levenhuk LV40 PRO Laser Level User Manual

June 9, 2024
levenhuk

levenhuk LV40 PRO Laser Level

OVERVIEW

levenhuk-LV40-PRO-Laser-Level-FIG-1

  • 360° horizontal laser beam
  • 360° vertical laser beam
  • Lock/unlock switch
  • Vertical laser beam control button
  • Type-C USB slot
  • Tripod adapter
  • ON/OFF button
  • Horizontal laser beam control button
  • Low battery indication
  • Power indication
  • Brightness adjustment button

Ermenrich LV40 PRO Laser Level

Caution! Please remember that mains voltage in most European countries is 220–240V. If you want to use your device in a country with a different mains voltage standard, remember that use of a converter is absolutely necessary.

Charging the device
Connect the UBS Type-C cable to the device and DC adapter (not included) via a USB plug and connect it to the AC power supply. Attention! The
device operates from the AC power supply, as the voltage of the computer’s USB port is insufficient for the proper operation of the device.

WARNING: When moving the laser level or storing it, keep the switch (3) locked.

Laser beams control buttons

On the laser level Description
Blue button Controls the vertical laser beam at the front of the device
Green button Controls the horizontal laser beam

Auto-leveling mode
Slide the (3) switch to the unlock position. All the laser beams will light up. The power indicator light (10) is green. If the power indication is red
and laser beams flash frequently, place the device on a flatter surface. Two beams can be controlled by the (4)/(8) buttons. Lock the device and
turn it off.

Locked mode
Slide the (3) switch to the locked position. Press (7) and hold it for 3 seconds. All the laser beams will be flashing. The power indicator light
(10) is red. In the locked mode the device can be angled as needed. In this way, it is possible to project inclined lines and the autocalibration
will be switched off.

Brightness adjustment
When the device is in auto-leveling or locked mode, press (7). There are four brightness levels. Press (11) to change the brightness level in order to save energy.

Pulse mode
Unlock the device. Press (7) and hold it for 3 seconds to enter the pulse mode. The power indicator light (10) will be flashing. Note! Brightness
adjustment is not possible in the pulse mode.

Specifications

Laser level

  • Laser color green
  • Laser wavelength 505–550nm
  • Working distance 30m
  • Laser class class II
  • Expanded angle 2D, 8 cross lines, 360° horizontal, vertical
  • Brightness levels and working time 4 levels of brightness:
    • 1 = 11h
    • 2 = 14h
    • 3 = 23h
    • 4 = 42h
  • Compensation range 4°±1°
  • Level accuracy ±1.5mm/5m
  • Tripod adapter 1/4″
  • Protection level IP54
  • Power supply 4000mA·h built-in lithium battery, USB Type-C
  • Operating temperature range –10… +50°C (14…122°F)
  • Dimensions 98.5x53x96mm (3.8x2x3.7in)

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

Please carefully read the safety instructions and user manual before using this product. Otherwise, it may result in hazardous laser radiation and electric shock. Keep away from children. This is a class II laser product. Please DO NOT look directly into the beam with unprotected eyes or through an optical device at any time and never direct it toward other people. Do not remove any safety labels. Do not aim the device directly at the sun. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect
the device from sudden impact and excessive mechanical force. Do not use the product in explosive environment or close to flammable materials. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met. For further details, please visit: www.levenhuk.com/warranty If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals