Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fi re and/or serious injury. Save the safety warnings and the instructions for future reference.
The following symbols are used in the user manual or on the product:
Read the user manual.
Denotes risk of personal injury, loss of life or damage to the tool in case of nonobservance of the instructions in this manual
Risk of electric shock.
Not suitable for applications with external dimmers.
Minimal distance between the light source and illuminated objects.
Protection class IP65.
Replace damaged glass covers.
Do not dispose of the product in unsuitable containers.
The product is in accordance with the applicable safety standards in the European directives
SAFETY WARNINGS FOR WORK LIGHT
- a) Please read and observe all safety warnings and instructions enclosed with the fl ood light.
- b) Do not use the fl ood light in hazardous areas.
- c) Do not direct the light beam at persons or animals and do not stare into the light beam yourself (not even from a distance).
- d) Do not cover off the lens while operating the fl ood light. The fl ood light heats up during operation and can cause burns when the heat is allowed to accumulate.
- e) Do not allow children to use the fl ood light. It is intended for professional use. Children can unintentionally blind themselves or other persons.
ASSEMBLY
Place the tripod stand (Fig. B)
- Place the tripod stand (Fig. B)
- Loosen the locking screw (6).
- Fully extend the tripod legs (7).
- Re-tighten the locking screw (6).
- Place the tripod stand on a stable, level surface.
The tripod legs (7) must always be fully extended to ensure the stability of the tripod and prevent the fl ood light from tipping over / falling.
Install the support bar (Fig. C)
- Position the support bar (4) on top of the tripod stand. Align the center hole of the support bar with the tripod stand.
- Fix the support bar (4) in place by installing a locking screw (3) through the center hole.
Install the lights (Fig. D-1, D-2)
- Position a light (1) on both ends of the support bar (4). Align the hole in the light brackets with the hole on each end of the support bar.
- Fix the lights (1) in place by installing a locking screw (3) through the hole in the light brackets.
- Attach the cable splitter (8) to the support bar (4) using the screw (9).
MACHINE INFORMATION
Intended use
The twin fl ood light is intended as mobile illumination for temporary use and
is not suitable for permanent room lighting.
TECHNICAL SPECIFICATIONS
Input | 220-240V~ 50Hz |
---|---|
Power | 2x 50W (100W total) |
Luminous flux | 2x 4250lm (8500lm total) |
Beam angle | 100o |
Weight | 3.6kg |
Height | 84-176cm |
DESCRIPTION
The numbers in the text refer to the diagrams on page 2-3.
- LED light
- Locking screw
- 3. Locking screw
- Support bar
- Tube clamp
- Locking screw
- Tripod stand
- Cable splitter
- Screw
OPERATION
Be sure to keep a minimal distance of 0.5m between the lights (1) and any illuminated objects. Objects that are placed too closely may overheat.
Do not connect the fl ood light to external dimmers of any kind. The fl ood light is not suitable for use in combination with external dimmers. Using an external dimmer can cause irreparable damage to the fl ood light and/or the dimmer circuit. Only connect the fl ood light to a regular 220-240V~ 50Hz outlet.
Adjustment (Fig F-1, F-2)
The lights can be directed in any orientation. To adjust the orientation of
the lights, take the following steps:
- Slightly loosen the applicable locking screw(s) (2)/(3).
- Adjust the light(s) (1) to the desired orientation.
- Re-tighten the locking screw(s) (2)/(3).
Be careful when touching the lights. The metal housing of the lights may become hot during operation. Disconnect the fl ood light from mains power and allow it to cool down suffi ciently before making any adjustments.
The height of the tripod stand can be adjusted. To adjust the height, take the following steps:
- Slightly loosen the tube clamp(s) (5).
- Adjust the tripod stand to the desired height by extending or retracting the tube.
- Re-tighten the tube clamp(s) (5)
MAINTENANCE
The fl ood light is maintenance-free and only requires occasional exterior cleaning.
Do not open the housing of the lights, there is a risk of electric shock. The fl ood light does not contain any serviceable parts. Malfunctioning lights must be disposed of
Replace the lights in case the glass covers become damaged. Damaged lights can not be repaired and must be disposed of
The LED light source is not replaceable. When the LED light source has reached the end of its life the light must be disposed of
Cleaning
Disconnect the fl ood light from mains power and allow it to cool down suffi
ciently before cleaning. Do not use any solvents, caustic cleaning products or
similar chemicals. Use a dry or damp cloth for cleaning.
ENVIRONMENT
Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.
Only for EC countries
Do not dispose of power tools into domestic waste. According to the European
Guideline 2012/19/EC for Waste Electrical and Electronic Equipment and its
implementation into national right, power tools that are no longer usable must
be collected separately and disposed of in an environmentally friendly way
WARRANTY
VONROC products are developed to the highest quality standards and are guaranteed free of defects in both materials and workmanship for the period lawfully stipulated starting from the date of original purchase. Should the product develop any failure during this period due to defective material and/or workmanship then contact VONROC directly.
DECLARATION OF CONFORMITY WL508AC – TWIN FLOOD LIGHT 2X 50W
We declare under our sole responsibility that this product is in conformity with directive 2011/65/EU of the European parliament and of the council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulatios
EN 60598-1:2015+A1:2018, EN 60598-2-4:2018, EN 60598-2-5:2015, EN 62493:2015, EN IEC 55015:2019+A11:2020, EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, EN 61547:2009, 2006/42/EC, 2014/30/EU, 2011/65/EU, 2012/19/EU
Zwolle, 01-01-2022
H.G.F Rosberg CEO
- VONROC
- Lingenstraat 6
- 8028 PM Zwolle
- The Netherlands
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>