Cell2 SW833 8+2 Outputs Control Panel User Manual
- June 9, 2024
- Cell2
Table of Contents
Cell2 SW833 8+2 Outputs Control Panel
Warning & Precautions
NOTICE TO INSTALLER
Before installation and operation – read all instructions, warnings and
precautions thoroughly and carefully.
Deliver this manual to the end user of this product
- Failure to follow these instructions could result in serious damage to the unit or vehicle and may void warranties.
- Proper installation of the product requires the installer to have a good understanding of automotive electronics, systems and procedures. It is essential to install the unit properly to ensure safe and reliable operation.
- Do not install this product or route any wires in the air bag deployment zone of your vehicle. Equipment mounted or located in air bag deployment zones will damage or reduce the effectiveness of the air bag, or become a projectile that could cause serious personal injury or death. Refer to your vehicle owner’s manual to learn the air bag deployment zones for the vehicle.
- A properly-rated fuse must be installed as close to the battery as possible to protect the wires.
- The same applies to any devices controlled by the installed device.
- Ensure that none of the vehicle’s original controls will be affected by the installed device.
- Ensure that any unit is located in an area that allows both the vehicle and the control panel to be operated safely in any driving condition.
Contents & Specs
- Power Module x 1 pc
- Controller x 1 pc
- RJ45 Cable (4m) x 1 pc
- Terminal Block x 1 pc
- Self-drilling Screw (#8 x 1″) x 4 pcs
- 6-Pin Wire Harness x 1 pc
- Adjustable Bracket (based on the model ordered)
- Suction Cup Bracket x 1 pc
- Suction Base x 1 pc
- Screw Mount Bracket x 1 pc
- Self-drilling Screw (Ø4 x 15mm) x 2 pcs
- Decals x 1 set
- Manual x 1 pc
Specifications
Controller
- Operating Voltage: 10~30VDC
- Operating Temperature: -40°C~60°C
- Dimensions: 68.8mm x 95mm x 25.5mm
Power Module
- Number of Positive Outputs: 8
- Number of Negative Outputs: 2
- Max Current / Positive Outputs: 1x 15A, 2x 10A, 1x 10A (for Output 4~8)
- Max Current / Negative Outputs: 2x 2A
- Fuse Rating: 50A (user-supplied)
- Dimensions: 100.5mm x 91.6mm x 25mm
Mounting
Screw Mount Bracket
- Choose a desired place for installation.
- Use the base as the template to locate and mark two mounting holes on the mounting surface.
- Secure the bracket with the two Ø4 self-drilling screws supplied.
- Assemble the controller with the bracket by tightening the knurled knob in a firm way.
- Adjust the bracket at an angle most convenient to your operation
Suction Cup Bracket
- Choose a desired place for installation.
- Press the suction cup to install the controller on the windshield directly. Or assemble the adhesive base at the bottom of the suction cup and follow the instructions below.
- Mount the suction cup onto the mounting surface and allow the adhesive to set for at least 24 hours.
- Assemble the controller on the bracket by tightening the knurled knob in a firm way.
- Adjust the bracket at an angle most convenient to your operation.
Power Module
- Choose a flat surface to install the power module.
- Use the power module as the template to locate and mark four mounting holes on the mounting surface.
- Secure the power module with the four #8 self-drilling screws supplied.
NOTE : Always install the power module away from a heat source
Placement of Decals
- The controller is shipped without any button decals installed.
- After assembling the controller and the mounting bracket, apply a desired decal above each button to facilitate subsequent programming and operation.
Wiring
Power Module
-
Blade Terminals
-
Positive Output 1 (max. 15A)
-
Positive Output 2 (max. 10A)
-
Positive Output 3 (max. 10A)
-
Positive Output 4
-
Positive Output 5
-
Positive Output 6
-
Positive Output 7
-
Positvie Output 8
Total current of Output 4~8 is 10A max. -
Power Indicator
-
RJ45 Cable
-
Terminal Block
-
6-Pin Wire Harness
Programming & Operation
General Operation for Programming Mode
- Programming Mode 1 and Programming Mode 2
- SW833 Controller has two programming modes.
- Programming Mode 1 allows you to configure B1~B8 and the settings of each input.
- Programming Mode 2 allows you to configure the Traffic Arrow function, input configuration of Traffic Arrow, Standby Mode, B4 flashing mode under Standby Mode and
- Buzzer ON/OFF configuration.
- You can also reset to factory default configuration in Programming Mode 2
Enter a Programming Mode
- Press B1 and B3 for more than 1 second to enter Programming Mode 1.
- Press B2 and B4 for more than 1 second to enter Programming Mode 2.
NOTE : The indicator light in the upper right corner will flash in single flash for Mode 1, or double flash for Mode 2
Change Setting Value
- Press B1 and B3 for more than 1 second to enter Programming Mode 1.
- Press the button you would like to configure. The indicator light at the upper left corner will be lit up to indicate the current setting (1 light = Setting #1, 2 lights = Setting #2… and so on).
- Press the button again to go to the next setting. The indicator light will show the current setting according the rule mentioned above.
- Press B1 and B3 for more than 1 second to exit and save your configuration
Error Signal
Under Programming Mode 1 or Mode 2, when you program a button with the function cannot be activated (e.g. B1 has been set as a permanent switch. Configure B3 to activate B1 automatically), an error occurs and the green backlight will flash three times on those buttons with three “beep” sounds.
Reset to Factory Default Configuration
- Press B2 and B4 for more than 1 second to enter Programming Mode 2.
- Press and hold B3 and B4 for more than 5 seconds.
- If SW833 Controller has been restored to factory default configuration successfully, the controller will return to operation mode (after “beep” for three times and green backlight is ON).
Automatic Standby Mode (default configuration)
Automatically enter Standby Mode after 15 minutes if no buttons are activated
and Input 1 is not activated either. (Refer to 3-6 Programming Mode 2, p.19,
for detailed information of Standby Mode Configuration)
NOTE : After entering Standby Mode, Programming Mode CANNOT be accessed
by default. If you want to enter Programming Mode, disconnect all power and
reboot your SW833 Controller.
Testing Mode (for factory users only)
- Enter Programming Mode 2.
- Press and hold B7 and B8 for more than 3 seconds.
- Under Testing Mode, you can test the connection of Input 1 / Input 2 / Input 3 respectively.
- After finishing testing, disconnect all power to exit Testing Mode.
NOTE : Testing Mode is accessible ONLY under Factory Default Configuration
Standby Mode
Enter Standby Mode Automatically (default configuration)
Automatically enter Standby Mode after 15 minutes if no buttons are activated
and Input 1 is not activated either.
Enter Standby Mode Manually (default configuration)
Manually enter Standby Mode by pressing B4 for more than 1 second. It will
turn off all button functions. (Refer to 3-6 Programming Mode 2, p.19, for
detailed information of Standby Mode Configuration)
NOTE : After entering Standby Mode, Programming Mode CANNOT be accessed
by default.
If you want to enter Programming Mode, disconnect all power and reboot your
SW833 Controller.
Default Configuration of Buttons
B1 = POSITIVE OUTPUT 1 ON/OFF switch
- Activate B1 will activate the main warning light.
- When B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
- Also Input 3 can be connected to an external switch to activate B1 (main warning light) and B2 (siren).
B2 = POSITIVE OUTPUT 2 & NEGATIVE OUTPUT 1
- Siren Interlock w/ Siren Kill
- Connect Input 2 to handbrake.
- Activate B2 will activate the siren.
- Activate B2 (siren) will also activate B1 (main warning light) simultaneously.
- When B2 (siren) is activated, turn on Input 2 (handbrake) will deactivated B2 (siren) immediately.
B3 = POSITIVE OUTPUT 3
-
Grill warning light kill w/o reverting
-
Connect Input 2 to handbrake.
-
Activate B1 (main warning light) will activate B3 (grill warning light) simultaneously.
NOTE : B3 can be activated only when B1 is activated. -
When B3 is activated, turn on Input 2 (handbrake) will deactivated B3 immediately.
NOTE : B3 will not revert when input 2 (handbrake) is off
B4 = POSITIVE OUTPUT 4 & NEGATIVE OUTPUT 2
ON/OFF switch
Activate Positive Output 4 and Negative Output 2.
B5 = POSITIVE OUTPUT 5
ON/OFF switch
Activate Positive Output 5.
B6 = POSITIVE OUTPUT 6
ON/OFF switch
Activate Positive Output 6.
B7 = POSITIVE OUTPUT 7
ON/OFF switch
Activate Positive Output 7.
B8 = POSITIVE OUTPUT 8
ON/OFF switch
Activate Positive Output 8.
Traffic Arrow Indicator Light No function
NOTE: If you want to configure Traffic Arrow Indicator Light, refer to
3-6 Programming Mode 2 (p.19) to conduct the setting operation.
Scene 1 and Scene 2 Controlled by B5 and B6
Scene Button Combo: Scene 1
Under Programming Mode 1, you can set B5 as the start button of Scene 1. While
B5 is activated, B1, B2, B3, B4 will be activated simultaneously
Scene Button Combo: Scene 2
Under Programming Mode 1, you can set B6 as the start button of Scene 2.
While B6 is activated, B1, B3, B4 will be activated simultaneously (B4 can be
added or removed in Scene 2 by B4 Setting under Programming Mode 1).
Programming Mode 1 (for setting B1~B8 button function)
Setting Example: Programming Mode 1
Press B1 and B3 for more than 1 second to enter Programming Mode 1.
Press B1 once, Setting #2 is currently selected.
Press B1 again to go to Setting #3.
After finishing setting, press B1 and B3 for more than 1 second to exit and
save your configuration.
B1 Setting (B1 controls Positive Output 1)
- You can use B1 button as an ON/OFF switch that activates the main warning light. B1 may be interlocked by B2 (refer to B2 Setting, p.14).
- When B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
- Also Input 3 can be connected to an external switch to activate B1 (main warning light) and B2 (siren).
Enter Programming Mode 1 and configure B1 Setting as the following table:
B2 Setting (B2 controls Positive Output 2 and Negative Output 1)
- You can use B2 button as an ON/OFF switch that activates the siren. And B2 may interlock
- B1, when B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
- Also input 2 can be connected to handbrake or siren status signal to deactivate B2 (siren) for siren kill.
Enter Programming Mode 1 and configure B2 Setting as the following table:
B3 Setting (B3 controls Positive Output 3)
You can use B3 button as an ON/OFF switch that activates grill warning light
and it can be activated simultaneously when B1 (main warning light) is
activated.
Enter Programming Mode 1 and configure B3 Setting as the following table:
B4 Setting (B4 controls Positive Output 4 and Negative Output 2)
You can use B4 button as a switch that activates auxiliary devices or rear
warning lights.
Enter Programming Mode 1 and configure B4 Setting as the following table:
B5 Setting (B5 controls Positive Output 5)
You can use B5 button as an ON/OFF switch that activates the traffic arrow
function (warning/ in-out mode). B5 may be set as the start button of Scene 1
to activate siren and all connected warning lights simultaneously. You can
also include B5 into Group 1 or Group 2 to activate traffic arrow function
mutually exclusive.
Enter Programming Mode 1 and configure B5 Setting as the following table:
B6 Setting (B6 controls Positive Output 6)
You can use B6 button as an ON/OFF switch that activates the traffic arrow
function (left-arrow mode). B6 may be set as the start button of Scene 2 to
activate all connected warning lights simultaneously. You can also include B6
into Group 1 / Group 2 / Group 3 to activate traffic arrow function mutually
exclusive
Enter Programming Mode 1 and configure B6 Setting as the following table:
B7 Setting (B7 controls Positive Output 7)
You can use B7 button as an ON/OFF switch that activates the traffic arrow
function (center-out mode). You can also include B7 into Group 1 / Group 2 /
Group 3 to activate traffic arrow function mutually exclusive
Enter Programming Mode 1 and configure B7 Setting as the following table:
B8 Setting (B8 controls Positive Output 8)
You can use B8 button as an ON/OFF switch that activates the traffic arrow
function (right-arrow mode). You can also include B8 into Group 1 / Group 2 /
Group 3 to activate traffic arrow function mutually exclusive
Enter Programming Mode 1 and configure B8 Setting as the following table:
Programming Mode 2
Setting Example: Programming Mode 2
Press B2 and B4 for more than 1 second to enter Programming Mode 2.
Press B1 once, Setting #2 is currently selected.
Press B1 again to go to Setting #3.
After finishing setting, press B2 and B4 for more than 1 second to exit and save your configuration.
Standby Mode Setting
Under Programming Mode 2, you can change the entry conditions of Standby Mode by B1 Setting.
Enter Programming Mode 2 and configure Standby Mode Setting as the following table:
B4 Flash Setting
Under Programming Mode 2, you can change the flash mode of B4 under Standby
Mode by B2 Setting.
Enter Programming Mode 2 and configure B4 Flash Setting as the following table:
Buzzer Setting
Under Programming Mode 2, you can change the buzzer configuration by B3
Setting.
Enter Programming Mode 2 and configure Buzzer Setting as the following
table
Traffic Arrow Function & Input 2 Setting
Under Programming Mode 2, you can change the configuration of Traffic Arrow
function and Input 2 (handbrake) by B5 Setting
NOTE : Setting #2~#4 are available only when B5, B6, B7, B8 are set as
Group1 or Group2.
Enter Programming Mode 2 and configure Traffic Arrow Function & Input 2
Setting as the following table:
Traffic Arrow Indicator Setting
Under Programming Mode 2, you can change the configuration of Traffic Arrow
Indicator by B6 Setting.
NOTE : Setting #2~#4 are available only when B5, B6, B7, B8 are set as
Group1 or Group2.
Reset to Factory Default Configuration
Under Programming Mode 2, you can use B3 and B4 to reset to factory default
configuration. Press B2 and B4 for more than 1 second to enter Programming
Mode 2
Press and hold B3 and B4 for more than 5 seconds.
If SW833 Controller has been restored to factory default configuration successfully, the controller will return to operation mode (after “beep” for three times and green backlight is ON).
Button Combo: Group 1
If the B5, B6, B7, B8 are configured in the Group 1, they are mutually
exclusive and only one button can be activated at the same time.
- B5 controls Positive Output 5.
- B6 controls Positive Output 6.
- B7 controls Positive Output 6 and 8.
- B8 controls Positive Output 8.
NOTE : Positive Output 7 is permanent positive output.
Button Combo: Group 2
If the B5, B6, B7, B8 are configured in the Group 2, they are mutually
exclusive and only one button can be activated at the same time.
- B5 controls Positive Output 5.
- B6 controls Positive Output 6.
- B7 controls Positive Output 7.
- B8 controls Positive Output 8.
Button Combo: Group 3
If the B6, B7, B8 are configured in the Group 3, they are mutually exclusive
and only one button can be activated at the same time.
- B6 controls Positive Output 6.
- B7 controls Positive Output 6, 7 and 8.
- B8 controls Positive Output 8.
Read User Manual Online (PDF format)