nodon SIN-4-2-20-UG Zigbee On-Off Lighting Relay Switch User Guide
- June 4, 2024
- NODON
Table of Contents
nodon SIN-4-2-20-UG Zigbee On-Off Lighting Relay Switch
ZIGBEE ON/OFF LIGHTING RELAY SWITCH
- Reference: SIN-4-2-20
- Power supply: 230V AC ~ 50Hz
- Switching capabilities: 230V AC – 2 x 3A
- Consumption: <1W
- Maximum output power: 2 x 690W – Integrated zero crossing RF Protocol: Zigbee 3.0
- Radiofrequency range: 2.4Ghz
- RF power max : +10dBm
- Range: up to 40m indoor
- Operational temperature: – 20°C to 60°C
- Protection rating: IP 20
- Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h) Weight: 34 g
- Warranty: 2 years
USE CAUTIONS
- Never use the device if it is not correctly installed and placed inside a connecting box in conformity with the current norms.
- Keep the product far away from liquids.
DETAILED USER GUIDE
Directly access the detailed user guide on the Support section on nodon.fr/en/technicalsupport/
APPROVALS AND CERTIFICATIONS
Hereby, NodOn SAS declares that this radio equipment is conform to the RED
directive 2014/53/UE. The integral text of the EU declaration of conformity is
available at the following online address: nodon.fr/en/
”support” section.
Hereby, NodOn declares that the radio equipment type direct current motor
controller is in compliance with RER 2017 (SI 2017/1206). The full text of the
UK declaration of conformity is available at the following internet address:
nodon.fr/en/ ”support” section.
UK importer address
The presence of this symbol on a product indicates that this one is conform to the European directive 2012/19/UE. Find out more about the provisions in force in your region regarding the separate collection of electrical and electronic devices. Respect the local rules and do not throw out the product with common domestic waste. The correct rejection of ancient products allows preserving the environment and health
- This product must be used indoors only
- The device is used 20 cm or more from the human body.
- This product conforms to Zigbee radio protocol
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID
ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid any risk of
electrocution. This relay switch is designed to be used power up, a wrong
installation can create a fire or an electric shock. If you are not confident
about electrical installation, please ask a professional. The relay switch
must be installed and connected carefully following the instructions of this
user guide. We will not be responsible for any loss or damage resulting from a
nonrespect of the instructions of this user guide. Cut the power supply before
any operation and don’t do any modification if the LED is still ON
INSTALLATION
Thanks to its small size, the Zigbee ON/ OFF Lighting Relay Switch can be installed anywhere in the wall or the ceiling (behind an existing wall switch, in a false ceiling, etc…).
RELAY SWITCH INPUT/OUTPUT
Each terminal should be installed with a cable from 1.5mm² to 4mm² maximum, stripped of 8mm. Wired switch optional
INSTALLATION DIAGRAM FOR ONE OR TWO LIGHTS
Wired switch optional.
- Cut the power supply
- Dismantle the wired switch controlling the light(s) you want to connect.
- Install the ON/OFF Lighting Relay Switch according to diagram figure 1.
- Reinstall the wired switch.
- Turn the power supply back ON.
AUTO-DETECTION OF SWITCH TYPE
When you turn the power supply ON (via the electrical box for example) once
the relay switch is installed, it is necessary to perform a simple action
(single press on the button) on the wired switch(es). Automatic detection of
the type of switch (monostable or bistable) will then be performed.
INSTALLATION DIAGRAMS
Find all the installation diagrams on the “Support” section on nodon.fr/en/
ADDING TO A ZIGBEE NETWORK
- When power is turned ON, the relay switch Led will blink orange, looking to join a Zigbee network. Go to your Zigbee gateway app to activate the relay switch detection. See the compatible home automation gateways on nodon.fr/en/support
- If the relay switch has correctly joined the network, the Led becomes green. The relay switch is ready for use
- If the relay switch hasn’t joined a network within 15 minutes, the Led becomes orange. Do a brief press on the relay switch button and start again.
UNPAIRING PROCEDURE
To remove the module from its network, perform a Module Reset (see “Reset Procedure”).
RESET PROCEDURE
Relay switch must be power supplied.
- Press more than 5 seconds on your module’s button. The Led blinks orange.
- Press the button again (short press) to validate the reset. If the reset is successful, the Led flashes red and green alternately, then flashes orange. Repeat if necessary.
- Your module has returned to its original configuration and is ready to join a new Zigbee network.
CONTACT
NodOn SAS 121 rue des Hêtres 45590 St CYR EN (FRANCE)
AFTER-SALES SERVICE
nodon.fr/en/ “support” section support@nodon.fr
References
- Fabricant domotique OBL - OEM - ODM pour la Maison Connectée
- technische Unterstützung für NodOn | technische Dokumentationen, Lernprogramme, Anwendungsbeispiele
- Smart Home & Building - OEM ODM OBL solutions for IoT products
- Supports Archive - NodOn
- Technical Support NodOn | Product documentation, tutorial, use cases
- Soporte técnico NodOn | Documentación del producto, tutorial, caso de uso
- Supports Archive - NodOn
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>