Reference: SIN-2-FP-01
Power supply: 230V AC ~ 50Hz
Consumption: <1W
Heater maximum power: 3680 W
Metering of Instant power (W) and cumulated
Energy (Wh) – compatible home automation gateway needed (see the “Support”
section on nodon.fr)
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +10dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Profile): D2-01-0C
Dimensions: 41 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 29 g
Warranty: 2 years
USE CAUTIONS
- Never use the device if it is not correctly installed and placed inside a connecting box in conformity with the current norms.
- Keep the product far away from liquids.
DETAILED USER GUIDE
Directly access the detailed user guide on the Support section on nodon.fr/en/technicalsupport/
https://nodon.fr/en/technical-support
CONTACT
NodOn SAS 121 rue des Hêtres 45590 St CYR EN VAL (FRANCE)
AFTER SALES SERVICE
nodon.fr/en/ “support” section
support@nodon.fr
APPROVALS AND CERTIFICATIONS
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID
ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid any risk of
electrocution. This relay switch is designed to be used power up, a wrong
installation can create a fire or an electric shock. If you are not confident
about electrical installation, please ask a professional. The relay switch
must be installed and connected carefully following the instructions of this
user guide. We will not be responsible for any loss or damage resulting from a
no respect of the instructions of this user guide. Cut the power supply before
any operation and don’t do any modification if the LED is still ON.
INSTALLATION
Nod On Pilot Wire Heating Module allows to connect any type of pilot wire heater to a compatible Endogean network. Thanks to its compact size, the Pilot Wire Heating Module can be installed behind the grommet of the pilot wire heater.
TIP Add the Multifunction Relay Switch to the electric panel with Nod On
DIN Rail Box.
Optional accessory
MODULE INPUTS/OUTPUTS
Each terminal can accept a cable of 2.5mm² maximum, stripped of 8mm.
INSTALLATION DIAGRAM
-
Cut the power supply.
-
Dismantle the grommet connecting your pilot wire heater.
-
Cable the module according to diagram figure 1.
⚠ Warning: Make sure the pilot wire of your heater is well connected on the FP terminal before turning the power supply back ON. -
Reinstall the grommet.
-
Turn the power supply back ON.
USE
During the first power up, the module default state is “Comfort” and the LED is green.
To change the mode, press briefly once on the button.
*Incrementation of the 4 module’s modes:**
The module LED will blink to confirm the activation of the next mode:
Comfort → Eco: LED blinks orange once
Eco → No Frost: LED blinks orange twice
No Frost → Stop: LED blinks orange 3 times
Stop → Comfort: LED blinks orange 4 times
*Note: Used with a home automation gateway, 6 modes are available: Comfort, Comfort -1°C, Comfort -2°C, Eco, No Frost and Stop. To change the mode, follow the instructions of your home automation gateway.
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it means that more than 22 controllers are paired and that no more controller can be paired. You must remove one controller to add a new one.
CONTROLLER USE
USE OF YOUR SOFT BUTTON
To pair your Soft Button with the module
- Launch the module pairing mode (see “Pairing Procedure”)
- You have now 30 seconds to pair your Soft Button by doing 5 brief consecutive presses on the button.
- The LED of the module will blink green twice, confirming the pairing of the two devices.
PAIRING WITH A HOME AUTOMATION GATEWAY
For more details on how to pair a home automation gateway or other compatible products, please consult the “Support” section on nodon.fr/en/
UNPAIRING PROCEDURE
Do the same procedure as pairing (see “Pairing procedure”).
RESET PROCEDURE
Module must be power supplied.
- Press more than 5 seconds on your module’s button. The LED blinks orange.
- Press once again the button (short press) to confirm the reset. If the reset is correct, the LED blinks alternatively in red and green and stays green. Start again if necessary.
- Your module has now its original settings.
References
- Fabricant domotique OBL - OEM - ODM pour la Maison Connectée
- Smarte Wohnungen & Häuser - OEM ODM OBL Lösungen für IoT Produkte
- technische Unterstützung für NodOn | technische Dokumentationen, Lernprogramme, Anwendungsbeispiele
- Smart Home & Building - OEM ODM OBL solutions for IoT products
- Technical Support NodOn | Product documentation, tutorial, use cases
- Soporte técnico NodOn | Documentación del producto, tutorial, caso de uso
- Supports Archive - NodOn
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>