INSTALLATION
3.1 SELECT THE BEST LOCATION
-
To prevent vibration and noise, make sure the unit is installed securely and firmly.
-
Install the unit where the sunlight does not shine directly on the unit.
-
The outside of the cabinet must extend outward for atleast 11″ and there should be no obstacles, such as a fence or wall, within 20″ from the back of the cabinet because it will prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. CAUTION All side louvers of the cabinet must remain exposed to the outside of the structure. -
Install the unit a little slanted so the back is slightly lower than the front (about /2″). This will help force condensed water to the outside.
-
Install the unit from the bottom about 30″~60″ above the floor level.
3.2 CHECK OF INSTALLATION
The setting conditions must be checked prior to initial starting.
The undermentioned items are especially important checking points when the
installation is finished.
- Grounding wire (Green or Green and Yellow) is provided in the power cord. The green wire must be grounded.
- Connect to a single-outlet 15A circuit.
- To avoid vibration or noise, make sure the air conditioner is installed securely.
- Avoid placing furniture or draperies in front of the air inlet and outlet. 3.3. HOW TO DRAIN
(When using drain pipe)
The air conditioner must be installed horizontally or tilted slightly to the outside for proper water drainage.
On exceptionally hot and humid days the air conditioner may overflow condensed water.
If the air conditioner is used in a hot and high humidity zone, exchange the ¥ LHOLE RUBBER for the ¥MDRAIN PIPE.(See figure 18, figure 19.)
3.4 HOW TO INSTALL
3.4.1 WHEN USING GASKET
- WINDOW (WIDTH-A, HEIGHT-B)
- GASKET
- WALL
- DETAILS 5.1 x 30 ROUND HEAD WOOD SCREWS
A| B| C| D| E| F| G| H| J| K
---|---|---|---|---|---|---|---|---|---
495mm| 366mm| 250mm| 30mm| 0-25mm| OVER 420mm| 12mm| 32mm| 5-10mm| 0-5mm
(191/2″)| (147/16)| (10″)| (11/16″)| (0-1″)| (OVER 1617/32″)| (1/2″)| (11/4″)| (3/16″-3/a”)| (0-3/16″)
3.4.2 WHEN USING INSTALLATION KITS
A. WINDOW REQUIREMENTS
This unit is designed for installation in standard double hung windows with
actual opening widths from 22″ to 36″.
The top and bottom window sash must open sufficiently to allow a clear
vertical opening of 15″ from the bottom of the upper sash to the window stool.
B. INSTALLATION KITS CONTENTS
NO. | NAME OF PARTS | Q’TY |
---|---|---|
1 | FRAME CURTAIN | 2 |
2 | SILL SUPPORT | 2 |
3 | BOLT | 2 |
4 | NUT | 2 |
5 | SCREW(TYPE A) | 16 |
6 | SCREW(TYPE B) | 3 |
7 | SCREW(TYPE C) | 5 |
8 | FOAM-STRIP | 1 |
9 | UPPER GUIDE | 1 |
10 | FOAM-PE | 1 |
11 | FRAME GUIDE | 2 |
12 | WINDOW LOCKING BRACKET | 1 |
13 | FOAM-PE | 1 |
SUGGESTED TOOL REQUIREMENTS
SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL
PREPARATION OF CHASSIS
-
Remove the screws which fasten the cabinet at both sides and at the back.
-
Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet.
-
Cut the window sash seal to the proper length.
Peel off the backing and attach the foam-pe to the underside of the window sash. -
Remove the backing from the top upper guide Foam PE and attach it to the bottom of the upper guideQ.
-
Attach the upper guide onto the top of the cabinet with 3 type A screws.
-
Insert the frame guides zinto the bottom of the cabinet.
-
Insert the Frame Curtain into the upper guide and frame guides
-
Fasten the curtains to the unit with 4 Type A screws.
CABINET INSTALLATION
-
Open the window. Mark a line on center of the window stool(or desired air conditioner location).
Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the window stool. -
Pull the bottom window sash down behind the upper guide until it meets.
NOTE :
+ Do not pull the window sash down so tightly that the movement of Frame Curtain is restricted. -
Loosely assemble the sill support using the parts in Figure 22.
-
Select the position that will place the sill support near the outer most point on sill (See Figure 23)
NOTE: Be careful when you install the cabinet (frame guides are broken so easily). -
Attach the sill support to the cabinet track hole in relation to the selected position using 2 Type A screws in each support(See Figure 23).
-
The cabinet should be installed with a very slight tilt(about ‘/2″”) downward toward the outside (See Figure 24).
Adjust the bolt and the nut of sill support for balancing the cabinet. -
Attach the cabinet to the window stool by driving the screws (Type B: Length sixteen millimeters and below.) through the front angle into window stool.
-
Pull each Frame curtain fully to each window sash track, and repeat step 2.
-
Attach each Frame curtain the window sash using screws (Type C).(See Figure 25) CAUTION : DO NOT DRILL A HOLE IN THE BOTTOM PAN.
The unit is designed to operate with approximately 1/2″ of water in bottom pan. -
Slide the unit into the cabinet.(See Figure 26)
CAUTION : For security purpose, reinstall screws(Type A) at cabinet’s sides. -
Cut the foam-strip to the proper length and insert between the upper window sash and the lower window sash. (See Figure 27)
-
Attach the window locking bracket with a type C screw. (See Figure 28)
-
Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Figure 29)
-
Lift the inlet grille and secure it with a type A screw through the front grille. (See Figure 30)
-
Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet.
3.5 HOW TO USE THE
REVERSIBLE INLET GRILLE
-
If you want to pull out the filter upward, open the inlet grille slightly. Turn inside out the front grille.
Disassemble the inlet grille from the front grille with separating the hinged part by inserting a “—” type screw-driver tip.
Rotate the inlet grille 180 degrees and insert the hooks into the lower holes of front grille.
Then, insert the filter. (See Figure 32, 33) -
Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place.
(See Figue 34) -
Lift the inlet grille and secure it with a type A screw through the front grille. (See Figure 35)
-
If you want to pull out the filter downward, use the reversible inlet grille without change.
(The grille is already assembled for that way.)