Everspring Z-Wave Power Meter plus Switch – Type F EVR_AN1582 Manual
- June 8, 2024
- EVERSPRING
Table of Contents
- Everspring
- Z-Wave Power Meter plus Switch – Type F
- SKU: EVR_AN1582
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Everspring
Z-Wave Power Meter plus Switch – Type F
SKU: EVR_AN1582
Quickstart
This is a ****
On/Off Power Switch
for
Europe.
To run this device please connect it to your mains power supply.
Inclusion and Exclusion are confirmed by a tripple click of the button of the device.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The AN1582 is a pluggable switch that controls electrical loads connected to mains power using standard type F wall outlets. It can switch all electrical loads up to 3500 W and additionally measure the electrical power taken by this load (in Wh) and meters the electrical energy consumed (in kWh). The device is IP 20 rated and therefore, it only can be used in dry environments. The device is operated either wirelessly using Z-Wave or with a button on the device. A red LED indicates the switching status.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Tripple Click the button (same as for inclusion/exlusion) plus pushing the button again within 1 sec and hold it down for 5 sec.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The device can be plugged into every standard outlet (plug type F). Do not locate the Module facing direct sunlight, humid or dusty place. The suitable ambient temperature for the module is 0°C ~ 40°C.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Inclusion and Exclusion are confirmed by a tripple click of the button of the device.
Exclusion
Inclusion and Exclusion are confirmed by a tripple click of the button of the device.
Product Usage
Plug this module into a wall outlet near the load to be controlled. Plug the load into the module and switch the load to the ON position. To turn ON the module and the load plugged into it, press and release the ON/OFF button of the module.
The device is able to switch and measure any electric load up to 3500 W. Any load above 3500 W is considered as overloading. When overloading is detected the device will turn off the load, lock the local button and indicate the status by flashing the LED for 30 sec. Unplugging and replugging the module will reset the module to normal state. The electrical load can be switching using wireless commands and operating the local button. The LED inside the local button will indicate the switching status.
To access the metered and measure electric values a gateway with appropriate visualization is required.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
2 | 4 | Pressing button to switch other devices |
---|---|---|
1 | 1 | Send Alarm, Switch Report and Meter Report |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: True Period
This is the time the switching status needs to remain unchanged after a
change to cause the device to send out a status message
Size: 1 Byte, Default Value: 0a
SettingDescription
00 | Disable |
---|---|
01 – 78 | 10 * 100 ms = 1 sec |
Parameter 2: Send Out Basic Command
Enable or Disable the status message function when the local button press
changes the switching state
Size: 1 Byte, Default Value: 00
SettingDescription
00 | Disable |
---|---|
01 | Enable |
Parameter 3: Meter Report Period
The device will report its meter value within the interval set. Set to 0
will disable the autoreporting function.
Size: 2 Byte, Default Value: 0003
SettingDescription
0000 | Disabled |
---|---|
0001 – 0ca8 | Interval = Wert * 10 sec |
Technical Data
Dimensions | 0.0580000×0.1110000×0.0730000 mm |
---|---|
Weight | 151 gr |
Hardware Platform | ZM3102 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.01 |
Z-Wave Version | 02.40 |
Certification ID | ZC08-09100006 |
Z-Wave Product Id | 0060.0004.0002 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Basic
- Association
- Version
- Switch All
- Manufacturer Specific
- Configuration
- Meter
- Switch Binary
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>