Qeo FL 220HV Rotating Laser Level User Manual

June 3, 2024
Qeo

FL 220HV Rotating Laser Level
User Manual

FL 220HV Rotating Laser Level

Dear customer,
Thank you for your confidence in us having purchased a geo-FENNEL instrument. This manual will help you to operate the instrument appropriately.
Please read the manual carefully – particularly the safety instructions. A proper use only guarantees a longtime and reliable operation.
geo-FENNEL Precision by tradition.
SUPPLIED WITH

  • Rotating Laser FL 220HV
  • Receiver FR 45 with clamp for levelling staff
  • Rechargeable battery and charger
  • Battery case for Alkaline batteries
  • Carrying case
  • User manual

CHARACTERISTICS

  • Working range up to 400 m Ø
  • Dust / water protection IP 54
  • Permanent 90° plumb beam
  • Automatic TILT alarm function
  • Auto-shut-off when out of level
  • Manual mode

Technical data

Self-levelling horizontal / vertical
Self-levelling range ± 5°
Laser class 2
Accuracy
 · horizontal ± 1,0 mm / 10 m
 · vertical ± 1,5 mm / 10 m
Working range with FR 45 Ø 400 m
Permanent 90° plumb beam yes
TILT mode yes
Manual mode yes
Rotating speed 600 rpm
Power supply / operating time 20 h (NiMH)
Temperature range -20°C – +50°C
Dust / water protection IP 54

POWER SUPPLY
Both the standard NiMH battery pack and Alkaline batteries can be used.

  1.  Insert Alkaline batteries into the Alkaline battery box (ensure correct polarity) and mount the battery box into the instrument.
    OR

  2. Mount the rechargeable battery box into the instrument.

CHARGING THE BATTERY
Connect the charger with the charging plug of the instrument and the power source. If the charging LED is red the battery is being charged; if the LED is green the battery is fully charged.
ATTENTION
The rechargeable battery can be charged if it is in the instrument or if it is ouside.
Battery status indication: If the ON/OFF LED flashes the battery has to be recharged.

FEATURES

1.  Laser emitting window 6. Support for vertical use
2. Rotating head 7.  5/8“ thread hole vertical
3. Handle 8. 5/8“ thread hole horizontal
4. Battery compartment 9. Charging plug
5. Keypad

OPERATION

HORIZONTAL USE
Set up the instrument on an even surface or mount it onto a tripod.
VERTICAL USE
Set up the instrument vertically (on the side with the vertical 5/8“ hole) or mount it onto a tripod with its vertical 5/8“ thread. HORIZONTAL USE
After powering on the unit a flashing laser diode indicates that the automatic self-levelling procedure is working. The laser starts rotating when it is self-levelled. If not the laser was set up outside of its selflevelling range. In this case set up the instrument on a more even surface.

1.  ON/OFF button 4. MANUAL LED
2. ON/OFF LED 5. TILT LED
3. MANUAL button 6. TILT button

POWER ON/OFF (1)
Power the laser on/off with button (1). If the red ON/OFF LED (2) is illuminated the laser is powered on. First the laser dot is flashing, then the self-levelling procedure starts automatically; meanwhile the TILT LED (5) is flashing. When the self-levelling procedure is completed the laser rotates with 600 rpm and the TILT LED (5) is illuminated permanently (= TILT function activated).
If in normal use the ON/OFF LED (1) flashes the battery has to be recharged.
TILT MODE (6)
After completion of the self-levelling procedure the TILT mode is automatically enabled.
If the level is now disturbed the rotation stops and the TILT LED is flashing.

  1. Press the TILT button (6) once: The rotation of the laser starts – but the TILT mode is disabled.
  2. Press the TILT button (6) twice: The rotation of the laser starts, the self-levelling procedure is completed and the laser restarts working with enabled TILT mode.
    Press button (6) to disable the TILT mode after completion of the self- levelling procedure.

MANUAL MODE (3)
Power on the laser with button (1). After completion of the self-levelling procedure press button (3). The TILT LED (5) will power off and the MANUAL LED (4) will be illuminated permanently. Now the laser can be used in slope position, i. e. it can be used with a grade mount without giving TILT alarm.
In vertical position a required alignment can be made quick and safe by means of the MAN function. When the alignment has been made quit the MAN function.
APPLICATION

RECEIVER FR 45

FEATURES

1.  Vial (2) 7.  Battery compartment (back side)
2. Display 8. Sound on / off
3. Reference indicator 9. Accuracy coarse / normal / fine
4. Receiving window 10. Light on / off
5. ON / OFF switch 11.  Magnets (2)
6. Loudspeaker 12. 1/4“-thread for clamp (back side)

SUPPLIED WITH
Receiver FR 45, battery, clamp, user manual
Technical Data

Indication Front display
Accuracy coarse ± 10 mm
Accuracy normal ± 4 mm
Accuracy fine ± 2 mm
Tones 3
Operating time 400h
Power supply 1 x 9V

SYMBOLS

  1. Power ON / OFF
  2. Battery status indicator
  3. Detection indicator
  4. Sound ON / OFF
  5. Detected position indicator

ACCURACY COARSE / NORMAL / FINE
The FR 45 is equipped with three precision modes. They can be chosen by pressing button (9):

Accuracy coarse ± 10 mm
Symbol on display: without symbol
Accuracy normal ± 4 mm
Symbol on display:
Accuracy fine ± 2 mm
Symbol on display:

INSTALLATION OF THE BATTERIES

  • Open the battery compartment cover (7).
  • Insert 1 x 9 V AA battery according to the installation symbol (ensure correct polarity!). Close the cover.
  • In order to save battery power the receiver will automatically turn off if it has not received laser scanning singal for 5 minutes.

USE OF RECEIVER
Press the button (5) to switch the unit on.
Move the receiver up and down carefully to detect the laser beam.
A Move the receiver down Acoustic signal : ultra-short requent beep
B Move the receiver up Acoustic signal: short requent beep
C On level Acoustic signal: continuous beep
A+B: The closer the distance to „on level“ (C) is, the shorter the arrows become.
CLAMP FOR LEVELLING STAFF
If required the FR 45 can be attached to laser poles or any other equipment by means of the clamp supplied with.

SAFETY NOTES

SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS
Measurements through glass or plastic windows; dirty laser emitting windows; after the instrument has been dropped or hit. Please check the accuracy.
Large fluctuation of temperature: If the instrument will be used in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out measurements.
CARE AND CLEANING
Handle measuring instruments with care. Clean with soft cloth only after any use. If necessary damp the cloth with some water. If the instrument is wet clean and dry it carefully. Pack it up only if it is perfectly dry. Transport in original container / case only.
ELECTROMAGNETIC ACCEPTABILITY (EMC)
It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems); will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial facilities or radio transmitters). CE-Conformity
The instrument has the CE mark according to EN 61010-1:2001 + corrig. 1+2.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufacturers option), without charge for either parts or labour. In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused or altered. Without limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY

  1.  The user of this product is expected to follow the instructions given in the user manual. Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance.
  2. The manufacturer, or its representatives, assumes no responsibility of results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
  3. The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
  4. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to ‘a change of data, loss of data and interruption of business etc., caused by using the product or an unusable product.
  5. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than explained in the user manual.
  6. The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connecting with other products.

INTENDED USE OF INSTRUMENT
The instrument emits a visible laser beam in order to carry out the following measuring tasks (depending on the instru- ment): Setting up heights, horizontal and vertical planes, right angles.

SAFETY INSTRUCTIONS

Follow up the instructions given in the user manual.

  • Do not stare into the beam. The laser beam can lead to eye injury. A direct look into the beam (even from greater distance) can cause damage to your eyes.
  • Do not aim the laser beam at persons or animals.
  • The laser plane should be set up above the eye level of persons.
  • Use the instrument for measuring jobs only.
  • Do not open the instrument housing. Repairs should be carried out by authorized workshops only. Please contact your local dealer.
  • Do not remove warning labels or safety instructions.
  • Keep the instrument away from children.
  • Do not use the instrument in explosive environment.
  • The user manual must always be kept with the instrument.

LASER CLASSIFICATION
The instrument is a laser class 2 laser product according to DIN IEC 60825-1:2014. It is allowed to use the unit without further safety precautions.
The eye protection is normally secured by aversion responses and the blink reflex. The laser instrument is marked with class 2 warning labels. Please note:
If you return instruments for repair / for adjustment to us please disconnect batteries or rechargeable batteries from the instrument – this is for safety reasons! Thank you.

www.geo-fennel.de
www.geo-fennel.com
www.geo-fennel.fr
geo-FENNEL GmbH
Kupferstraße 6
D-34225 Baunatal
Tel. +49 561 / 49 21 45
Fax +49 561 / 49 72 34
info@geo-fennel.de
www.geo-fennel.de
All instruments subject to technical changes.


10/2019
Precision by tradition.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals