cell2 B18-DC Dual Colour LED Beacon User Manual

June 9, 2024
Cell2

B18-DC Dual Colour LED Beacon User Manual

WIRING / OPERATION

Permanent Mount:

BLACK: To -Chassis Ground
RED: To +VDC (fuse@5A) for Warning Mode in COLOUR1
YELLOW: To +VDC (fuse@5A) for Warning Mode in COLOUR2
 (RED + YELLOW):  To +VDC (fuse@5A) for Warning Mode in COLOUR1 alt. 2
 WHITE: [+] for Low Power Operation Activate dimming function by continuously

applying +VDC to WHITE wire.

Magnetic Mount:
NOTE: Magnetic Mount model does not feature Low Power dimming function.
BUTTON 1 – Maintained Switch:
Position 1 – ON (Warning Mode in COLOUR1)
Position 2 – OFF
BUTTON 2 – Momentary Switch:
Press 1- Warning Mode in COLOUR2.
Press 1 again – Warning Mode in COLOUR1 alt. 2
Press quick 3 times – Warning Mode in COLOUR1

FLASH PATTERNS

1| Double| [R65]
2| Single| [2HZ]
3| Triple| [2HZ]
4| Quad| [2HZ]
5| Random|
6| Steady|
7| Single| [SAE, CA13]
8| Double| [SAE]
9| Triple| [SAE]
10| Quad| [SAE]
11| Quint| [SAE]
12| Mega|
13| Ultra| [SAE]
14| Single-Quad|
15| Single H/L|
16| Single-Triple-Quint|

Note: i. This unit may not be factory-set at FP#1
ii. Actual approval base on the model ordered.

FLASH PATTERN SELECTION

cell2 B18-DC Dual Colour LED Beacon

  1. Open
    Twist the dome lens counter clockwise A , then lift the dome lens to open.

  2. Change
    While activating Warning Mode, momentarily push the RED BUTTON B to change to the next flash pattern. (see Flash Patterns Chart)
    cell2 B18-DC Dual Colour LED Beacon - Fig 1 Note: All COLOUR1, COLOUR2 and COLOUR1 alt. 2 warning modes may select different Flash Pattern.

  3. Close
    Twist and tighten the dome lens clockwise C to close.

cell2 B18-DC Dual Colour LED Beacon - Fig 2