Cell2 MSP15HM Dual Level Multi Function Warning Light User Manual
- May 15, 2024
- Cell2
Table of Contents
Cell2 MSP15HM Dual Level Multi Function Warning Light
Specifications
- Product Name: Dual Level Multi-Function Warning Light
- Model Number: 86-M08810-0101.0
- Color Modes: Single, Dual, Tri-Color
- Flash Patterns: Various options are available
- Wiring: Black to Chassis ground, Yellow for Setting, Synchronisation, and Flash Pattern
Product Usage Instructions
Wiring Instructions
- Connect the BLACK wire to the Chassis ground.
- For synchronizing and flash pattern settings, connect all YELLOW wires of light heads together.
Operation Flash Pattern Selection: To select and save a flash pattern, apply the YELLOW wire to +VDC momentarily while activating a warning mode
Shortcut Setting for Steady EF (External flasher)
- Apply YELLOW wires to +VDC for more than 4 seconds during any warning mode activation to change trigger wires to default colour mode and Steady EF pattern.
Colour & Pattern Selection
- Refer to the Color and Pattern charts for different modes and available patterns based on the colour model selected (Single, Dual, Tri-Color).
Wiring
NOTE
- [+] = Activate the wire function by applying constant +VDC to the wire.
- [Px] = Precedence order, when more than one wire is activated at the same time, higher precedence wire will affect the lower precedence wire. P1 being the highest priority.
Operation
- For Flash Pattern Selection:
- Each Warning mode may select and save one flash pattern. While activating a warning mode, momentarily apply
- YELLOW wire to +VDC:
- once to the next pattern.
- quickly three times to FP#1.
Default Setting Chart
COLOUR & PATTERN | Single Colour Model |
---|---|
Default Colour | Default Pattern |
Mode 1 | Colour1 |
Mode 2 | Colour1 |
Mode 3 | Colour1 |
Mode 4 | Colour1 |
Mode 5 | Colour1 |
COLOUR & PATTERN | Dual Colour Model |
--- | --- |
Default Colour | Default Pattern |
Mode 1 | Colour1 |
Mode 2 | Colour1 |
Mode 3 | Colour1 |
Mode 4 | Colour2 |
Mode 5 | Colour2 |
COLOUR & PATTERN | Tri Colour Model |
--- | --- |
Default Colour | Default Pattern |
Mode 1 | Colour1 |
Mode 2 | Colour1 |
Mode 3 | Colour2 |
Mode 4 | Colour3 |
Mode 5 | Colour2 |
Shortcut Setting for Steady EF (External flasher)
This shortcut allow changing all trigger wires to its default color mode and
Steady EF pattern at the same time.
While activating any warning mode, momentarily apply YELLOW wires to +VDC for
more than 4 seconds.
(Visual feedback ON→OFF→ON)
FP#| Flash Pattern| Available Colour
Mode
| Remark| FP#| Flash Pattern| Available Colour
Mode
| Remark
---|---|---|---|---|---|---|---
1| Double [2HZ]| S / D / T| | 25| Steady Mid| S / D / T|
2| Single [2HZ]| S / D / T| | 26| MINI TA RIGHT| S / D / T|
3| Triple [2HZ]| S / D / T| | 27| MINI TA RIGHT SOLID| S / D / T|
4| Quad [2HZ]| S / D / T| | 28| MINI TA RIGHT SWEEP – Left Side of a pair| S
/ D / T| When using as a pair of units
5| Random| S / D / T| | 29| MINI TA RIGHT SOLID – Left Side of a pair| S / D
/ T| When using as a pair of units
6| Steady EF| S / D / T| For use with an external flash controller| 30| MINI
TA RIGHT SWEEP – Right Side of a pair| S / D / T| When using as a pair of
units
7| Single [SAE/CA13]| S / D / T| | 31| MINI TA RIGHT SOLID – Right Side of a
pair| S / D / T| When using as a pair of units
8| Double [SAE]| S / D / T| | 32| Steady Low| S / D / T|
9| Triple [SAE]| S / D / T| | 33| MINI TA CENTER-OUT| S / D / T|
10| Quad [SAE]| S / D / T| | 34| MINI TA CENTER-OUT SOLID| S / D / T|
11| Quint [SAE]| S / D / T| | 35| Steady Cruise| S / D / T|
12| Mega| S / D / T| | 36| Sweep Single TA| S / D / T|
13| Giga| S / D / T| | 37| Turn Indicator [ECE Amber / SAE Red]| S / D / T|
For use with an Intermittent flash signal with OFF delay
14| Ultra [SAE]| S / D / T| | 38| Turn Indicator [SAE Amber]| S / D / T| For
use with an Intermittent flash signal with OFF delay
15| Single-Quad| S / D / T| | 39| OFF| S / D / T|
16| Single H/L| S / D / T| | 40| Single-Single| D|
17| Single-Triple-Quint| S / D / T| | 41| Double-Double| D|
18| Steady High| S / D / T| | 42| Triple-Triple Mid| D|
19| MINI TA LEFT SWEEP| S / D / T| | 43| Triple-Triple Fast| D|
20| MINI TA LEFT SOLID| S / D / T| | 44| Quint-Triple| D|
21| MINI TA LEFT SWEEP – Left Side of a pair| S / D / T| When using as a pair
of units| 45| 7-1 Flash| D|
22| MINI TA LEFT SOLID – Left Side of a pair| S / D / T| When using as a pair
of units| 46| Quad-Single| D|
23| MINI TA LEFT SWEEP – Right Side of a pair| S / D / T| When using as a pair
of units| 47| Quint-Quint| D|
24| MINI TA LEFT SOLID – Right Side of a pair| S / D / T| When using as a pair
of units|
S = Single Colour D = Dual Colour T = Tri Colour
Setting Mode
- Each Warning mode may select and save its Colour Mode and Flash Group. Power down the unit then apply +VDC to a Warning Mode function wire
- (RED or ORANGE or RED&ORANGE or GREEN or BLUE) and YELLOW wires simultaneously then remove YELLOW wire to enter SETTING
- MODE for the following settings. Save and exit the setting by disconnecting the power.
- For Colour Mode Setting:
- Momentarily apply the YELLOW wire to +VDC for less than 1 seconds to change colour and order. Please refer to the Colour Mode table.
- NOTE: For Single and Dual Colour Models, only limited modes are available.
- For Simultaneous or Alternating Synchronisation:
- To change Group, momentarily apply YELLOW wire to +VDC for more than 3 seconds. Display of the lighthead:
- Single flash = Group 1 (Simultaneously) • Double flash = Group 2 (Alternately)
- NOTE: Lightheads of the same Group will flash together; lightheads of the Group 1 & Group 2 will flash alternately.
- Reset to Factory Default Settings:
- Apply to +VDC for more than 5 seconds. The lighthead will display fast short flashes to signify restoring successfully.
Warning Mode 5 Setting
By default, BLUE wire functions as Low Power operation. However, it is
possible to set BLUE wire function as an extra Warning Mode 5. To config,
power down the unit, apply +VDC to a wire and YELLOW wires simultaneously then
remove YELLOW wire to enter WARNING MODE 5 SETTING MODE. Momentarily apply
YELLOW wire to +VDC for less than 1 second to change its setting. Once set,
exit the setting by disconnecting the power.
- Steady Low = Low Power Operation (Default)
- Steady High = Warning Mode 5.
Dimensions
L-Bracket Mount
Surface Mount
Bail (U-Bracket) Mount
Surface Mount Template
Documents / Resources
|
Cell2 MSP15HM Dual Level Multi Function Warning
Light
[pdf] User Manual
MSP15HM Dual Level Multi Function Warning Light, MSP15HM, Dual Level Multi
Function Warning Light, Multi Function Warning Light, Function Warning Light,
Warning Light
---|---
Read User Manual Online (PDF format)