GE In-Wall Smart 1000W Dimmer 14299/ZW3006 Manual

June 8, 2024
GE

GE

In-Wall Smart 1000W Dimmer

SKU: 14299/ZW3006

Quickstart

This is a ****

Light Dimmer
for
U.S. / Canada / Mexico
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
1. Follow the instructions for your Z-Wave certified controller toinclude a device to the Z-Wave network.2. Once the controller is ready to add your device,press and release the top or bottom of the wireless smartswitch (rocker) to add it in the network.Please reference the controllers manual for instructions.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Transform any home into a smart home with the GE Z-WaveSmart 1000W Dimmer. The In-Wall Smart 1000W Dimmer can easily replace any standard in-wall switch and remotely controls a light in your home. Your home will be equipped with ultimate flexibility with the GE Z-Wave Smart 1000W Dimmer, capable of being used by itself or with up to four add-on switches. Screw terminal installation provides improved space efficiency when replacing existing switches and the integrated LED indicator light allows you to easily locate the switch in a dark room. The GE Z-Wave In-Wall Smart 1000W Dimmer is compatible with any Z-Wave certified gateway, providing access to many popular home automation systems. Take control of your home lighting with GE Z-Wave Smart Lighting Controls! Z-Wave is the worlds largest ecosystem of inter operable smart home products. Z-Wave lighting controls provide an easy-to-install and affordable system to control lighting and small appliances in your home. Add GE Z-Wave lighting controls to a Z-Wave certified gateway to access and control your home from anywhere in the world using your smartphone, tablet or computer as a home automation command center. Never worry if you accidentally left the lights on because you can turn them off remotely or program your lights to go on/off at specific times. Create customized lighting scenes for any occasion such as a go to sleep scene or a movie night scene. Give the illusion that someone is home by programming the lights to turn on/off while you are awayperfect for deterring crime and adding additional security!”

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Quickly press ON (Top) button three (3) times then immediatelypress the OFF (Bottom) button three (3) times. The LED will flashON/OFF 5 times when completed successfully.NOTE: This should only be used in the event your networksprimary controller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

1. Follow the instructions for your Z-Wave certified controller toinclude a device to the Z-Wave network.2. Once the controller is ready to add your device,press and release the top or bottom of the wireless smartswitch (rocker) to add it in the network.Please reference the controllers manual for instructions.

Exclusion

1. Follow the instructions for your Z-Wave certified controller toremove a device from the Z-Wave network.2. Once the controller is ready to Exclude your device, pressand release the top or bottom of the wireless smart dimmer(rocker) to remove it from the network.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Z-Wave Plus Lifeline, Multilevel Switch Report
2 5 Support Basic Set and is controlled with the local load
3 5 Supports Basic Set and is controlled by double pressing the On or Off

button

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 10: Dim Rate Adjustments

Dim Rate Adjustments when manually controlling dimming
Size: 2 Byte, Default Value: 3

SettingDescription

1 – 255 timing of steps

Parameter 11: Dim Rate Adjustments

Dim Rate Adjustments when receiving an All-On or All-Off command
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 99 number of steps or levels

Parameter 12: Dim Rate Adjustments

Dime Rate Adjustments when receiving an All-On or All-Off command
Size: 2 Byte, Default Value: 3

SettingDescription

1 – 255 timing of steps

Parameter 3: LED Light

When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3s value to 1. To turn the LED OFF at all times, change parameter 3s value to 2.
Size: 1 Byte, Default Value: 0

SettingDescription

1 LED ON when load is ON
2 LED always OFF
0 Default

Parameter 4: Invert Switch

If the switch is accidentally installed upside down with On at the bottom and Off at the top, the default On/Off rocker settings can be reversed by changing parameter 4s value to 1.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Default
1 Invert Switch

Parameter 7: Dim Rate Adjustments

Dim Rate Adjustments when receiving Z-Wave dim command
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 99 number of steps or levels

Parameter 8: Dim Rate Adjustments

Dim Rate Adjustments when receiving a Z-Wave dim command
Size: 2 Byte, Default Value: 3

SettingDescription

1 – 255 timing of steps

Parameter 9: Dim Rate Adjustments

Dime Rate Adjustments when manually controlled dimming
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 99 number of steps or levels

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 5.19
Z-Wave Version 6.51.08
Certification ID ZC10-17015390
Z-Wave Product Id 0x0063.0x4944.0x3039
Color White
Neutral Wire Required ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Crc 16 Encap
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Powerlevel
  • Scene Activation
  • Scene Actuator Conf
  • Switch All
  • Switch Multilevel V2
  • Version V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE User Manuals

Related Manuals