Cell2 4 LED R65 Lighthead Recovery Emergency Flashing
4-LED R65 LIGHTHEAD
12-24 VDc
WIRING
-
RED: To+VDC (fuse@ 1A)
-
BLACK: To Chassis Ground
-
WIHITE: To +VDC for steady-burn
-
YELLOW: For Synchronization:
Connect YELLOW wires of all heads together for synchronization (All heads should be set at the same Flash Pattern)
For Simultaneous or Alternating Flash:- Apply +VDC to RED and YELLOW wires simultaneously to enter Grouping mode;lighthead will display short (single or double) flashes:
- Double flash = Group2
- Remove YELLOW wire from +VDC then momentarily apply it to +VDC to change Groups:
- Heads in the same Group flash together.
- Group1 Heads alternate with Group2 heads.
- Power-off to save and exit setting.
For Flash Pattern:
momentarily apply +VDC to YELLOW wire:
- once for next pattern
- quick three times to reset to FP#1
FLASH PATTERN
- Single (2Hz)
- Double (R65)
- Triple (2Hz)
- Quad (2Hz)
- All Steady
NOTE: This unit may not be factory-set at Flash Pattern #1