Anolis Ambiane HP111 Surface Mount User Manual

June 8, 2024
ANOLiS

Anolis Ambiane HP111 Surface Mount

Attention

The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

  • The unit was designed for indoor use only.
  • Do not install the unit near highly inflammable liquids or materials.
  • Do not allow anything to rest on the unit.
  • Do not install the unit near an open flame.
  • Do not install the unit in dirty, dusty or badly ventilated location.
  • Avoid looking directly into the light beam at close range!
  • A ceiling (structure) intended for installation of the unit(s) must safely hold at least 5 times the weight of the unit(s) fastened on it.
  • Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.
  • The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
  • The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment.
  • Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.

Fixture exterior view

Anolis-Ambiane-HP111-Surface-Mount- \(2\)

Installation

The Ambiane HP111 Surface Mount must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Always switch off power supply of the control unit before connecting or disconnecting the control unit or the light unit.
The lower ceiling (or another structure) intended for installation of the Ambiane(s) HP111 Surface Mount must safely hold at least 5 times weight of the Ambiane(s) HP111 Surface Mount placed on it.

  1. Prepare a circular opening in the lower ceiling. Max. possible thickness of the lower ceiling material can be 20 mm.

  2. Place the control unit (1) above the ceiling through the ceiling opening and fasten it by means of two holes in the housing of the control unit and suitable fasteners.

  3. Install the terminal block (2) on the supply cable connect it to the PCB RB 3729 of the control unit (1).

  4. Install the terminal block (3) on the DMX cable and connect it to the PCB RB 3729 of the control unit (1).

  5. Install the terminal block (4) on the LED unit cable and connect it to the PCB RB 3729 of the control unit (1).

  6. Install another terminal blocks on cables according to requirements of current installation.
    Example of connection:Anolis-Ambiane-HP111-Surface-Mount-
\(5\)
    Note: The trimmer (7) allows you to set a light intensity (for secondary power only). This trimmer is accessible by aperture (5) in the cover of the control unit (1).

    • LED unit connection
      Connector| +| A| B|
      ---|---|---|---|---
      Function| LEDs +| Data A| Data B| LEDs –
      Colour of wire| Red| White| Blue| Black
    • Primary power connection
      Connector| Vcc| 0V
      ---|---|---
      Function| Power +| Power –
    • Secondary power connection
      Connector| Vcc| 0V
      ---|---|---
      Function| Power +| Power –

Recommended diameters of conductors with respect to distance between the Control unit and the power supply (e.g. Ambiane Power HP):

Distance/cable length 25 m 50 m 75 m 100 m
Diameters of conductors 0.5 mm2 1 mm2 1.5 mm2 2 mm2
  * DMX connection  
Connector D+ D- 0V
Function Data + Data- Data ground(shielding)
  * 0-10V connection  
Connector D+ 0V
Function +10V 0V
  * DMX connectors are used for 0-10V control  

The primary power input serves for a standard power (e.g. Ambiane Power HP).
The secondary power input serves for a backup power (in case that primary power failed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled. In case of primary power loss, the secondary power is enabled. If the fixture is supplied via the secondary power, the light output of the fixture is a white colour (3200K) and its light intensity can be set by the trimmer (7) accessible by aperture (5) in the cover of the control unit (1).

  1. Set the DIP switch (6) according to your operation mode. This DIP switch is accessible by aperture (5) in the cover of the control unit (1).
    The fixture can be controlled by one of the following methods: DMX 512

  2. Insert the LED unit (10) into the lower ceiling mounting hole (9).Anolis-Ambiane-HP111-Surface-Mount- \(6\)

  3. Spread the holders (11) and tighten them by means of two screws (12), use an Allen key 2.5.Anolis-Ambiane-HP111-Surface-Mount- \(7\)

Ring Louver installation
Snap the Ring Louver (13) into the LED unit (10).

DMX and DALI address setting and control

The DIP switch on the control PCB (RB3729) allows you to set DMX address and run a test light.

  • DIP 10 – if it is switched to ON=test light (the fixture lights at 3200K (for RGBW and TW version))
  • DIP 11 – has to be switched to OFF position to receive DMX 512 and DALI, position ON=0-10V control

Note: If DIP 11=OFF (fixture is controlled by DMX and DALI), the last coming command switches the fixture to the corresponding operation mode (DMX operation by a DMX command, DALI operation by a DALI command). E.g. the fixture stays in a DALI operation and last coming command is a DMX command which switches the fixture to DMX operation. Next command is a DALI command and switches the fixture to the DALI operation etc.
If you need the permanent DALI operation, you have to send a DALI command 8 to the fixture.

DMX control
The DMX start address, is the first channel used to receive instructions from the DMX controller. The address may be any channel from 1 to 512. DMX address can be set either by DIP switch or by RDM. DMX address set by RDM overwrites address set by DIP switch and vice versa. The green LED on PCB signals way of DMX address setting:

  • LED lights-DMX address is set by means of the DIP switch.
  • LED does not light-DMX address is set by means of RDM.

The DIP 11 has to be set to OFF position.
Example of DMX addresses:

DALI control
Addressing of the fixture has to be made by means of an external DALI controller.
If you need to start the permanent DALI control of the fixture (fixture will not respond to DMX commands), the external DALI controller has to send activating command (8=ON).
If you need to stop the permanent DALI control of the fixture, the external DALI controller has to send deactivating command (0=OFF).

0-10V control

DIP 11 has to be set in ON position. 0-10V operation has priority to DALI and DMX commands. The option is applicable for the PW and TD version of the Ambiane HP111 Surface mount only.

RDM

This fixture supports RDM operation. RDM (Remote Device Management) is a bi- directional communication protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and status monitoring.
RDM allows you to set a DMX address, select DMX mode, readout software version of the fixture etc. It is also used for fixture software update by means of the Robe Uploader.
RDM model ID for the Ambiane HP111 Surface mount is: 0x0114.

Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *  
DISC_MUTE *  
DISC_UN_MUTE *  
DEVICE_INFO     *
SUPPORTED_PARAMETERS     *
SOFTWARE_VERSION_LABEL     *
DMX_START_ADDRESS   * *
IDENTIFY_DEVICE   * *
DEVICE_MODEL_DESCRIPTION     *
MANUFACTURER_LABEL     *
DEVICE_LABEL   * *
DMX_PERSONALITY   ***** *****
DMX_PERSONALITY_DESCRIPTION     *****
RESET_DEVICE   *
SENSOR_VALUE   * *
SENSOR_DEFINITION     *
SLOT_INFO     *
SLOT_DESCRIPTION     *
DEFAULT_SLOT_VALUE     *
PARAMETER_DESCRIPTION     *

DMX protocols

Variant RGBW, version 1.1

Mode 1

Channel

| Mode 2

Channel

| Mode 3

Channel

| Mode 4

Channel

| Mode 5

Channel

| DMX

value

| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1| 0-255| Red Red LEDs saturation control (0–>100%)| proportional
–| –| 2| –| –| 0-255| Red Fine Red LEDs saturation control (0–>100%)| proportional
2| 2| 3| –| 2| 0-255| Green Green LEDs saturation control (0-100%)| proportional
–| –| 4| –| –| 0-255| Green Fine Green LEDs saturation control (0–>100%)| proportional
3| 3| 5| –| 3| 0-255| Blue Blue LEDs saturation control (0 –>100%)| proportional
–| –| 6| –| –| 0-255| Blue Fine Blue LEDs saturation control (0–>100%)| proportional
4| –| 7| –| 4| 0-255| White White LEDs saturation control (0–>100%)| proportional
–| –| 8| –| –| 0-255| White Fine White LEDs saturation control (0–>100%)| proportional
–| –| 9| 1|  |  | Green correction|
 |  |  |  | 0| Uncorrected white| step
 |  |  |  | 1-127

128

129-

255

| Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected white –> Plus green| proportional

step

proportional

–| –| 10| 2|  |  | Colour temperature correction (CTC)|
 |  |  |  | 0| No function (0=default)| step
 |  |  |  | 1-10| Tungsten dimming 2700 K| step
 |  |  |  | 11-20| Tungsten dimming 3200 K| step
 |  |  |  | 21-255| Colour temperature changing 2700 K–> 6500 K| proportional
–| –| 11| 3| 5| 0-255| Dimmer Light intensity coarse (0–>100%)| proportional
–| –| 12| –| 6| 0-255| Dimmer Fine Light intensity fine (0–>100%).| proportional

DMX mode has to be set by RDM.

Variant TW, version 1.1

Mode 1

Channel

| Mode 2

Channel

| DMX

value

| Function| Type of

control

---|---|---|---|---
1| –| 0-255| White colour selection White from 2700K–>4000K| proportional
–| 1| 0-255| Warm White Warm white LEDs saturation control (0–>100%)| proportional
–| 2| 0-255| Cool White Cool white LEDs saturation control (0–>100%)| proportional
2| 3| 0-255| Dimmer Light intensity (0–>100%)| proportional

Variant TD, PW version 1.1

Mode 1

Channel

| Mode 2

Channel

| DMX

value

| Function| Type of

control

---|---|---|---|---
1| 1| 0-255| Dimmer Light intensity coarse (0–>100%)| proportional
–| 2| 0-255| Dimmer Fine Light intensity (0–>100%)| proportional

Technical specifications

  • Nominal input voltage: 48V DC
  • Input voltage range: 44-50V DC
  • Max. power consumption: 75W
  • Light source: High Power LED module
  • Beam angle: 20°, 40°,60°, 80°
  • Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F °F)
  • Colour Variants: RGBW (W – 2700K or 4000K), PureWhite, Tunable White, Tungsten Dim
  • Colour Temperature of White: PW 2700 K or 4000K, TW 2700 – 4000K, TD 3200K
  • CRI: 90+
  • Control: DMX, DALI 2 , RDM, 0-10V
  • Settings/Addressing: DIP Switch, RDM
  • DMX channels (RGBW variant): 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5)
  • DMX channels (TW variant): 2 (Mode 1), 3 (Mode 2)
  • DMX channels (TD, PW variant): 2 (Mode 1), 2 (Mode 2)
  • Power supply (CE): Ambiane Power HP (48V/100W), Ambiane Power Rack
  • Power supply (US): Ambiane Power HP (48V/100W), Ambiane Power Rack US
  • Operating ambient temp. range: -20 °C / +40 °C (-4 °F / +104 °F)
  • Operating Temperature (LED unit): +75 °C @ Ambient +40 °C (167 °F @ Ambient 104 °F)
  • Total heat dissipation: 191 BTU/h (calculated)
  • Cooling: convection
  • Housing: High Pressure Die-Cast Aluminium Body
  • Weight (without control unit) :
    • Ambiane HP111 Surface mount 20° 2.6 kg/ 5.7 lbs
    • Ambiane HP111 Surface mount 40° 3.1 kg/ 6.8 lbs
    • Ambiane HP111 Surface mount 60° 2.5 kg/ 5.5 lbs
    • Ambiane HP111 Surface mount 80° 2.5 kg/ 5.5 lbs
  • Mounting Method: Pendant with 1 adjustable hanging wire
  • IC rating: Non-IC rated
  • Power connection: Connectors
  • DMX connection: Connectors
  • DALI connection: Connectors
  • LED unit connection: Connector
  • Protection factor (CE): IP20
  • Protection factor (US): Dry location only

Dimensions
mm [inch]

  • Ambiane HP 20° H = 302 mm [11 7/8 in.]
  • Ambiane HP 40° H = 298 mm [11 3/4 in.]
  • Ambiane HP 60° H = 285 mm [11 1/4 in.]
  • Ambiane HP 80° H = 271 mm [10 11/16 in

Anolis-Ambiane-HP111-Surface-Mount- \(11\)

Control unit

Included items

  • 1 x Ambiane HP111 Surface mount
  • 1 x Control unit
  • 1 x Set of cable connectors
  • 1 x User manual

Optional accessories
Ambiane Power HP (MeanWell ELG-100-48-3Y) (P/N 10064073) Ambiane Power Rack (P/N 10063951), black colour Ambiane Power Rack US (P/N 10063873), black colour Ring Louver for Ambiane HP111 Surface mount 20°

Cleaning and maintenance

Keep the fixture clean, especially light source and the ribbed heat sink. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.

Software update
The fixture has to be connected to power during software update.
Software update by means of the Robe Uploader
The ROBE Uploader is a software for automatized software update of Robe and Anolis fixtures. It can take advantage of RDM support.Anolis-Ambiane-HP111
-Surface-Mount- \(13\)

The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via the Robe Universal Interface/Robe Universal Interface WTX and a USB cable connected to the control PC with the Robe Uploader running. The fixtures have to be connected to power. The control PC should be connected to the Internet.

The Robe Uploader software and user manual is available at https://www.robe.cz/robe-uploader/ If you do the software update by means of the Robe Uploader, switching fixtures to the update mode (and from the update mode) is made automatically. Note: The Robe Uploader software cannot be used if fixtures are connected by means of DALI connection.

Disposing of the product
To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes.

June 16, 2022
Copyright © 2022 Robe Lighting – All rights reserved
All Specifications subject to change without notice
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici

QR code for user manual

Documents / Resources

| Anolis Ambiane HP111 Surface Mount [pdf] User Manual
Ambiane HP111 Surface Mount, Ambiane HP111, Surface Mount, Mount
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ANOLiS User Manuals

Related Manuals