OVERVIEW
Pathway DIN PWREP DIN P4 NONRDM 4-way DMX Repeaters are essential components
of DMX512 distribution systems, permitting star-wiring while protecting
connected equipment from electrical faults.
The DIN rail-mountable form factor makes installation fast and easy.
CONNECTIONS
The PWREP DIN P4 NONRDM features terminal strips that can be removed from the card to facilitate easy wiring installation or replacement. Make the following connections, WITH THE POWER TURNED OFF.
POWER
The module will run on a range from 9 to 30 VDC at 500mA per card connection.
Observe the correct polarity when connecting the V+ and V-. A second set of
terminals are provided on the connector to daisy-chain power to other DIN
modules. The EARTH GROUND terminal must be connected to the enclosure’s
chassis or electrical ground terminal to improve EMC compliance.
DMX512
DMX connections consist of a shield and data pair. Connect the DATA+ and DATA–
wires to D1+ and D1-respectively for each of DMX IN, DMX THRU and DMX OUT.
Observe the same polarity convention throughout the system. Connect the cable
shield to the SHLD COM terminal.
DMX THRU may be daisy-chained to the DMX IN of other DIN modules. DMX OUT sends the merged signal to the DMX inputs of downstream devices.
DMX REFERENCE
DMX | XLR5 pin | DIN Terminal |
---|---|---|
Common | 1 | SHLD/COM |
Data – | 2 | D1- |
Data + | 3 | D1+ |
Unused | 4 | N/A |
Unused | 5 | N/A |
STATUS INDICATORS
POWER
Blue. Glowing steadily indicates power supply OK; off indicates no power.
DMX IN
Amber. Steady glow indicates port latched to active DMX source. Input and
Output off on all ports indicates no DMX source.
DMX OUT
Green. Steady glow indicates port is transmitting DMX. Input and Output off on
all ports indicates no DMX source.
ISO 5V
Red. Glowing steadily indicates the isolated power supply for the outputs is
OK.
DMX TERMINATE
DMX rules require the last device on a DMX line to be terminated with a 120Ω
resistor between pins 2 and 3 to prevent signal reflection. If there is no
connection to the DMX THRU terminals, the DMX Terminate switch should be ON.
If there are other devices connected to the DMX THRU terminal, the DMX
Terminate switch should be OFF and termination be applied to the final device
in the daisy-chain.
ELECTRICAL INFORMATION
- 1500V isolation from DMX input to DMX outputs
- 250V fault protection on DMX ports
- Input operating voltage: 9-30 VDC
- 6W power consumption
PHYISCAL
- 0.5 lbs (0.26 kg)
- 4.5”W x 4”H x 1.85”D (113mm x 103mm x 47mm)
- Operating conditions: 14°F-113°F (-10°C-45°C), 5-95% relative humidity, non-condensing
COMPLIANCE
- ANSI E1.11 DMX512-A R2013
- RoHS 2011/65/EU + A1 2015/863
- CE
- Class 2 Low Voltage
© 2021 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012 Pathway Connectivity | #103 – 1439 17th Ave SE Calgary, AB Canada T2G 1J9 Phone: + 1 866 617 3074 www.pathwayconnect.com