SKU: SP817-1
Quickstart
This is a
secure
Alarm Sensor
for
CEPT (Europe).
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
1. Put the Z-Wave Controller into inclusion mode.2. Press the tamper switch 3
times within 1.5 seconds to put the unit into inclusion mode.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This presence detector using PIR (passive infrared receiver) detects the presence of a person in a room. The units compatible with S2 security, send information to a controller or any other associated Z-Wave device. Up to 4 devices can be controlled from this device. The sensor is a battery-powered device, which is in sleeping mode unless an action is detected. After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping mode. Batteries can be changed without unscrewing the device from the door or frame. The unit will give a visual warning on the device and sends a warning to the Z-Wave controller, when batteries need to be replaced. The unit offers a tampering control and sends an alarm message when tampered.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds).3. Node ID is excluded. The device reverts to factory default state and will be in auto- inclusion mode for 4 minutes.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Put the Z-Wave Controller into inclusion mode.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode.
Exclusion
1. Put the Z-Wave Controller into exclusion mode.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The Motion detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life.The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:1) Minimum Wake Up Interval 600s (10 minutes)2) Maximum Wake Up Interval 86400s (1 day)3) Default Wake Up Interval 14400s (4 hours)4) Wake Up Interval Step Seconds 600s (10 minutes)
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline |
---|---|---|
2 | 4 | PIR Control |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Basic Set Level
When Basic Set Command is sent where contains a value, the receiver will
take it for consideration; for instance, if a lamp module is received the
Basic Set command of which value is decisive as to how bright of dim level of
lamp module shall be.
Size: 1 Byte, Default Value: 99
SettingDescription
1 – 99 | Basic Set Level |
---|
Parameter 3: Sensitivity Level
In order to provide a best efficiency of the detector, it is recommended to
test the detector with movements from a farthest end of the coverage area at
first time of use.If movements cannot be detected sensitively, simply adjust
the sensitivity level with Configuration Parameter #3. This parameter can be
configured with the value of 1 through 10, where 1 means low sensitivity and
10 means highest sensitivity.
Size: 1 Byte, Default Value: 6
SettingDescription
1 – 10 | Sensitivity Level |
---|
Parameter 4: Re-trigger Interval
_The Configuration parameter that can be used to adjust the interval of being re-triggered after the detector has been triggered as Configuration Parameter
4.No response will be made during this interval if a movement is
presented.The time interval can be set between 5 secs to 3600 secs._
Size: 2 Byte, Default Value: 180
SettingDescription
5 – 3600 | Re-trigger Interval |
---|
Parameter 5: Lux Level
The user can set a detecting percentage of lux level which determines when
the light sensor will be activated.If percentage of lux level of ambient
illumination falls below this percentage, and a person moves across or within
the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set
Command (Value = Basic Set Level)) to controller and activate connected
modules and lighting.Percentage can be set between 1% to 100%.
Size: 1 Byte, Default Value: 20
SettingDescription
1 – 100 | Lux Level |
---|
Parameter 6: On-Off Duration
The function of on-off duration setting will be useful if the detector is
connected with a module or lighting.The duration determines how long the
module/lighting should stay ON.For instance, Lamp Module turns off 100 secs
after it has been turned on.This parameter can be configured with the value of
5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of
delay.
Size: 2 Byte, Default Value: 15
SettingDescription
5 – 3600 | On-Off Duration |
---|
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00:00.05 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18066147 |
Z-Wave Product Id | 0x0060.0x0001.0x0006 |
Color | White |
Supported Notification Types | Home Security |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Notification V4
- Powerlevel
- Security
- Security 2
- Supervision
- Transport Service V2
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.