NodOn Soft Remote CRC-3-6-0X Manual
- June 8, 2024
- NODON
Table of Contents
- NodOn
- NodOn Soft Remote
- SKU: CRC-3-6-0X
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Special Operations as Z-Wave Controller
- Configuration Parameters
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NodOn
NodOn Soft Remote
SKU: CRC-3-6-0X
Quickstart
This is a ****
Remote Control – Multi Purpose
for
U.S. / Canada / Mexico.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1- Place your home automation gateway into Inclusion Mode. To do so, please
refer to your gateways user guide.2- Simultaneously push on buttons 1 and 2,
during 1 second. The LED glows in pink to confirm the selection. 3- Push on
button 1. The LED blinks in pink to confirm your choice.4- The LED blinks in
green to confirm the procedure
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The NodOn Soft Remote controls any compatible receivers Z-Wave or Z-Wave Plus, such as the Smart Plug NodOn. It can address, directly, up to 4 groups of 8 devices and sent up to 16 different scenes to a Home Automation Gateway. This controller can operate on its own (Standalone Mode) or as gateways assistant (Gateway Mode). The product integrates a LED, which give an intuitive feedback for each operation you perform. Based on an innovative technology, the NodOn Soft Remote is only powered with a CR2032 battery, offering 2 years autonomy. The NodOn Soft Remote is based on brand new 500 series Z-Wave module from Sigma Designs, and supports all the new features of Z-Wave Plus standard: Longer range (up to 40 meters indoor), lower power consumption, higher data rate transmission, and many more new features.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Simultaneously push on buttons 3 and 4, during 1 second. The LED will blink red and green to validate the factory reset.A factory reset will completely delete the memory of the Soft Remote and restore all parameters to default value.In “Standalone” Mode, make sure to remove all the devices added or associated in the Soft Remote’s network before performing a factory reset. In “Gateway” Mode, use the factory reset procedure only when the primary controller (i.e the Gateway) is missing or defective. Reset the Soft Remote does not mean that it has been removed from the primary controller memory. Remove the Soft Remote (through the primary controller) before performing a factory reset.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1- Place your home automation gateway into Inclusion Mode. To do so, please refer to your gateways user guide.2- Simultaneously push on buttons 1 and 2, during 1 second. The LED glows in pink to confirm the selection. 3- Push on button 1. The LED blinks in pink to confirm your choice.4- The LED blinks in green to confirm the procedure
Exclusion
1- Place your home automation gateway into Inclusion Mode. To do so, please refer to your gateways user guide.2- Simultaneously push on buttons 1 and 2, during 1 second. The LED glows in pink to confirm the selection. 3- Push on button 1. The LED blinks in pink to confirm your choice.4- The LED blinks in green to confirm the procedure
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
When the product in “Gateway” mode, any action on button will send a wake up notification to the gateway.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Z-Wave Plus Lifeline. This group is used to report information of the
OCTAN Remote to the Main Controller of the network.
---|---|---
2| 8| Button 1MONOControlled nodesA short press will activate (ON) your
associated devicesA second short press will deactivate (OFF) your associated
devices. If some of the associated devices have dimming features (light
dimmer, roller shutter, etc.):A long press will dim up your associated devices
(light, roller shutter, etc.) until you release the buttonA second long press
on the same button will dim down your associated devices (light, roller
shutter, etc.) until you release the button.
3| 8| Button 2MONOControlled nodesA short press will activate (ON) your
associated devicesA second short press will deactivate (OFF) your associated
devices. If some of the associated devices have dimming features (light
dimmer, roller shutter, etc.):A long press will dim up your associated devices
(light, roller shutter, etc.) until you release the buttonA second long press
on the same button will dim down your associated devices (light, roller
shutter, etc.) until you release the button.
4| 8| Button 3MONOControlled nodesA short press will activate (ON) your
associated devicesA second short press will deactivate (OFF) your associated
devices. If some of the associated devices have dimming features (light
dimmer, roller shutter, etc.):A long press will dim up your associated devices
(light, roller shutter, etc.) until you release the buttonA second long press
on the same button will dim down your associated devices (light, roller
shutter, etc.) until you release the button.
5| 8| Button 4MONOControlled nodesA short press will activate (ON) your
associated devicesA second short press will deactivate (OFF) your associated
devices. If some of the associated devices have dimming features (light
dimmer, roller shutter, etc.):A long press will dim up your associated devices
(light, roller shutter, etc.) until you release the buttonA second long press
on the same button will dim down your associated devices (light, roller
shutter, etc.) until you release the button.
6| 8| Buttons 1&3DUOControlled nodesA short press on button 1 will activate
(ON) your associated devices.A short press on button 3 will deactivate (OFF)
your associated devices. If some of the associated devices have dimming
features (light dimmer, roller shutter, etc.):A long press on button 1 will
dim up your associated device (light, roller shutter, etc.) until you release
the button.A long press on button 3 will dim down your associated device
(light, roller shutter, etc.) until you release the button.
7| 8| Buttons 2&4DUOControlled nodesA short press on button 2 will activate
(ON) your associated devices.A short press on button 4 will deactivate (OFF)
your associated devices. If some of the associated devices have dimming
features (light dimmer, roller shutter, etc.):A long press on button 1 will
dim up your associated device (light, roller shutter, etc.) until you release
the button.A long press on button 3 will dim down your associated device
(light, roller shutter, etc.) until you release the button.
Special Operations as Z-Wave Controller
As long as this device is not included into a Z-Wave network of a different
controller
it is able to manage its own Z-Wave network as primary controller. As a
primary controller
the device can include and exclude other devices in its own network, manage
associations,
and reorganize the network in case of problems. The following controller
functions
are supported:
Inclusion of other devices
Communication between two Z-Wave devices only works if both belong to the same
wireless network. Joining a network is called inclusion and is initiated by a
controller.
The controller needs to be turned into the inclusion mode. Once in this
inclusion mode
the other device needs to confirm the inclusion – typically by pressing a
button.
If current primary controller in your network is in special SIS mode this and
any other secondary controller can also include and exclude devices.
To become
primary a contoller have to be resetted and then include a device.
1- Push 3 times (quickly) on the button 1. The LED blinks in blue.2- Place the device you want to add in “Learning” Mode, within 10 seconds. To do so, please refer to your device’s user guide.3- The LED blinks in green to confirm the inclusion.
Exclusion of other devices
The primary controller can exclude devices from the Z-Wave network. During
exclusion
the relationship between the device and the network of this controller is
terminated.
No communication between the device and other devices still in the network can
happen
after a successful exclusion. The controller needs to be turned into the
exclusion mode.
Once in this exclusion mode the other device needs to confirm the exclusion –
typically
by pressing a button.
Attention: Removing a device from the network means that it is turned
back
into factory default status. This process can also exclude devices from it’s
previous
network.
1- Push 3 times (quickly) on the button 4. The LED blinks in blue.2- Place the device you want to remove in “Learning” Mode, within 10 seconds. To do so, please refer to your device’s user guide.3- The LED blinks in green to confirm the exclusion.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Buttons 1 and 3 Profile
To set-up the profie of buttons 1 & 3
Size: 1 Byte, Default Value: 0
SettingDescription
2 | DUO. Button 1 is paired with button 3. |
---|---|
0 | SCENE. Product sends Central Scene Notification Commands or Scene |
Activation Commands.
1| MONO. Button 1 is not paired with button 3.
Parameter 2: Buttons 2 and 4 Profile
To set-up the profie of buttons 2 & 4
Size: 1 Byte, Default Value: 0
SettingDescription
1 | MONO. Button 1 is not paired with button 3. |
---|---|
0 | SCENE. Product sends Central Scene Notification Commands or Scene |
Activation Commands.
2| DUO. Button 1 is paired with button 3.
Parameter 3: Scene Type
To choose the way of sending Scene to the gateway
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Use CENTRAL SCENE Commands. |
---|---|
1 | Use SCENE ACTIVATION Commands. |
Parameter 4: Button 1 Configuration
To set-up the how button 1 behaves, when set in MONO Profie
Size: 1 Byte, Default Value: 0
SettingDescription
2 | Single Press sends broadcast Switch All Off Command. |
---|---|
0 | Single Press sends Basic Set Command to associated devices in Group 2. |
1 | Single Press sends broadcast Switch All On Command. |
Parameter 5: Button 2 Configuration
To set-up the how button 2 behaves, when set in MONO Profie
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Single Press sends broadcast Switch All On Command. |
---|---|
2 | Single Press sends broadcast Switch All Off Command. |
0 | Single Press sends Basic Set Command to associated devices in Group 3. |
Parameter 6: Button 3 Configuration
To set-up the how button 3 behaves, when set in MONO Profie
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Single Press sends broadcast Switch All On Command. |
---|---|
2 | Single Press sends broadcast Switch All Off Command. |
0 | Single Press sends Basic Set Command to associated devices in Group 4. |
Parameter 7: Button 4 Configuration
To set-up the how button 4 behaves, when set in MONO Profie
Size: 1 Byte, Default Value: 0
SettingDescription
2 | Single Press sends broadcast Switch All Off Command. |
---|---|
1 | Single Press sends broadcast Switch All On Command. |
0 | Single Press sends Basic Set Command to associated devices in Group 5. |
Parameter 8: Led Management
How to set up LED behaviour
Size: 1 Byte, Default Value: 0
SettingDescription
0| Led does not acknowledge button action and does not acknowledge result of
radio command sent.
---|---
3| Combined behaviors of 0x01 and 0x02 modes.
2| When the end-user sends a controlled command: Basic Set Command or Central
Scene Notification Command or Multilevel Switch Stop Level Change Command. Led
blinks GREEN to acknowledge transmission success or blinks RED to acknowledge
transmission failed.
1| When the end-user performs a Single press, Double press or Hold Press on a
button, led blinks blue to acknowledge the button action.
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Remote Control – Multi Purpose |
Network Operation | Portable Controller |
Firmware Version | HW: 1 FW: 3.03:01.05 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16085195 |
Z-Wave Product Id | 0x0165.0x0002.0x0002 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Application Status
- Basic
- Central Scene V2
- Scene Activation
- Switch All
- Switch Multilevel V3
- Wake Up V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>