Simon S100 Rocker iO for Dimmer 10002020-13X Manual
- June 8, 2024
- Simon
Table of Contents
- Simon
- S100 Rocker iO for Dimmer
- SKU: 10002020-13X
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Association LED
- Parameter 10: Delay ON
- Parameter 11: Activation Time
- Parameter 12: Behavior of LED in Repose
- Parameter 13: Lock Input
- Parameter 15: Reset Default
- Parameter 16: Delay OFF
- Parameter 19: Press Action
- Parameter 20: Identify
- Parameter 21: Load State
- Parameter 23: Calibration Required
- Parameter 27: Lock Hold Press
- Parameter 4: Set Time
- Parameter 5: Fade Time
- Parameter 6: Min Dimming %
- Parameter 7: Max Dimming %
- Parameter 9: Callibration
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Simon
S100 Rocker iO for Dimmer
SKU: 10002020-13X
Quickstart
This is a ****
Light Dimmer
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
When the pushbutton is released after a press of (2sec<T<10sec) the device
will send a NIF to include from Z-Wave network or perform an association with
other Z-Wave device.Central LED will Blink with 0,3 sec period to inform that
NIF can be send after release of pushbutton.This process does not perform a
default reset of configurations.Main LED will Blink with 0,3 sec period to
inform that NIF can be send after release of pushbutton.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Simon iO Dimmer is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec<T) the device will perform a factory default values operation, excluding it from network and reset the configuration parameters.Main LED will perform 1 Blink with 5 sec.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
When the pushbutton is released after a press of (2sec<T<10sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device.Central LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.This process does not perform a default reset of configurations.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
Exclusion
When the pushbutton is released after a press of (2sec<T<10sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.This process does not perform a default reset of configurations.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 3 | Z-Wave Plus Lifeline |
---|---|---|
2 | 20 | ctrl.CC Basic, Basic Report, Value 0x00 – 0x63 Report Dimming vaule |
after 2 seconds of last dimming change.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Association LED
Activates the Central LED. Configuration Used by Masters iO in order to
identify the devices associated to their Group2 during manual association
process.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Turns the LED OFF |
---|---|
1 – 255 | Turns the LED ON |
Parameter 10: Delay ON
Time that Dimmer delays the activation of the load after it receives an ON
request.This value must be set in hexadecimal format, and can accept these
values:0 – > ON Delay is 0.0×01…0x7F –> Delay ON is from 1 to 127 seconds. (1
second resolution)0x80…0xfE–> Delay ON is from 1 to 127 seconds. (1 minute
resolution)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | ON Delay is 0 seconds |
---|---|
1 – 127 | ON Delay is set in seconds from 1 to 127 seconds |
128 – 254 | ON Delay is set in minutes from 1 to 127 minutes |
Parameter 11: Activation Time
Time that Dimmer activates of the load after it turns the load ON.This value
must be set in hexadecimal format, and can accept these values:0 – >
Activation Time is 0.0×01…0x7F –> Activation Time is from 1 to 127 seconds. (1
second resolution)0x80…0xfE–> Activation Time is from 1 to 127 seconds. (1
minute resolution)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Activation Time is 0 seconds |
---|---|
1 – 127 | Activation Time is set in seconds from 1 to 127 seconds |
128 – 154 | Activation Time is set in minutes from 1 to 127 minutes |
Parameter 12: Behavior of LED in Repose
Sets the Left and Right Leds to 20% in order to find the device and the
touch areas at night.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Left and Right LEDs OFF |
---|---|
1 – 255 | Left and Right LEDs ON at 20percent |
Parameter 13: Lock Input
Locks the local control of the sunblind. This configuration does not
modifies the control via Z-Wave.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Local action enabled |
---|---|
1 – 255 | Local action locked |
Parameter 15: Reset Default
Write only parameter used to restore configurations or perform a completely
restore default.
Size: 2 Byte, Default Value: 0
SettingDescription
17170 | Configuration values are restored |
---|---|
39015 | Factory reset. |
Parameter 16: Delay OFF
Time that Dimmer delays the deactivation of the load after it receives an
OFF request.This value must be set in hexadecimal format, and can accept these
values:0 – > Delay OFF is 0.0×01…0x7F –> Delay OFF is from 1 to 127 seconds.
(1 second resolution)0x80…0xfE–> Delay OFF is from 1 to 127 seconds. (1 minute
resolution)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | OFF Delay is 0 seconds |
---|---|
1 – 127 | OFF Delay |
128 – 254 | OFF Delay is set in minutes from 1 to 127 minutes |
Parameter 19: Press Action
Defines the action to be performed when key is pressed.
Size: 1 Byte, Default Value: 5
SettingDescription
0 | When short press, the device toggles the load. The Slider does not work. |
---|---|
1 | When short press, the device turns ON the load. The Slider does not work. |
2 | When short press, the device turns OFF the load. The Slider does not works. |
4 | When short press, the device turns ON the load. When hold press from |
2seconds to 10seconds device turns OFF the load. The Slider does not works
with this configuration, the device will not send the Node Info neither Show
the LEDs feedback with this press action. The Slider does not work.
5| When short press, the device toggles the load. The Slider dims the load
when it is ON.
Parameter 20: Identify
Write only value that performs a fast blink on Central LED during 5 seconds
in order to identify the device when it is installed in a multiple frame.
Size: 1 Byte, Default Value: 0
SettingDescription
1 – 255 | Central LED performs a fast blink |
---|
Parameter 21: Load State
Read only 2 Byte configuration parameter used to read the dimmer state.Byte
0 is used to know the load state ON or OFF.0 Dimmer is OFF.1 Dimmer is ON.Byte
1 is used to Know the last active dimming percentage.
Size: 2 Byte, Default Value: 0
SettingDescription
1 – 99 | Load is OFF and las timming value is from 1% to 99% |
---|---|
256 – 355 | Load is ON Dimmed at 1% to 99% |
Parameter 23: Calibration Required
Read only configuration used to know is device needs to be calibrated in
order to work properly.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Device is calibrated |
---|---|
255 | Calibration must be performed |
Parameter 27: Lock Hold Press
Locks the major part of Hold press effects in order to avoid undesired
callibrations, Z-Wave changes or restores Default.0xFF Hold Press from 2sec to
20 sec does not performs a Node infoHold Press of 10 to 15 does not performs a
automatic callibrationHold press of 15 to 30 does not changes the sunblind or
awing reportsHold press of 30sec restores configuration except Lock Hold
Press, and sends a Node info in order to add or remove from Z-Wave Network
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Hold Press is available |
---|---|
1 – 255 | Hold Press from 2sec to 20 sec does not performs a Node info,Hold |
Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network
Parameter 4: Set Time
Sets the u0022Set Timeu0022 that will take the Dimmer to go from 0% to
100%This value must be set in hexadecimal format, and can accept these
values:0 – > Set Time is 0.0×01…0x7F –> Set Time is from 1 to 127 seconds. (1
second resolution)0x80…0xfE–> Set Time is from 1 to 127 seconds. (1 minute
resolution)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Sets Time is 0 |
---|---|
1 – 127 | Set Time is set in seconds from 1 to 127 minutes |
128 – 254 | Set Time is set in minutes from 1 to 127 minutes |
Parameter 5: Fade Time
Sets the u0022Fade Timeu0022 that will take the Dimmer to go from 100% to
0%This value must be set in hexadecimal format, and can accept these values:0
– > Fade Time is 0.0×01…0x7F –> Fade Time is from 1 to 127 seconds. (1 second
resolution)0x80…0xfE–> Fade Time is from 1 to 127 seconds. (1 minute
resolution)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Fade Time is 0 seconds |
---|---|
1 – 127 | Fade Time is set in seconds from 1 to 127 seconds |
128 – 254 | Fade Time is set in minutes from 1 to 127 minutes |
Parameter 6: Min Dimming %
Relative adjust used to set the minimum regulation value. This adjust is
done in reference to internal values, accepted dimming values will always be
from 1 to 0x63.Minimum Value must be < than Maximum Value.
Size: 1 Byte, Default Value: 1
SettingDescription
1 – 98 | minimum internal dimming value |
---|
Parameter 7: Max Dimming %
Relative adjust used to set the maximum regulation value. This adjust is
done in reference to internal values, accepted dimming values will always be
from 1 to 0x63.Maximum Value must be > then Minimum Value.
Size: 1 Byte, Default Value: 100
SettingDescription
2 – 99 | maximum internal dimming value |
---|
Parameter 9: Callibration
Write only configuration used to request the automatic adjust of UP and DOWN
times.
Size: 1 Byte, Default Value: 0
SettingDescription
255 | Sunblind starts its callibration process |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:78.59:70.48 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18026010 |
Z-Wave Product Id | 0x0267.0x0007.0x0000 |
Neutral Wire Required | ok |
Supported Meter Type | Electric Energy |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable LEDDimmable MLV |
(Magnetic)Incandescent
Firmware Updatable| Updatable by Professional/Technician
Frequency| XXfrequency
Maximum transmission power| XXantenna
Supported Command Classes
- Association Grp Info V3
- Association V2
- Basic
- Configuration V2
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Meter V4
- Powerlevel
- Switch Multilevel V3
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.