EVERSPRING SP201 PIR Motion Detector Instruction Manual
- October 27, 2023
- EVERSPRING
Table of Contents
SP201 PIR Motion Detector
Instruction Manual
General Introduction
The SP201 PIR Motion Detector is uses a Passive Infra-Red (PIR) sensor to
detect motion, along with a temperature & humidity sensor to fulfill the needs
of home security and home automation applications. Its great compatibility
with our U-Net family security products makes it suitable for smart home cloud
based platforms.
Product Overview
A. LED indicator | G. Screw mounting hole |
---|---|
B. PIR sensor | H. vent |
C. Slot | I Battery |
D. Battery mylar | J Learning button |
E. Backplate | K Tamper |
F. corner mount surface |
Accessories
Pairing to controller
-
Use a screwdriver to open the back plate and insert 4 AAA batteries as shown below.
-
Log into the VIAS account from the APP, and enter the gateway to system main control page.
-
Select Menu List>System Setup>ADD DEVICE>choose “Installation” on PIR.
-
Please follow and complete the instruction on the APP to binding with central gateway.
-
Locate the learning button “J” (see Product Overview). Do not activate pairing on the controller yet.
-
Press and hold the learning button for more than 3 seconds until the LED flashes moderately then release the button.
-
Quickly activate pairing on the controller. The LED should stop blinking indicating the pairing process is complete.
Mounting
Choosing a location
The detector is suitable for mounting indoor in dry interior locations only.
When considering a location for the detector the following points should be
considered:
- Do not locate the detector facing a window or where it is exposed to or facing direct sunlight. PIR detectors are not suitable for use in conservatories.
- Do not locate the detector where it is exposed to ventilators.
- Do not locate the detector directly above a heat source, (e.g. fire, radiator, boiler, etc).
- Do not locate the detector in a position where it is subject to excessive vibration.
Where possible, mount the detector in the corner of the room so that the logical path of an intruder would cut across the detection zone. PIR detectors respond more effectively to movement across the detection area than to movement directly towards the sensor.
Mount the PIR detector at height of 1.8m. At this height, the detector will
optimize the detection range of up to 8m with a field of view of 90°.
Mounting by tape:
1. Stick the 3M tapes on surface “F” (see Product Overview) then align
SP201 onto the wall corner.
4. Align
the top of the detector to clip it onto the top edge of the back plate. Then
push the bottom edge of the detector into place and refit the fixing screw at
the bottom secure into position
5. Use the controller’s smartphone app to test the detector to ensure it is
working properly.
Maintenance
Low Battery: When the battery becomes low, it will report to the controller
Software reporting commands
Battery condition | Auto report battery condition to controller every hour. |
---|---|
Status change | 1.PIR trigger: SP201 would report to controller. |
2.Sudden change of temperature over 2 degrees: SP201 would report to
controller.
Temperature and Humidity report| SP201 will detect every 5 minutes and report
every 30 minutes. The report period can be set from 300 sec- 3600 sec. through
the controller.
Operation mode| Warm up time is 1 minute, LED would flash 3secs/time during
the period. When it’s ready, the LED would flash for 5 secs.
PIR trigger period| 1. Can be set between 30sec to 3600 sec.
2.Default: 1st Re-Trigger time is 30 sec, 2nd Re-Trigger time is 60 sec , 3rd
and so on Re-Trigger time is 120 sec, If there’s no PIR trigger over
120sec,then the trigger time would return to 1st trigger of 30 sec.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact your original retailer or nearest service center if the below solutions cannot solve your problem.
Symptom | Possible Cause | Recommendation |
---|---|---|
LED cannot be displayed | No power. | Check if batteries are inserted correctly |
or replace with new ones.
The detector is not working| The PIR detector cannot communicate with the
controller.| Place the PIR detector closer to the controller.
LED does illuminate, appliance does not respond| Binding with controller did
not complete successfully.| Bind again using manual binding
Reset to Factory Settings
- Press and hold the learning button for 3 or more seconds, and the detector LED will start to flash.
- Press and hold the link key for 6 or more seconds within 30 seconds until the LED turns off. The device is now reset back to factory mode
Specifications
Operating temperature range | -10°C to 40°C |
---|---|
Operating humidity | 85% RH at 30°C |
PIR Detection Coverage | Up to 8m x 90° (at 1.8m mounting height & below 25°C) |
Battery type | AAA alkaline 1.5V *4 |
Warm Up Time | About 1 minute |
RF Frequency | 868 MHz Band range (EU) |
923 MHz Band range (US)
RF transmission range| Up to 800m (Open space)
FCC ID| FU5SP201-2
IC| 23210-SP2012
Specifications are subject to change without notice.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
your health and well-being. When replacing old appliances with new ones, the
retailer is legally obligated to take back your old appliance for disposal
free of charge.
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS
Federal Communication Commission Interference Statement
FCC warning:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note:** This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation
is subject to the
following two conditions:
- This device may not cause harmful interference,
- this device must accept any interference received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
Industry Canada statement:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
www.everspring.com