NODON SIN-2-2-01 On Off Lighting Relay Switch User Guide
- June 4, 2024
- NODON
Table of Contents
NODON SIN-2-2-01 On Off Lighting Relay Switch
ON/OFF LIGHTING
RELAY SWITCH
-
Reference: SIN-2-2-01
-
Power supply: 230V AC ~ 50Hz
-
Switching capabilities: 230V AC – 2 x 5A
-
Consumption: <1W
-
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads -
Radio frequency range: 868.0 to 868.6 Mhz
-
RF power max: +3dBm
Range: up to 30m indoor -
Operational temperature: -10°C to 40°C
-
Protection rating: IP 30
Pairing: up to 22 controllers -
EEP (EnOcean Profile): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h) -
Weight: 34 g
-
Warranty: 2 years
USE CAUTIONS
- Never use the device if it is not correctly installed and placed inside a connecting box in conformity with the current norms.
- Keep the product far away from liquids.
DETAILED
USER GUIDE
Directly access the detailed user guide on the Support section on nodon.fr/en/technical support/
APPROVALS AND CERTIFICATIONS
Hereby, NodOn SAS declares that this radio equipment is conform to the RED directive 2014/53/UE. The integral text of the EU declaration of conformity is available at the following online address: nodon.fr/en/ ”support” section.
The presence of this symbol on a product indicates that this one is conform to the European directive 2012/19/UE. Find out more about the provisions in force in your region regarding the separate collection of electrical and electronical devices. Respect the local rules and do not throw out the product with common domestic wastes. The correct rejection of ancient products allows to preserve the environment and health
- This product must be used indoor only.
- This product is conform to EnOcean radio protocol.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID
ANY RISK OF ELECTROCUTION. Directly cut the power supply from the breaker box
to avoid any risk of electrocution. This relay switch is designed to be used
power up, a wrong installation can create a fire or an electric shock. If you
are not confident about electrical installation, please ask a professional.
The relay switch must be installed and connected carefully following the
instructions of this user guide. We will not be responsible for any loss or
damage resulting from a nonrepeat of the instructions of this user guide. Cut
the power supply before any operation and don’t do any modification
if the LED is still ON.
INSTALLATION
Thanks to its small size, the ON/OFF Lighting Relay Switch can be installed anywhere in the wall or the ceiling (behind an existing wal switch, in a false ceiling, etc…).
TIP
- Add the ON/OFF Lighting Relay Switch to the electric panel with NodOn DIN Rail Box*.
RELAY SWITCH INPUT/OUTPUT
- Terminal for the Neutral
- L Terminal for the Line
- Input terminal for the wired switch 1*
- Input terminal for the wired switch 2*
- Output 1 (controlled by )
- Output 2 (controlled by )
Each terminal can accept a cable of 2.5mm² maximum, stripped of 8mm.
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE OR TWO LIGHTS
*Wired switch optional (see the installation diagrams section)
- Cut the power supply
- Dismantle the wired switch controlling the light(s) you want to connect.
- Install the ON/OFF Lighting Relay Switch according to diagram figure 1.
- Reinstall the wired switch.
- Turn the power supply back ON.
AUTO-DETECTION OF SWITCH TYPE
After turning the power supply ON, do a single push on the wired wall
switch. The relay switch has an auto-detection system to automatically detect
the type of wired wall switch (rocker or push-button) wired at the input.
Note: The same configuration is applied for both inputs ( and ). It is
not possible to combine a rocker switch with a push-button. To perform a new
auto-detection, the ON/OFF Lighting Relay Switch must be manually reset (see
reset procedure).
PAIRING PROCEDURE
To add a remote or a wall switch or the Soft Button (EnOcean compatible) you must enter the pairing mode, your light must be switched OFF.
Relay switch must be power supplied.
Two modes:
- From the module
Launch the pairing by doing 3 consecutive presses on the relay switch button. The LED blinks red.
- **From the wired wall switch
**
-
Action the wired wall switch 3 times (in less than a second). The lighting connected in blinks, meaning that the channel 1 ( / ) is in “pairing/unpairing mode
-
You have 30 seconds to pair your controller by briefly pressing (in less than a second) on the button of your choice, this one will turn the light ON for the channel 1, the opposite button will turn it OFF
-
The LED of the relay switch will blink green twice, confirming the pairing of the two devices
-
You have now 30 seconds to pair your Soft Button by doing 5 brief consecutive presses on the button.
-
The light stops to blink, confirming the pairing of the two devices
Two modes
-
1. 1. From the relay switch
- Launch the pairing by doing 3 consecutive presses on the relay switch button. The LED blinks red. Wait 1 second and do a new press on the relay switch button.
-
From the wired wall switch
- Press the wall switch 3 times (in less than a second). Wait 1 second and do a new press on the wall switch. The light connected in blinks, meaning that the channel 2 is in “Pairing/Unpairing” mode.
Continue with steps 2 and 3a/3b to pair your controller.
Note : if the LED blinks orange during the pairing procedure, it means
that more than 22 controllers are paired and that no more controller can be
paired. You must remove one controller to add a new one.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
Types of press | Action |
---|---|
Single press | Reversal |
Double press | ON |
Long press | OFF |
PAIRING WITH A HOME AUTOMATION GATEWAY
For more details on how to pair a home automation gateway or other compatible products, please consult the “Support” section on nodon.fr/en/
UNPAIRING PROCEDURE
Do the same procedure as pairing (see “pairing procedure”) and takes care of pressing the button chosen to control your gate/ garage door/electric latch or your electrical outlet.
RESET PROCEDURE
Relay switch must be power supplied.
- Press more than 5 seconds on your module’s button. The LED blinks orange.
- Press once again the button (short press) to confirm the reset. If the reset is correct, the LED blinks alternatively in red and green and stays green. Start again if necessary.
- Your module has now its original settings
References
- Fabricant domotique OBL - OEM - ODM pour la Maison Connectée
- Smart Home & Building - OEM ODM OBL solutions for IoT products
- Technical Support NodOn | Product documentation, tutorial, use cases
- Fabricante domótico OBL - OEM - ODM para el Hogar Conectado
- Charges compatibles / Compatible loads