NODON SIN-4-RS-20 Zigbee Roller Shutter Relay Switch User Guide

June 6, 2024
NODON

USER GUIDE
ZIGBEE ROLLER SHUTTER RELAY SWITCH

Reference: SIN-4-RS-20
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC – 3A
Consumption: <1W
Maximum engine power: 280W
Max – 60 Nm Max
List of compatible motors available on www.nodon.fr/loads
R F Protocol: Zigbee 3.0
Radio frequency range: 2.4Ghz
RF power Max: +10dBm
Range: up to 40m indoor
Operational temperature: -20°C to 60°C
Protection rating: IP 20
Dimension: 40 mm (l) x 44 mm (L) x 16,9 mm (h)
Weight: 34 g
Warranty: 2 years

USE CAUTIONS

  • Never use the device if it is not correctly installed and placed inside a connecting box in conformity with the current norms.
  •  Keep the product far away from liquids.

DETAILED USER GUIDE
Directly access the detailed user guide on the Support section on www.nodon.fr/en/support/zigbee-roller-shutter- relayswitch
CONTACT
NodOn SAS 121 rue des Hêtres 45590 St CYR EN VAL (FRANCE)

SAV
www.nodon.fr/en “support” section [email protected]

APPROVALS AND CERTIFICATIONS

Hereby, NodOn SAS declares that this radio equipment is conform to the RED directive 2014/53/UE. The integral text of the EU declaration of conformity is available at the following online address: www.nodon.fr “support” section.
The presence of this symbol on a product indicates that this one is conform to the European directive 2012/19/UE. Find out more about the provisions in force in your region regarding the separate collection of electrical and electronical devices. Respect the local rules and do not throw out the product with common domestic wastes. The correct rejection of ancient products allows to preserve the environment and health.
This product must be used indoor only.
This product is conform to Zigbee radio protocol.

DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid any risk of electrocution. This relay switch is designed to be used power up, a wrong installation can create a fire or an electric shock. If you are not confident about electrical installation, please ask a professional. The relay switch must be installed and connected carefully following the instructions of this user guide. We will not be responsible for any loss or damage resulting from a nonrespect of the instructions of this user guide. Cut the power supply before any operation and don’t do any modification if the LED is still ON.

INSTALLATION

Thanks to its compact size, the Zigbee Roller Shutter Relay Switch can be installed in a connecting box or behind the wall switch which controls the roller shutter or motorized awning.

TIP

Add the Zigbee Roller Shutter Relay
Switch to the electric panel with NodOn DIN Rail Box.
Optional accessory

RELAY SWITCH INPUT/OUTPUT

| Terminal for the Neutral
---|---
| Terminal for the Line
| Input terminal for the wired switch “up”
| Input terminal for the wired switch “down”

| Engine output terminal “up”
| Engine output terminal “down”

Each terminal should be installed with a cable from 1.5mm² to 4mm² maximum, stripped of 8mm.
*Wired switch optional.

INSTALLATION DIAGRAM

*Wired switch optional.

  1. Cut the power supply.
  2. Disassemble the wired wall switch which controls the roller shutter/awning you want to connect.
  3. Wire the Relay Switch according to the diagram figure 1.
  4. Reassemble the wired wall switch.
  5. Turn the power back ON.

Discover the other installation diagrams in the “support” section on www.nodon.fr/en

AUTO-DETECTION OF SWITCH TYPE
After turning the power supply ON, do a single push on the wired wall switch to bring the roller shutter half-height. The Relay Switch has an auto- detection system to automatically detect the type of wired wall switch (rocker or push-button) wired at the input.

INSTALLATION DIAGRAMS

Find all the installation diagrams on the “support” section on www.nodon.fr/en

CALIBRATION OF THE ROLLER SHUTTER RELAY SWITCH

Relay Switch must be power supplied.

Note: The Relay Switch Led blinks green, meaning the calibration has well started.

  1. Do 5 short presses.

  2. The roller shutter/awning confirms the auto-calibration by performing a complete cycle “up/down/up” **.

Cancel the calibration: Perform 5 brief presses. From the wired switch, press once on the switch.
** If the cycle is reversed (down/up/down), switch and

ADDING TO A ZIGBEE NETWORK

When power is turned ON, the relay switch Led will blink orange, looking to join a Zigbee network. Go to your Zigbee gateway app to activate the relay switch detection. See the compatible home automation gateways on www.nodon.fr/en/support

If the relay switch has correctly joined the network, the Led becomes green. The relay switch is ready for use.

If the relay switch hasn’t joined a network within 15 minutes, the Led becomes orange. Do a brief press on the relay switch button and start again.

UNPAIRING PROCEDURE

To remove the module from its network, perform a Module Reset (see “Reset Procedure”).

RESET PROCEDURE

Relay switch must be power supplied.

  1. Press more than 5 seconds on your module’s button. The Led blinks orange.
  2. Press the button again (short press) to validate the reset. If the reset is successful, the Led flashes red and green alternately, then flashes orange. Repeat if necessary.
  3. Your module has returned to its original configuration and is ready to join a new Zigbee network.

SIN-4-RS-20_UG_V1

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>