cell2 ID26 Mini Light Head Instruction Manual
- June 9, 2024
- Cell2
Table of Contents
ID26 Mini Light Head
Instruction Manual 170221M41-2
ID26 Mini Light Head
Surface Mount
NOTE: RED wire has priority over WHITE wire when both wires are activated.
Operation
This lightheaded is designed with 2 sets of memory to allow instant switch between 2 pre-set flash patterns with a simple switch of a button (user- supplied). Connect BLACK wire to Ground, and apply +VDC to WHITE wire to activate Memory1 or to RED wire to activate Memory2.
Step 1
Select Function & Flash Pattern
a. Activate Memory1 by applying +VDC to WHITE wire.
b. While WHITE wire is activated, momentarily apply +VDC to YELLOW wire:
• once for <1 second for next flash pattern.
• quickly three times for reset to default.
Function | FP# | Flash Pattern |
---|---|---|
Warning | 1 | Double (default) |
2 | Single | 2Hz |
3 | Triple | 2Hz |
4 | Quad | 2Hz |
5 | Random | – |
6 | Single | SAE |
7 | Double | SAE |
8 | Quad | SAE |
9 | Quint | SAE |
10 | Mega | – |
11 | Ultra | SAE |
12 | Single-Quad | – |
13 | Single H/L | – |
Steady & Warning | 14 | Steady& Warning |
Full Steady | 15 | Full Steady |
Step 2
Select Mode
a. While WHITE wire is activated, apply +VDC to YELLOW wire for >3 seconds
to enter Mode setting.
b. Once in Mode setting, lightheaded will display dim slow pulses based on its
Mode and Group (single or double pulses respectively).
c. Momentarily apply +VDC to YELLOW wire for <1 second for next Mode.
(refer to Mode charts).
d. Momentarily apply +VDC to YELLOW wire quickly 3 times within 1 second
to reset to Mode1.
e. When desired mode is selected, apply +VDC to YELLOW for >3 seconds or
disconnect all power to exit Mode setting.
f. To configure Memory2, apply +VDC to RED wire and repeat the above steps A &
B.
NOTE:
For multiple lightheaded installation, heads in the same Group flash together.
[G1] Heads alternate with [G2] Heads. For synchronization all YELLOW wires
must be connected together, and set at the same Flash Pattern.
Mode | Warning Effect | |
---|---|---|
1 | All (single pulse) | All [G1] |
2 | All (double pulse) | All [G2] |
3 | Split (single pulse) | Split [G1] |
4 | Split (double pulse) | Split [G2] |
5 | Top (single pulse) | Top only [G1] |
6 | Top (double pulse) | Top only [G2] |
7 | Bottom (single pulse) | Bottom only [G1] |
8 | Bottom (double pulse) | Bottom only [G2] |
All = Top & Bottom simultaneous
Split = Top & Bottom alternating
[G1] = Group1 [G2] = Group2
| Mode| Steady & Warning Effect
---|---|---
1| All (single pulse)| Top Steady & Bottom Double Flash [G1]
2| All (double pulse)| Top Steady & Bottom Double Flash [G2]
3| Split (single pulse)| Bottom Steady & Top Double Flash [G1]
4| Split (double pulse)| Bottom Steady & Top Double Flash [G2]
5| Top (single pulse)| Top Steady & Bottom Quad Flash [G1]
6| Top (double pulse)| Top Steady & Bottom Quad Flash [G2]
7| Bottom (single pulse)| Bottom Steady & Top Quad Flash [G1]
8| Bottom (double pulse)| Bottom Steady & Top Quad Flash [G2]
[G1] = Group1 [G2] = Group2
All = Top & Bottom simultaneous
Split = Top & Bottom alternating
| Mode| Full Steady Effect
---|---|---
1| All (single pulse)| All high power
2| All (double pulse)| All low power
3| Split (single pulse)| All high power
4| Split (double pulse)| All low power
5| Top (single pulse)| Top high power
6| Top (double pulse)| Top low power
7| Bottom (single pulse)| Bottom high power
8| Bottom (double pulse)| Bottom low power
All = Top & Bottom simultaneous
Split = Top & Bottom alternating
Examples
Example Configuration#1:
I would like Memory1 to be Full Steady (All low power), and Memory2 to be
split Ultra flash (Top row LEDs alternate Bottom row LEDs).
- Activate WHITE wire and select FP#15.
- Enter Mode setting and select Mode#2.
- Activate RED wire and select FP#11.
- Enter Mode setting and select Mode#3 (or Mode#4).
Example Configuration#2:
I would like Memory1 to be Top Steady & Bottom Double Flash, and Memory2 to be
All Ultra flash.
- Activate WHITE wire and select FP#14.
- Enter Mode setting and select Mode#1 (or Mode#2).
- Activate RED wire and select FP#11.
- Enter Mode setting and select Mode#1 (or Mode#2).
[G1] = Group1 [G2] = Group2