NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide

June 4, 2024
NODON

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide

Reference: SIN-2-FP-01
Power supply: 230V AC ~ 50Hz
Consumption: <1W
Heater maximum power: 3680 W
Metering of Instant power (W) and cumulated
Energy (Wh) – compatible home automation gateway needed (see the “Support” section on nodon.fr)
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +10dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Profile): D2-01-0C
Dimensions: 41 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 29 g
Warranty: 2 years

USE CAUTIONS

  • Never use the device if it is not correctly installed and placed inside a connecting box in conformity with the current norms.
  • Keep the product far away from liquids.

DETAILED USER GUIDE

Directly access the detailed user guide on the Support section on nodon.fr/en/technicalsupport/

https://nodon.fr/en/technical-support

CONTACT
NodOn SAS 121 rue des Hêtres 45590 St CYR EN VAL (FRANCE)

AFTER SALES SERVICE
nodon.fr/en/ “support” section support@nodon.fr

APPROVALS AND CERTIFICATIONS

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - APPROVALS AND
CERTIFICATIONS

DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid any risk of electrocution. This relay switch is designed to be used power up, a wrong installation can create a fire or an electric shock. If you are not confident about electrical installation, please ask a professional. The relay switch must be installed and connected carefully following the instructions of this user guide. We will not be responsible for any loss or damage resulting from a no respect of the instructions of this user guide. Cut the power supply before any operation and don’t do any modification if the LED is still ON.

INSTALLATION

Nod On Pilot Wire Heating Module allows to connect any type of pilot wire heater to a compatible Endogean network. Thanks to its compact size, the Pilot Wire Heating Module can be installed behind the grommet of the pilot wire heater.

TIP Add the Multifunction Relay Switch to the electric panel with Nod On DIN Rail Box.
Optional accessory

MODULE INPUTS/OUTPUTS

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - MODULE
INPUTS

Each terminal can accept a cable of 2.5mm² maximum, stripped of 8mm.

INSTALLATION DIAGRAM

  1. NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - Figure 1 Cut the power supply.

  2. Dismantle the grommet connecting your pilot wire heater.

  3. Cable the module according to diagram figure 1.
    ⚠ Warning: Make sure the pilot wire of your heater is well connected on the FP terminal before turning the power supply back ON.

  4. Reinstall the grommet.

  5. Turn the power supply back ON.

USE

During the first power up, the module default state is “Comfort” and the LED is green.

To change the mode, press briefly once on the button.

*Incrementation of the 4 module’s modes:**

The module LED will blink to confirm the activation of the next mode:

Comfort → Eco: LED blinks orange once
Eco → No Frost: LED blinks orange twice
No Frost → Stop: LED blinks orange 3 times
Stop → Comfort: LED blinks orange 4 times

*Note: Used with a home automation gateway, 6 modes are available: Comfort, Comfort -1°C, Comfort -2°C, Eco, No Frost and Stop. To change the mode, follow the instructions of your home automation gateway.

PAIRING PROCEDURE

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - PAIRING
PROCEDURE NODON
SIN-2-FP-01 Pilot Wire Heating Module User Guide - PAIRING
PROCEDURE

Note: if the LED blinks orange during the pairing procedure, it means that more than 22 controllers are paired and that no more controller can be paired. You must remove one controller to add a new one.

CONTROLLER USE

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - CONTROLLER
USE NODON SIN-2-FP-01 Pilot
Wire Heating Module User Guide - CONTROLLER USE

USE OF YOUR SOFT BUTTON

To pair your Soft Button with the module

  1. Launch the module pairing mode (see “Pairing Procedure”)
  2. You have now 30 seconds to pair your Soft Button by doing 5 brief consecutive presses on the button.
  3. The LED of the module will blink green twice, confirming the pairing of the two devices.

NODON SIN-2-FP-01 Pilot Wire Heating Module User Guide - USE OF YOUR SOFT
BUTTON

PAIRING WITH A HOME AUTOMATION GATEWAY

For more details on how to pair a home automation gateway or other compatible products, please consult the “Support” section on nodon.fr/en/

UNPAIRING PROCEDURE

Do the same procedure as pairing (see “Pairing procedure”).

RESET PROCEDURE

Module must be power supplied.

  1. Press more than 5 seconds on your module’s button. The LED blinks orange.
  2. Press once again the button (short press) to confirm the reset. If the reset is correct, the LED blinks alternatively in red and green and stays green. Start again if necessary.
  3. Your module has now its original settings.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NODON User Manuals

Related Manuals