Everspring Industry SR202 Remote Keyfob Instruction Manual
- June 3, 2024
- Everspring Industry
Table of Contents
SR202
REMOTE KEYFOB
General Introduction
The SR202 Keyfob is a portable remote control used to set the alarm controller
into Arm, Partial Arm and Disarm modes. The Keyfob also incorporates a Panic
function that will immediately initiate an emergency panic condition at any
time.
Note: The actual operation for each buttons depends on the settings on
the controller.
Product Overview
A LED indicator | B, C, D, E Buttons | F Battery cover |
---|---|---|
C Learning button | D Panic button |
Note: The actual operation for each button depends on the settings on the controller.
Pairing to Controller
- Set the Controller into Pairing mode.
- Insert one CR2032 coin cell battery into the Keyfob.
- Log into the VIAS account from the APP, and enter the gateway to system main control page.
- Select Menu List>System Setup>ADD DEVICE>choose “Installation” on Remote.
- Please follow and complete the instruction on the APP to binding with central gateway.
- Press and hold the right button (C) for over 3 seconds until the LED blinks rapidly in green, then release.
- Within 5 secs, the LED will stop blinking, indicating the pairing procedure has completed.
Operation
Scenes button
Each button, when pressed once, will activate a scene operation defined by the
Controller.
Refer to the Controller’s user manual for assigning scenes for each button.
LED indication
Green, blink once : Command sent to Controller Green, blink once : Received
and acknowledged by Controller Red, blink once : No reply from Controller
Panic
The bottom button (D) has an additional Panic function. Long press this button
for 2 secs will send a Panic command to the controller, indicated by the
flashing green and red of the LED.
Maintenance
Low Battery: When the battery becomes low, the LED will flash red twice whenever a button is pressed. Replace the battery when possible.
Troubleshooting
The troubleshooting table lists some possible causes and solutions.
Symptom | Cause of Failure | Recommendation |
---|---|---|
LED cannot be displayed | 1.Run out of battery power. | |
2.Check if reverse battery polarity. | 1.Replace a new battery. |
2.Refit the battery with correct polarity.
LED turns red after
pressing the button| Keyfob is out of range of the Controller.| 1.Move closer
to the Controller
2.Hold the keyfob higher and press again.
LED blinks green slowly for 30secs after power on.| Keyfob has not bind with
Controller| 1. Remove the battery and perform pairing to Controller.
LED Table
The table below summarizes the LED indication of the keyfob.
Function | LED color |
---|---|
Command sent | Green, blink once |
Received by Controller | Green, blink once |
No reply from Controller | Red, blink once |
Panic | Red and green, blinking |
Low battery | Red, flash twice |
Pairing in process | Green, flashing every second for 30 secs |
Pairing successful | LED stops flashing |
Pairing Fail | Green, flash 3 times. |
Reset to Factory Settings
- Press and hold the right button (C) for over 3 seconds until the LED blinks green rapidly, then release.
- Within 30 secs, press and hold the right button again for more than 6 seconds until the LED turns off, then release. The LED will start blinking slowly once every 2 secs. This implies the device is reset back to factory mode.
Note: After power on, the Keyfob will automatically enter “Auto-pairing” mode to pair with a gateway. This process lasts for 30 seconds, indicated by the LED blinking every second.
Specifications
Operating temperature range | -20°C to 50°C |
---|---|
Operating humidity | 95% RH Max |
Battery type | CR2032 3V*1 |
RF Frequency | 868MHz Band range (EU) 923MHz Band range (US) |
RF transmission range | Outdoor >300m (Open space) |
FCC ID | FU5SR202-2 |
IC | 23210-SR2022 |
** Specifications are subject to change without notice.
WARNING: Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
your health and well-being. When replacing old appliances with new ones, the
retailer is legally obligated to take back your old appliance for disposal
free of charge.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Federal Communication
Commission Interference Statement
FCC warning: Any Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation
is subject to the
following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
Industry Canada statement: This device complies with Industry Canada
licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) This device must accept any interference,
including interference that
may cause undesired operation of the device. This equipment complies with IC
RF radiation exposure limits set forth for an uncontrolled environment.
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
50 Sect. 1 Zhonghua Rd Tucheng
NewTaipeiCity 236 Taiwan
www.everspring.com