GM Lighting LTR-S-HO Series 8W High Output LED Tape
WARNING!
FAMILIARIZE YOURSELF WITH INSTRUCTIONS BEFORE PROCEEDING. USE ONLY GM LIGHTING
LineDRIVE 24VDC DRIVERS TO ACTIVATE 5-YEAR WARRANTY. FOLLOW ALL LOCAL CODES.
VERIFY THAT POWER IS OFF BEFORE PROCEEDING.
SPECIFICATION
NOTE: WE RECOMMEND THAT YOU ENGAGE A QUALIFIED AND LICENSED ELECTRICIAN. ALL SYSTEM PARTS ARE COMPATIBLE WITH AND ONLY WORK TOGETHER. DO NOT ATTEMPT TO SWAP OUT OTHER MANUFACTURERS PRODUCTS. INSURE THAT BOTH WALL SWITCH AND LED DRIVER IS GROUNDED IN ACCORDANCE WITH NEC OR LOCAL ELECTRICAL CODES.
DO NOT INSTALL IN AN APPLICATION THAT IS OUTSIDE OF THE PRODUCTS LISTED AMBIENT TEMPERATURE AND IN AN AREA THAT IS NOT EASILY ACCESSED FOR SERVICE REQUIREMENTS. DOWN LIGHT IS IC RATED.
LAYOUT and PRE-CONFIGURE COMPONENTS
LTR-S-HO tape requires that it be installed in a GM Lighting mounting channel for thermal management and heat dissipa-tion. Prepare surface that channels and power supply will be mounted on by making sure surface is free of dust or lint. Use proper household or commercial cleaner, depending on surface FIG. 1.
CONNECTING TAPE TO POWER
Connect leads provided on beginning of tape to 24V LineDRIVE power supply (in order to validate 5-year warranty). Consult power supply instructions on proper method of connection.
CUTTING TAPE
Cut tape to size only by cutting on the cut marks. Cutting anywhere else on the tape will render your application useless FIG 2.
JOINING TAPE SECTIONS TOGETHER
Joining tape sections together reliably requires that you use either GM
Lighting SureTight or EZ Connectors. Expose bottom of tape by peeling back a
small amount of adhesive FIG 3.
Insert end of tape into connector and if you are using a Sure-Tight, tighten
screws carefully FIG 4. If you are using an EZ Connector, capture end of tape
in open mouth of connector, and then close until you hear an audible click FIG
5.
MOUNTING CHANNELS
Lay mounting channels on prepared surface and screw into place FIG 6. Lay tape into channel using adhesive backing to secure (remove red protective paper tape to expose adhesive). Burnish with your finger or a wooden stick to form a tight adhesive seal. Use channel lens if one is supplied.
18700 Ridgeland Ave., Tinley Park, IL 60477 Toll-Free: 866-671-0811 • FAX: 708-478-2640