AcuityBrands DSX2 LED Area Luminaire Instructions

June 9, 2024
AcuityBrands

AcuityBrands-DSX2-LED-Area-Luminaire-LOGO

AcuityBrands DSX2 LED Area Luminaire

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered suffi ciently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

CAUTION
RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING
RISK OF BURN

  • Allow lamp/fixture to cool before handling. Do not touch  enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION
RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture speciate warnings.

Please see product speciate installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

  • Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting
  • Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT Sunoptics
  • Arancini Mark Architectural Lighting Antique Street Lamps LC&D
  • Halothane Peerless Hydrail ROAM
  • RELOC Renaissance Lighting Terse Sensor Switch
  • Light Concepts Winona Lighting Synergy

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

Installation Instructions

D-series G1nLight Air Retrofit Door
DELIVERY: Upon receipt of package, thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Tools Required: 1/4″ socket wrench. 3/16″ Allen wrench.

Link to installation video

AcuityBrands-DSX2-LED-Area-Luminaire-01

  1. Open doorframe by loosening the (2) captive screws using 3/16″ Allen wrench (Figure 1).

  2. Compare the description on the label of the original door to the description on the label of the new replacement door.

  3. The new door description will match the text of the original door description plus “NLTAIR2 PIRHNRD”.

  4. Next, compare the Watts, Volts, and Pri Amps between the 2 labels. These numbers should match.AcuityBrands-DSX2-LED-Area-Luminaire-03

  5. Using ¼” hex socket loosen (2) screws to remove hinge bracket. (Figure 2) Then lift door until it releases from the hinge-pin.AcuityBrands-DSX2-LED-Area-Luminaire-04

  6. Replace original door with new replacement door and retighten (2) screws to 30-35 in lbs.

  7. Fixture wiring:
    The photocell receptacle (Figure 3), with the shorting cap, stays installed in the fixture head. Two of the wires (brown, orange) are already capped. Leave them capped.
    Remove one of the five individual wires (black, white, red, grey and purple) exiting the photocell receptacle from the wire connector and cap it off with the provided 2-slot wire connectors (Figure 4). Use one slot only, the second slot remains empty. Proceed to step 6, one wire at a time, for each of the fi ve individual wires.

  8. Replace each individual wire unattached from the wire connector in step 5 with the corresponding color wire from the new replacement door (black for black; white for white; red for red; grey for grey; purple for purple). See Figure 5.AcuityBrands-DSX2-LED-Area-Luminaire-07Repeat steps 5 and 6, one wire at a time, until all 5 wires are connected from the fixture to the new replacement door.

  9. Close doorframe by tightening the (2) captive screws using 3/16″ Allen wrench (Figure 1) to 30-35 in lbs.

Recycle original door as required by local code.

©2010 Acuity Brands Lighting, Inc.
All Rights Reserved. 7/14

Lithonia Lighting Outdoor •
One Lithonia Way •
Conyers, Georgia 30012
Phone: 800-279-8041
Fax: 770.918.1209 •
www.lithonia.com
© 2014 Acuity Brands Lighting, Inc.
All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals