascicules venait à manquer lors de la livraison de votre
fauteuil, veuillez le signaler immédiatement à votre revendeur.
1.2 Informations complémentaires
Adressez-vous à votre service après-vente Sunrise Medical, compétent et agréé,
pour toute question concernant l’utilisation, la maintenance ou la sécurité de
votre fauteuil roulant. S’il n’y a aucun revendeur près de chez vous ou si
vous avez des questions, contactez-nous par courrier ou par téléphone à
l’adresse suivante. Pour toute information sur les avis de sécurité et rappels
de produits, rendez-vous sur www.sunrisemedical.fr
DC AB
E FG
Si vous souffrez de déficience visuelle, ce document peut être consulté en
format PDF
sur
www.sunrisemedical.fr
ou vous être envoyé en grands caractères, sur demande.
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
53
FRANÇAIS
1.3 Symboles utilisés dans le manuel
DANGER !
Risque potentiel de blessures, voire de blessures graves ou mortelles
AVERTISSEMENT ! Risque potentiel de blessures
ATTENTION !
Risque potentiel d’endommagement du matériel
En sa qualité de fabricant, SUNRISE MEDICAL, déclare que ce fauteuil est conforme au règlement sur les dispositifs médicaux (2017/745).
REMARQUE : Conseil d’utilisation générale. Le non-respect des présentes
instructions peut causer des blessures physiques, l’endommagement du matériel
ou la dégradation de l’environnement.
Avis à l’utilisateur et/ou au patient : Tout incident grave en rapport avec le
dispositif doit être signalé au fabricant et aux autorités compétentes de
l’État membre dans lequel réside l’utilisateur et/ou le patient.
Adaptations spéciales pour B4Me Afin de vous assurer que votre produit B4Me
fonctionne de manière performante comme prévu par le fabricant, Sunrise
Medical vous recommande vivement de lire et de comprendre toutes les
informations utilisateur fournies avec votre produit B4Me avant de l’utiliser
pour la première fois.
Sunrise Medical recommande également que les informations utilisateur ne
soient pas jetées après leur lecture, mais qu’elles soient conservées en toute
sécurité afin d’être consultées ultérieurement.
Combinaison de dispositifs médicaux Il est possible de combiner le présent
dispositif médical avec un ou plusieurs autres dispositifs ou produits. Vous
trouverez sur www.sunrisemedical.fr toutes les informations utiles sur les
combinaisons possibles. Toutes les combinaisons présentées ont été validées et
sont conformes aux exigences générales en matière de sécurité et de
performances énoncées dans annexe I No. 14.1 du règlement 2017/745 relatif aux
dispositifs médicaux.
Vous trouverez des conseils sur la combinaison, relatifs par exemple au
montage, sur www.sunrisemedical.fr.
54
Q700 M/M HD/F/R/UP-M/UP-F Rev.G
FRANÇAIS
2.0 Sécurité
Respectez toujours scrupuleusement les consignes apparaissant en regard des
symboles d’avertissement. Le non-respect des instructions peut causer des
blessures physiques, l’endommagement du fauteuil roulant ou la dégradation de
l’environnement. Dans la mesure du possible, les informations relatives à la
sécurité sont fournies dans le chapitre consacré à ce sujet.
2.1 Symboles et étiquettes apposés sur le produit
Les signes, symboles et instructions apposés sur le fauteuil roulant font
partie de l’ensemble des mesures de sécurité. Ils ne doivent jamais être
recouverts, ni retirés. Ils doivent rester en place et être clairement
lisibles tout au long de la durée de vie du fauteuil roulant. Tout signe,
symbole et instruction illisible ou endommagé doit être immédiatement remplacé
ou réparé. Pour toute assistance, contactez votre revendeur. Fig. 2.1.
Avertissement – Ne pas toucher – FORTE CHALEUR Fig. 2.2. Point d’arrimage Fig.
2.3. Avertissement – Risque de pincement des doigts Fig. 2.4. Avertissement
Vérifier que le verrou à libération rapide de l’interface
d’assise est bien serré avant d’utiliser le fauteuil, surtout en pente Fig.
2.5. Avertissement N’utilisez pas votre fauteuil en pente avec le dossier
incliné et/ou le siège en position verticale. Fig. 2.6. Avertissement La
charge maximale pour le fauteuil roulant : 160 kg Fig. 2.7. Avertissement La
charge maximale pour le fauteuil roulant : 205 kg Fig. 2.8. Mécanisme de roue
libre : levier externe vers le bas = roue libre Fig. 2.9. Étiquette de numéro
de série et plaque signalétique (exemple fourni ici). Fig. 2.10. Emplacement
de la plaque signalétique, (au verso – Fig. 2.10.1 roue
centrale, Fig. 2.10.2 roue traction (avant), 2.10.3 roue propulsion
(arrière)).
2.2 Sécurité : Température
AVERTISSEMENT !
· Évitez tout contact physique avec les moteurs du fauteuil roulant. Les
moteurs étant en mouvement permanent durant l’utilisation du fauteuil roulant,
ils peuvent atteindre des températures élevées. Une fois éteints, les moteurs
refroidissent lentement. Tout contact physique peut entraîner des brûlures.
Après utilisation du fauteuil, laissez les moteurs refroidir pendant au moins
30 min.
· Pendant la non-utilisation de votre fauteuil, évitez de le laisser exposer à
la lumière directe du soleil pendant des périodes prolongées. Certains
composants du fauteuil, comme le siège, le dossier et les accoudoirs peuvent
chauffer s’ils restent exposés au soleil pendant trop longtemps, risquant de
provoquer des brûlures ou des réactions allergiques cutanées.
· La surface du rembourrage du fauteuil (accoudoir et/ou appui-mollet) peut
devenir chaude ou froide selon les conditions ambiantes. Elle risque ainsi de
provoquer des brûlures, des lésions cutanées ou des réactions allergiques
cutanées.
Fig. 2.1
Fig. 2.2
Fig. 2.3
Fig. 2.4
Fig. 2.5
Fig. 2.6
MAX
160 kg
R
Fig. 2.7
MAX
205 kg
Fig. 2.8
TYPE: Q700 M
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-03-09 203204229996547
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7M20100330 max
kg
160 kg 350 kg 6 km/h max 6° 60kg/290kg/60kg
TYPE: Q700 F
kg
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
POWER WHEELCHAIR
2021-04-22 203204230017105
max
ISO 7176-19:2008
max max
kg
FIN-Nr: 7F20109639 max
kg
160 kg 385 kg 10 km/h max 6° 100kg/318kg
Fig. 2.9
Sunrise Medical GmbH Kahlbachring 2-4 D-69254 Malsch / Germany
2020-10-20
TYPE: Q700-UP M
POWER WHEELCHAIR ISO 7176-19:2008
203203729322630 FIN-Nr: 7UPM20960
max max max
max
kg
kg
kg
120 kg 350 kg 10 km/h max 6° 6