ThermoWorks TX-1004X-SP Pro Series High Temp Straight Penetration Probe Instructions

June 9, 2024
ThermoWorks

ThermoWorks TX-1004X-SP Pro Series High Temp Straight Penetration Probe

ThermoWorks-TX-1004X-SP-Pro-Series-High-Temp-Straight-Penetration-Probe-
product

INSTALLATION INSTRUCTION

Pro-Series High Temp Straight Penetration Probe, 4.5″ Designed for use in commercial kitchens and professional settings, the Pro-Series Probes deliver better accuracy, faster readings, unique designs, wider temperature ranges and better moisture-resistance than probes sold with low-cost houseware-grade temperature alarms.
Instructions, Tips and Cautions

  • The cable may be closed in an oven door or under a BBQ hood using the precautions below.
  • Do not pull on the cable. Use the molded mini-handle.
  • The cable will withstand 700°F (370°C) for short periods.
  • Probe tip itself is rated to 572°F (300°C). Do NOT expose probe tip to flames or coals.
  • Construction is moisture-resistant but do not immerse.
  • Keep the probe cable away from oven elements, flames, coals, grill or oven racks—all of which can reach temperatures far higher than 700°F (even if an oven is set lower).
  • The probe cable can be damaged at higher temperatures. The inner insulation will melt and the probe will short (displaying “NO PROBE” on the alarm display).
  • Avoid repeated kinking or twisting of the probe cable which can break wires.
  • With care, the probe should last a long time. Eventually, you may need to replace it. If the probe becomes damaged, the base unit will flash “NO PROBE” above the temperature display. Affordable replacements are available. Use only ThermoWorks Pro-Series Probes.ThermoWorks-TX-1004X-SP-Pro-Series-High-Temp-Straight-Penetration-Probe-fig-1

Specifications

  • Cable Max Temp: 700ºF (370ºC)
  • Transition Max Temp: 644ºF (340ºC)
  • Probe Range: -58 to 572ºF (-50 to 300ºC)
  • Cable Length: 47 inches (1.2m)
  • Probe Length: 4.5 inches (114mm)

Technical Support

  • For warranty, service, and technical assistance, please contact ThermoWorks Technical Support at 801-756-7705 or email at techsupport@thermoworks.com.

  • Use only with ThermoWorks thermometers designed for the Pro-Series. Will not work in other brands.

  • Go to www.thermoworks.com/blog for more info on chef-recommended temperatures, resting and other cooking tips.

  • ThermoWorks, Inc.

  • Utah, U.S.A.

  • Ph:801-756-7705

  • Fax:801-756-8948

  • www.thermoworks.com

  • Pro-Series®

  • High Temp Straight

  • Penetration Probe

  • TX-1004X-SP

  • P-14-001-01-a

  • Follow us on:

  • TX-1004X-SP

  • Pro-Series High Temp Straight

  • Penetration Probe

  • Designed in Utah.

  • Assembled in China.

Documents / Resources

| ThermoWorks TX-1004X-SP Pro Series High Temp Straight Penetration Probe [pdf] Instructions
TX-1004X-SP, Pro Series, High Temp Straight Penetration Probe, Pro Series High Temp Straight Penetration Probe, TX-1004X-SP High Temp Straight Penetration Probe, TX-1004X-SP Pro Series High Temp Straight Penetration Probe, Straight Penetration Probe, Penetration Probe, Probe
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ThermoWorks User Manuals

Related Manuals