KERN TEE-BA-e-1812 Electronic Pocket Balance Instruction Manual
- October 30, 2023
- KERN
Table of Contents
KERN TEE-BA-e-1812 Electronic Pocket Balance
Product Information
- Product Name: KERN TEE Electronic Pocket Balance
- Manufacturer: KERN & Sohn GmbH
- Address: Ziegelei 1 D-72336 Balingen
- Contact Information: E-Mail: info@kern-sohn.com, Tel.: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149, Internet: www.kern-sohn.com
- Model Number: TEE-BA-e-1812
- Version: 1.2
- Year: 2018
- Country of Origin: Germany
Technical Data:
- Weighing Range (Max): [insert maximum weight]
- Readout (d): [insert readout value]
- Operating Conditions: [insert operating conditions information]
Package Volume:
[Insert package volume information]
Adjustment:
[Insert adjustment process information]
Important Notes:
- [Insert important notes information]
Declaration of Conformity:
To view the current EC/EU Declaration of Conformity, go to www.kern-
sohn.com/ce
KERN & Sohn GmbH
Ziegelei 1
D- 72336 Balingen
E- Mail: info@kern-sohn.com
Tel.: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
internet: www.kern-sohn.com
Product Usage Instructions
- Place the electronic pocket balance on a flat and stable surface.
- Press the ON/OFF button to turn on the balance.
- Wait for the display to show zero or the tare weight.
- Place the item to be weighed onto the balance.
- The weight will be displayed on the screen.
- Remove the item from the balance and turn off the device after use.
- If recalibration is needed, follow the adjustment process as outlined in the user manual.
Technical Data
- Weighing range (Max): 150 g
- Readout (d): 0.1 g
- operating conditions: 18 – 25 °C max. 85% air humidity (not condensing)
- power supply: 2 x 1,5V „AAA“
Operation
- Press the “ON” – key, the balance displays “8.8.8.8” and switches to “0.0 g”.
- Place the weighing object in the middle of the weighing platform; the weight in grams is shown on the display.
- By pressing “ZERO” the balance can be reset to “0.0 g”.
- Weighing unit switch-over: from g to OZ (button under balance)
Package Volume
- Pocket Balance
- Balance cover
- Batteries (2 x 1,5V „AAA“)
- Operating instructions
Adjustment
- By pressing “CAL” for 3 seconds until “CAL” appears on the display.
- Let loose the “CAL”-key; the display shows “100”.
- Place recommended adjusting weight (100 g, class M3, not included). Information concerning the adjusting weights is available at: http://www.kern-sohn.com
- The display switches to “F” and the adjustment is complete.
- If other messages are on the display, the adjustment was faulty.
Please repeat the adjustment process.
Important Notes
- Do not overload the balance (when overloaded, error message “E” appears)
- With the occurrence of electromagnetic fields deviations of the displayed weight value are possible. In case of deviations change location.
- Avoid high air humidity, vapours and dust, because the balance is not hermetically closed. Do not bring the balance in direct contact with liquids. Liquids could enter the load cell.
- No permanent load on the weighing platform.
- Never operate the balance in rooms where danger of explosion exists.
- Regularly check the balance with the test weight.
- Warranty expires as soon as the balance is opened.
Declaration of Conformity
To view the current EC/EU Declaration of Conformity go to: www.kern- sohn.com/ce
References
- Your Name as Your Email | Hover Realnames
- KERN & SOHN: Waagen, Mikroskope & Messinstrumente
- KERN & SOHN: Waagen, Mikroskope & Messinstrumente
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>