1/2” THERM & PRESSURE BALANCE TRIM 23-44-45-47 TRIM SETS (STYLE VARIES BY MODEL)

HELPFUL TOOLS
For safety and ease of installation, the use of these helpful tools is recommended.

For warranty or additional information, contact:

Parts List

PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-
FIG-1

  • A. Valve Assembly (Sold Separately)
  • B. Valve Test Plug (Sold Separately)
  • C. Valve Cover and Plaster Ground (Sold Separately)
  • D. Wall Plate
  • E. Wall Plate Screws (x2)
  • F. Cartridge
  • G. Decorative Sleeve
  • H. Retaining Nut
  • I. Rosette
  • J. Handle
  • K. Handle Set Screws (x2)
  • L. Handle Set Screw Plugs (x2)

Icon Legend

  • Warning
  • Closed
  • Open

STANDARD WALL

PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-
FIG-2

ACRYLIC WALL

PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-
FIG-3PERRIN-ROWE-
UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-
FIG-4

  • If installed with a standard wall, remove Valve Cover and Plaster Ground (C).
  • If installed with an acrylic wall, remove Valve Cover (C).PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-5
  • Remove test plug (B) from Valve Assembly. Turn off stops. Remove test plug for flushing.
  • Suggested: Open stop. Flush the hot and cold supplies 20 seconds each.PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-7
  • With stops in the close or vertical position, install Cartridge (F) into the Valve Assembly. Red inlet will be on the left, blue inlet will be on the right. Ensure that the ends of the Cartridge are installed correctly. Red marking on the Cartridge to be installed on the hot water line. Blue marking on the Cartridge to be installed on the cold water line.
  • Slide Cartridge Nut onto Cartridge and hand tighten.PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-8
  • Do not overtighten the cartridge nut. Mark a line on the nut and body. With a wrench, rotate the nut closed 1/4 turn. Turn on the stops and check for leaks.
  • Install Decorative Sleeve (G) and Retaining Nut (H). Tighten nut, hand tight only.PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-9
  • Install the Wall Plate (D) and secure with Wall Plate Screws (E) (x2). Shorten the screws as needed. Apply sealant to the edges.
  • Install the Rosette (I) onto the Wall Plate assembly. Once the Rosette is installed, install the Handle (J).PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-10
  • Install the Handle Set Screws (K) (x2). Insert the Handle Set Screw Plug Buttons (L) (x2). Install the plugs with firm pressure so the handle will not slip during use.
  • Installation is complete.PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-11 PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-12 PERRIN-ROWE-UTDC23W1LSEG-1-2-Inch-Therm-and-Pressure-Balance-Trim-FIG-13