cell2 B18-DC Dual Colour LED Beacon User Manual
- June 9, 2024
- Cell2
Table of Contents
B18-DC Dual Colour LED Beacon User Manual
WIRING / OPERATION
Permanent Mount:
BLACK: | To -Chassis Ground |
---|---|
RED: | To +VDC (fuse@5A) for Warning Mode in COLOUR1 |
YELLOW: | To +VDC (fuse@5A) for Warning Mode in COLOUR2 |
(RED + YELLOW): | To +VDC (fuse@5A) for Warning Mode in COLOUR1 alt. 2 |
WHITE: | [+] for Low Power Operation Activate dimming function by continuously |
applying +VDC to WHITE wire.
Magnetic Mount:
NOTE: Magnetic Mount model does not feature Low Power dimming function.
BUTTON 1 – Maintained Switch:
Position 1 – ON (Warning Mode in COLOUR1)
Position 2 – OFF
BUTTON 2 – Momentary Switch:
Press 1- Warning Mode in COLOUR2.
Press 1 again – Warning Mode in COLOUR1 alt. 2
Press quick 3 times – Warning Mode in COLOUR1
FLASH PATTERNS
1| Double| [R65]
2| Single| [2HZ]
3| Triple| [2HZ]
4| Quad| [2HZ]
5| Random|
6| Steady|
7| Single| [SAE, CA13]
8| Double| [SAE]
9| Triple| [SAE]
10| Quad| [SAE]
11| Quint| [SAE]
12| Mega|
13| Ultra| [SAE]
14| Single-Quad|
15| Single H/L|
16| Single-Triple-Quint|
Note: i. This unit may not be factory-set at FP#1
ii. Actual approval base on the model ordered.
FLASH PATTERN SELECTION
-
Open
Twist the dome lens counter clockwise A , then lift the dome lens to open. -
Change
While activating Warning Mode, momentarily push the RED BUTTON B to change to the next flash pattern. (see Flash Patterns Chart)
Note: All COLOUR1, COLOUR2 and COLOUR1 alt. 2 warning modes may select different Flash Pattern. -
Close
Twist and tighten the dome lens clockwise C to close.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>