INTRODUCTION
The QCC-6000 Card is required for audio system expansion (beyond 1 amplifier cage). It allows for remote audio cabinet expansion up 2000 feet. It supports up to 9 expansion cabinets on each node. Mount the QCC-6000 on the far right side of the audio card cage, refer to Figure 4. Use the rotary switch SW1 to set the card’s address. The card in the main cabinet should be 0. Set each card consecutively so that there are no gaps.
Figure 1 QCC-6000 Communications Card
Figure 2 Field Wiring between QCC-6000s Class B
The maximum wiring length between QCC-6000s is 2000 feet (610 m) (suitable wire gauge is 18 AWG). Refer to the FX-MNS-6000 manual LT-6683 for complete wiring details. Rotary Switch SW1is located in the top right hand corner as shown in Figure 1 above and is set starting from the address 0 to 9 for each expansion cabinet. Maximum 10 per node.
Figure 3 QCC-6000 Rotary Switch for Setting the Address
Figure 4 Mounting the QCC-6000 Communications Card on QMB-6000 Audio Card Cage