KERN EW-N/EG-N Precision Scales User Guide
- June 9, 2024
- KERN
Table of Contents
**KERN EW-N/EG-N Precision Scales User Guide
**
Features
- 1 KERN EG-N: Internal adjustment in the case of a change in temperature and time-controlled at defined intervals, guarantees high degree of accuracy and makes the balance independent of its location of use
- KERN EW-N: Adjusting program CAL for quick setting of the balance accuracy using an external test weight at an additional price, see test weights
- Stable temperature behaviour
- Short stabilisation time
- Shock proof construction
- High corner load performance
- Capacity display: A bargraph display lights up to show how much of the weighing range is still available
- GLP/ISO record keeping of weight values
- Totalising of pieces when counting
- Draught shield standard for models with weighing plate size A , weighing space W×D×H 158×130×78 mm
- Protective working cover included with delivery
Technical data
-
Large LCD display, digit height 17 mm
-
Dimensions weighing surface
A ∅ 118 mm, stainless steel, see larger picture
B W×D 170×140 mm, stainless steel
C W×D 180×160 mm, stainless steel -
Overall dimensions W×D×H (without draught shield) A, B 182×235×65 mm, C 265×192×87 mm
-
Net weight A, B approx. 2,0 kg, C approx. 4,0 kg
-
Permissible ambient temperature 10°C/30°C
Accessories
- Protective working cover, scope of delivery: 5 items, for models with weighing plate size A, B KERN EG-A05S05 C KERN EG-A09S05
- Internal rechargeable battery pack, operating time up to 32 h without backlight, charging time approx. 12 h, for models with weighing plate size A, B KERN EG-A04 C KERN EG-A06
- Large glass draught shield with 3 sliding doors for easy access to the items being weighed. Weighing space W×D×H 150×140×130 mm, KERN EG-A03
- Loop for underfloor weighing, for models with weighing plate size A, B KERN EG-A07 C KERN EG-A08
- Minimum weight of sample, smallest weight to be weighed, depending on the required process accuracy, only in combination with a DAkkS calibration certificate, KERN 969-103
- Equipment qualification: compliant qualification concept which includes the following validation services, Installation Qualification (IQ), Operating Qualification (OQ)
- Further details, plenty of further accessories and suitable printers see Accessories
STANDARD
OPTION
FACTORY
KERN | g | g | g | g | g | KERN KERN |
---|---|---|---|---|---|---|
EW 220-3NM | 220 | 0,001 | – | – | ± 0,002 | A – |
963-127
EW 420-3NM| 420| 0,001| –| –| ± 0,003| A –
963-127
EW 620-3NM| 620| 0,001| –| –| ± 0,003| A –
963-103
EW 820-2NM| 820| 0,01| –| –| ± 0,01| B –
963-127
EW 2200-2NM| 2200| 0,01| –| –| ± 0,01| C –
963-127
EW 4200-2NM| 4200| 0,01| –| –| ± 0,02| C –
963-127
EW 6200-2NM| 6200| 0,01| –| –| ± 0,03| C –
963-104
EW 12000-1NM| 12000| 0,1| –| –| ± 0,2| C –
963-128
Note: For applications that require verification, please order verificati on
at the same time, initial verification at a later date is not
possible.Verification at the factory, we need to know the full address of the
location of use.
EG 220-3NM| 220| 0,001 0,01| 0,02 ± 0,002| A|
965-216| 963-127
EG 420-3NM| 420| 0,001 0,01| 0,02 ± 0,003| A|
965-216| 963-127
EG 620-3NM| 620| 0,001 0,01| 0,1 ± 0,004| A|
965-201| 963-103
EG 2200-2NM| 2200| 0,01 0,1| 0,5 ± 0,01| C|
965-216| 963-127
EG 4200-2NM| 4200| 0,01 0,1| 0,5 ± 0,02| C|
965-216| 963-127
Internal adjusting:
Quick setting up of the balance‘s accuracy with internal adjusting weight
(motordriven)
Adjusting program CAL:
For quick setting up of the balance‘s accuracy. External adjusting weight
required
Easy Touch:
Suitable for the connection, data transmission and control through PC or
tablet.
Memory:
Balance memory capacity, e.g. for article data, weighing data, tare weights,
PLU etc.
Alibi memory:
Secure, electronic archiving of weighing results, complying with the
2014/31/EU standard
KERN Universal Port (KUP ) :
allows the connection of external KUP interface adapters, e.g. RS-232, RS-485,
SB, Bluetooth, WLAN, Analogue, Ethernet etc. for the exchange of data and
control commands, without installation effort
Piece counting:
Reference quantities selectable. Display can be switched from piece to weight
Integrated power supply unit: Integrated in balance. 230V/50Hz standard EU.
More standards e.g. GB, USA or AUS on request
Data interface RS-232:
To connect the balance to a printer, PC or network
Recipe level A:
The weights of the recipe ingredients can be added together and the total
weight of the recipe can be printed out
Weighing principle:
Strain gauges Electrical resistor on an elastic deforming body
RS-485 data interface:
To connect the balance to a printer, PC or other peripherals. Suitable for
data transfer over large distances. Network in bus topology is possible
Recipe level B:
Internal memory for complete recipes with name and target value of the recipe
ingredients. User guidance through display
Weighing principle: Tuning fork
A resonating body is electromagnetically excited, causing it to oscillate
USB data interface:
To connect the balance to a printer, PC or other peripherals
Totalising level A:
The weights of similar items can be added together and the total can be
printed out
Weighing principle:
Electromagnetic force compensation Coil inside a permanent magnet. For the
most accurate weighings
*Bluetooth data interface:**
To transfer data from the balance to a printer, PC or other peripherals
Percentage determination:
Determining the deviation in % from the target value (100 % )
Weighing principle: Single cell technology:
Advanced version of the force compensation principle with the highest level of
precision
WiFi data interface:
To transfer data from the balance to a printer, PC or other peripherals
Weighing units:
Can be switched to e.g. nonmetric units. See balance model. Please refer to
KERN‘s website for more details
Verification possible:
The time required for verification is specified in the pictogram
Control outputs (optocoupler, digital I/O) :
To connect relays, signal lamps, valves, etc. Weighing with tolerance range:
(Checkweighing) Upper and lower limiting can be programmed individually, e.g.
for sorting and dosing. The process is supported by an audible or visual
signal, see the relevant model DAkkS calibration possible (DKD ) : The time
required for DAkkS calibration is shown in days in the pictogram
Analogue interface:
to connect a suitable peripheral device for analogue processing of the
measurements Factory calibration (ISO ): The time required for Factory
calibration Hold function: is shown in days in the pictogram (Animal weighing
program) When the weighing conditions are un stable, a stable weight is
calculated as an average value Interface for second balance: For direct
connection of a second balance
Package shipment:
The time required for internal shipping prepa rations is shown in days in the
pictogram Protection against dust and water splashes IPxx: The type of
protection is shown in the
pictogram. Pallet shipment:
The time required for internal shipping prepa rations is shown in days in the
pictogram
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>