ULINE Industrial Platform Scale User Manual

June 7, 2024
ULINE

ULINE - logo

H-670, H-747
H-794, H-4593
INDUSTRIAL PLATFORM SCALE

1-800 -295-5510
uline.com

ULINE Industrial Platform Scale r

TOOLS NEEDEDULINE Industrial Platform Scale TOOLS
NEEDED

PARTS

ULINE Industrial Platform Scale PARTS

ASSEMBLY

  1.  Remove scale parts from packaging.
  2. Lift the scale pan off the platform base.
  3. Remove the four styrofoam blocks from the platform base. (See Figure 1)
  4.  Replace the scale pan.ULINE Industrial Platform Scale Figure 1
  5. Place the scale on the stable, level surface on which it is intended to be used.
  6. Using the bubble level on the base bracket as a guide, adjust the four leveling feet until the scale is level.  (See Figure 2)ULINE Industrial Platform Scale Figure 2
  7. Feed the data cable from the base bracket through the tower. (See Figure 3)ULINE Industrial Platform Scale Figure 3
  8. Tighten the set screws in the base bracket using the included Allen wrench. (See Figure 4)ULINE Industrial Platform Scale Figure 4
  9. Feed the data cable through the support bracket by unscrewing the knob and pulling the support bracket pieces apart. (See Figure 5)
  10.  Once the data cable is threaded through the support bracket as shown, tighten the knob and place the support bracket on the tower. (See Figure 5)ULINE Industrial Platform Scale Figure 5
  11. Tighten the bolt at the base of the support bracket using a 10 mm box wrench.
  12.  Slide the display Indicator onto the support bracket. Adjust the angle of the display by loosening the knob on the support bracket. Tighten the knob when finished adjusting the angle. (See Figure 6)ULINE Industrial Platform Scale Figure 6
  13. Plug the data cable and the AC adapter into the display indicator. (See Figure 7)ULINE Industrial Platform Scale Figure 7

QUICK USER’S GUIDE

COUNTING FUNCTION
• Prior to using, connect the AC adapter and monitor cable.
• This scale has fixed samples of 10, 20, 50, and 100 pieces.
• The larger sample sizes will provide you with more accurate unit weight.

  1. Prior to placing any object onto the scale, press the CE  key (1). (See Figure 8)
  2. Select the fixed sample key of 10, 20, 50, 100 pieces (2).  (See Figure 8)
  3. Place the requested number of samples onto the scale.
  4.  Press the COUNT key (4).(See Figure 8)
  5. Remove all parts from the scale.
  6. Place the desired number of pieces onto the scale. This will provide an accurate count reading.
  7. Remove all parts from the scale.
  8. For the H-670 and H-4593: Press the UNITS key (8) to return to the weight display screen. (See Figure8)
  9.  For the H-747 and H-794: Press the Kg key (8) to return to the weight display screen. (See Figure 8)

ULINE Industrial Platform Scale QUICK USER'S GUIDEULINE Industrial Platform Scale For the H-670
2

CALIBRATION INSTRUCTIONS

NOTE: Scale can only be accurately calibrated using standard calibrated scale weights. Using non-calibrated weights may result in inaccurate scale calibration. Nothing should be on the scale and scale should be level.

ACTIVATE WEIGHT CALIBRATION MODE

Switch the mini jumper SWA1 to the “ADJ” position. Adjust is down; Lock is up. The switch is located under a panel on the right side of the keypad housing.

Turn on the scale. As scale counts down to zero, press and holds the ZERO key until the software version (ex: 02018 ) appears on the display.
Release ZERO key. F 0 appears in the display.

Press ENTER key. Display shows .
Press ENTER key. Display shows
Press UNITS or Kg key to set scale to lb or kg as needed.

Press UNITS or Kg key to set scale to lb or kg as needed.

Use the UP and ENTER keys to preset the weight being used to calibrate the scale. The UP key sets the
number and the ENTER key moves right one digit.
Example: To set a weight of 3.0 kg, you would press the ENTER key three times to move right three
spaces and the UP key three times to enter the number 3.

  •  Place your calibrated weight on the scale.
  • Press ENTER key. Display shows .
  •  Scale displays weight and beeps.
  •  Scale is calibrated, it will now return to weighing mode automatically.
  •  Switch the mini jumper SWA1 back to “LOCK.”

ULINE - logo

1-800-295-5510
uline.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals