1. SAFETY INSTRUCTIONS
Read the enclosed safety warnings, the additional safety warnings and the
instructions. Failure to follow the safety warnings and the instructions may
result in electric shock, fire and/or serious injury. Save the safety warnings
and the instructions for future reference.
The following symbols are used in the user manual or on the product:
SAFETY NOTES
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE
AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING
USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAIN- TENANCE
SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. IF THE SUPPLY CORD IS
DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR
SIMILARLY QUALIFIED PERSON
IN ORDER TO AVOID A HAZARD. THE PLUG MUST BE REMOVED FROM THE SOCKETOUTLET
BEFORE CLEANING OR MAINTAINING THE APPLIANCE.
Please read these instructions carefully and thoroughly before using this
appliance and keep them for future reference. It is very important that you
understand how to use this appliance safely so please take the time to
familiarise yourself with the requirements as outlined in these instructions.
- If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
- Electrical connection must be protected by a residual current device (RCD) at the power socket with a nominal trip current of 30mA (max).
- Keep children and pets well away from the work area and never allow children to use this appliance or touch the extension cord at any time. When not in use, keep this appliance stored in a safe place out of reach of children.
- Never leave the appliance unattended when in use.
- Never pull the appliance by its power cord. Carry it using the carry handle.
- Do not allow the power cord to lay on or across sharp objects that might pierce the outer insulation. Carry out a visual inspection of the power cord before use and if it is damaged, have it replaced by a specialist service centre. Do not use the appliance if the cord is damaged.
- Keep the power cord away from heat, frost, oil, solvents or any sharp objects or edges.
- Electrical connections e.g. extension cable, must be protected from moisture at all times.
- Check that the power rating on your appliance corresponds with the power rating at you mains supply. The supply voltage must be 230VAC.
- Never run this appliance dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the appliance again.
- Only switch the power back on with dry hands.
- Never use this appliance in a pond or swimming pool while people are present in the water!
- Do not use the pump for drinking water.
- Corrosive, flammable or explosive substances, grease, oil, salt water and sewage must not be conveyed by the pump.
- The pH of water must between 6.5 and 8.5.
- The temperature of the liquid conveyed may not exceed 35 °C.
Electrical safety
When using electric machines always observe the safety regulations applicable
in your country to reduce the risk of fire, electric shock and personal
injury. Read the following safety instructions and also the enclosed safety
instructions.
Always check that the power supply corresponds to the voltage on the rating plate.
Connecting to the power supply Check that the power supply and plug used in accordance with your machine. Have a look at the rating plate on the machine. Any changes should always be carried out by a qualified electrician.
Warning! This machine must be earthed. If not properly earthed this machine
can cause an electrical shock. Be sure that the power supply outlet is
earthed. If there is any doubt, have it checked by a qualified electrician.
Warning! Avoid contact with the terminals on the plug when installing
(removing) the plug to (from) the power supply outlet. Contact will cause a
severe electrical shock.
Replacing cables or plugs
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Immediately throw away old cables or plugs when they have been replaced by new
ones. It is dangerous to insert the plug of a loose cable in the wall outlet.
Using extension cables
Only use an approved extension cable suitable for the power input of the
machine. The minimum conductor size is 1.5 mm². When using a cable reel always
unwind the reel completely.
2. MACHINE INFORMATION
The pressure tank unit is intended for private use for household water supply and irrigation of gardens, it is not intended for commercial use. Explosive, corrosive, flammable substances, sewage, salt water, grease and oil must not be conveyed by the pump. It is solely intended for pumping clear and rain water. The particle sizes of the solids in the water must not exceed the maximum particle size specified in the technical data.
This pump is not designed for continuous operation (e.g. as a swimming pool or pond circulation pump).
TECHNICAL SPECIFICATIONS
DESCRIPTION
The numbers in the text refer to the diagrams on page 2-5.
- ON/OFF switch
- Drain plug
- Water inlet
- Foot valve / backflow preventer (not included)
- Filling plug
- Water outlet
- Pressure tank
- Suction hose (not included)
- Pressure switch
- Pressure gauge
- Pressure tank valve
- Pressure tank valve cap
- Feet (with drill holes)
3. ASSEMBLY
Before carrying out any work on the pump, disconnect the mains plug from the
power supply.
Installing the pump (Fig. A,D) The pump should be installed in ventilated and
dry environment. It could be installed outside, provided having proper
covering to prevent rain and wind. Make sure the pump is placed on the
horizontal and stable ground. Always put up the pump at a point higher than
the water surface, as shown on figure D.
For a permanent installation, the feet (13) of the device can be bolted to the ground.
Attaching the suction hose (Fig. A, C, D)
⚠ Don’t use any hose connection system fittings or standard water hoses on the
suction side! A suction hose (8) set with suitable coupling (G1″ external
thread) and foot valve (4) must be used. The foot valve (4) prevents the
return flow of the water at the end of the pumping process.
⚠ 25mm, 32mm or 38mm (inner diameter) suction hose (8) must be used to achieve maximum flow rate.
⚠ The suction hose (8) should be as short as possible.
- Remove the protection cap from the water inlet connection.
- Fill suction hose (8) with clean tap water, as shown on figure C.
- Apply thread seal tape (Teflon tape) to the threaded suction hose coupling.
- Screw the suction hose coupling airtight into the water inlet (3).
- The foot valve (4) must be placed vertically and at least 30 cm from the water bottom to prevent the suction of sand and stones, as shown on figure D.
Attaching the outlet hose (Fig. A)
⚠ The larger the hose and hose connector diameter, the greater the flow.
⚠ The lower the delivery height, the greater the flow.
- Remove the protection cap from the water outlet (6) connection.
- Decide which hose diameter and hose connection system fittings you are going to use.
- Apply thread seal tape (Teflon tape) to the chosen threaded coupling.
- Screw the coupling (not included) into the water outlet (6).
- Connect the hose (not included) to the coupling. 6. Check that the hose has no kinks in it.
Filling the pump with water (Fig. A, E)
- Unscrew and remove the filling plug (5).
- Fill the pump with clean tap water, as shown on figure E. Do not overfill the pump.
- Place the filling plug (5) back, do not overtighten.
4. OPERATION
⚠ Never use this pump in a pond or swimming pool while people are present in
the water!
⚠ Only switch the power on or off with dry hands.
⚠ Never run this pump before the pump and the suction hose (8) is filled with
water.
⚠ Clean the foot valve (not included) and pre-filter (not included) at regular
intervals, and check it for damage. Otherwise, its function can be impaired.
Switching on/off (Fig. A)
- Check that the ON/OFF switch (1) of the pump is in the `O’ position before connecting the pressure switch to the power supply.
- Move the ON/OFF switch (1) of the pump into the position `I’ to switch the pump on. Open the connected tap or spray gun. When you start the pump, there will be a lot of air in the water first. This is not a defect of your pump, but serves to remove air from the pump. It may take several minutes for the air to escape when the pump is used for the first time.
- When you close the connected tap or the spray gun, the pump automatically stops pumping. Now the pump is ready for use.
- With the pressure switch (9) you can automatically control the operation of the pump. When you open the connected tap or the spray gun, the pump automatically starts pumping. The switch-on pressure is 1.4 bar.
- When you close the connected tap or the spray gun, the pump automatically stops pumping. The switch-off pressure is 2.8 bar.
Reading the pressure (Fig. A)
The pipe pressure can be read on the pressure gauge (10). The black scale
indicates the pressure in bar.
Finish operation (Fig. A, F)
⚠ Do not touch the pump unless its power has been cut off for at least 5
minutes.
⚠ When there is the risk of frost or if you do not use your pump for a long
time, please properly store your pump.
- Check that the ON/OFF switch (1) is in the `O’ position.
- Remove the mains plug from the mains.
- Unscrew and remove the drain plug (2). Let the water drain.
- Pull up the suction hose (be aware, it is full of water).
- Unscrew the suction hose (8) from the water inlet (3).
- Remove the filter and foot valve (4), then rinse with clear water. Make sure that there is no water left in the suction hose (8).
- Remove the water hose from the water outlet (6). Unscrew the coupling from the water outlet (6).
- Place the drain plug (2) back, do not overtighten.
- Clean and store the device (see ‘Maintenance’)
5. MAINTENANCE
Before cleaning and maintenance, always switch off the machine and remove the
mains plug from the mains.
Clean the machine casings regularly with a soft cloth, preferably after each
use. Remove very persistent dirt using a soft cloth moistened with soapsuds.
Do not use any solvents such as gasoline, alcohol, ammonia, etc. Chemicals
such as these will damage the synthetic components.
If the appliance appears to be blocked, switch off the power at the mains,
remove the plug from the socket and check the appliance for blockages. Clean
suction hose, foot valve, pre-filter and pump.
Air pressure tank (Fig. G)
- Check that the ON/OFF switch (1) is in the `O’ position.
- Remove the mains plug from the mains.
- Open the connected tap or spray gun to reduce the pressure.
- Unscrew the pressure tank valve cap (12) from the pressure tank valve (11).
- Use an airbag to check the air pressure, as shown on figure E. It should be 1.5 until 1.8 bar.
- If necessaire, pumping in or releasing air.
- Place the pressure tank valve cap (12) back.
STORAGE AND FROST POTECTION
The garden pump and accessories that are not completely drained can be
destroyed by frost. Completely drain the garden pump and accessories and
protect them against frost. Keep this appliance in well-ventilated dry
premises with temperature not going below +5°C.
When not in use, keep this appliance stored in a safe place out of reach of
children.
TROUBLE SHOOTING GUIDE
ENVIRONMENT
Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.
Only for EC countries Do not dispose of power tools into domestic waste. According to the European Guideline 2012/19/ EU for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way.
WARRANTY
VONROC products are developed to the highest quality standards and are
guaranteed free of defects in both materials and workmanship for the period
lawfully stipulated starting from the date of original purchase. Should the
product develop any failure during this period due to defective material
and/or workmanship then contact VONROC directly.
The following circumstances are excluded from this guarantee:
- Repairs and or alterations have been made or attempted to the machine by unauthorized service centres;
- Normal wear and tear;
- The tool has been abused, misused or improperly maintained;
- Non-original spare parts have been used.
This constitutes the sole warranty made by company either expressed or implied. There are no other warranties expressed or implied which extend beyond the face hereof, herein, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall VONROC be liable for any incidental or consequential damages.
The dealers remedies shall be limited to repair or replacement of
nonconforming units or parts.
The product and the user manual are subject to change. Specifications can be
changed without further notice.
DECLARATION OF CONFORMITY
GP529AC / GP530AC – PRESSURE TANK UNIT
We declare under our sole responsibility that this product is in conformity with directive 2011/65/EU of the European parliament and of the council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations:
GP529AC:
Measured sound power level: 74.5 dB(A)
Guaranteed sound power level: 77 dB(A)
GP530AC:
Measured sound power level: 78.1 dB(A)
Guaranteed sound power level: 81 dB(A)
Conformity assessment method to Annex V Directive 2000/14/EC amended by
2005/88/EC.
The notified body involved: TÜV SÜD Industrie Service GmbH, Certification Body
of the Notified Body 0036
EN 60335-1, EN 60335-2-41, EN 62233, EN 55014-1, EN55014-2, EN 61000-3-2,
EN61000-3-3, 2006/42/EC,
2014/30/EU, 2011/65/EU, (EU)2015/863, 2012/19/EU, 2000/14/EC, 2005/88/EC
©2021 VONROC
WWW.VONROC.COM
2112-17
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>